To get assistance with your HVAC and plumbing repairs, maintenance, and installations, look no further! To see what our satisfied customers think about our HVAC and plumber services in Pepin, WI, read our reviews below.
Completed comprehensive plumbing inspection of water heater installation, examining copper supply lines, gas connections, and associated components. Documented existing corrosion on copper piping with visible patina formation, verified proper installation of yellow flexible gas line with appropriate brass fittings and PVC connections, and assessed HVAC refrigeration system equipment including pressure gauges, hoses, and monitoring devices for proper operation and compliance with code requirements.
Completed comprehensive plumbing inspection of residential bathroom facilities. All fixtures, including toilet, were examined for proper operation, leaks, and potential issues. No immediate repairs required; system functioning within normal parameters.
Responded to recurring leak in geothermal zone valve that has required replacement twice in the past two years. Diagnosed active water leak at zone valve assembly and documented condition with photos showing corroded brass fittings and aged copper piping connections. Presented customer with repair options including replacement with standard plastic zone valve requiring periodic replacement every few years versus upgraded brass valve with potential noise concerns and no guaranteed improvement in longevity. Recommended maintaining current plastic valve specification and keeping spare unit on-site for future replacement due to straightforward installation process when proper valve is available.
Replaced complete toilet tank internal components on Gerber toilet including fill valve, flapper, and trip lever assembly due to malfunction. Provided estimate for bathroom sink drain repairs as requested.
Performed comprehensive furnace tune-up on older General Electric unit. Replaced dirty air filter with customer-supplied unit. Inspection revealed clean burners but dirty blower assembly and weak capacitor reading 3uf (rated 5uf). Conducted thorough heat exchanger inspection with photographic documentation, identifying areas of concern but no active compromises. Ran system for 10 minutes to verify operation; unit functioned properly with elevated supply temperatures likely due to blower contamination. Discussed equipment age, overall condition, and heat exchanger concerns with homeowner and family, providing visual documentation. Recommended obtaining estimates for blower motor/capacitor repair and full system replacement options for comparison.
Completed comprehensive whole-home duct cleaning for residential property with no pets present. Performed thorough cleaning of all HVAC ductwork throughout the system, removing accumulated dust, debris, and contaminants to improve air quality and system efficiency. Additionally serviced dryer vent system, discovering and removing significant lint buildup that posed a potential fire hazard and restricted airflow. All vents were cleaned and inspected to ensure proper ventilation and optimal performance of both HVAC and dryer systems.
Responded to no heat call on recently installed propane boiler. Upon arrival, determined system had shut down due to overheating caused by radiators becoming excessively hot while exterior doors were left open during flooring installation work. Monitored boiler operation for thirty minutes, confirmed all components functioning properly, and system returned to normal heating cycle without requiring repairs.
Performed comprehensive furnace tune-up on 20-year-old unit, confirming proper function of all furnace ports through testing. Inspected and verified humidifier operation, which was functioning correctly despite initial concern about clogging. Advised customer that water panel replacement is needed; customer will obtain and install replacement panel independently.
Performed oil furnace tune-up and safety check including fire side cleaning, nozzle replacement, and oil filter replacement on commercial bar line. Diagnostic testing revealed significant negative building pressure when commercial range hood operates, causing combustion air starvation and exhaust backdrafting through multiple pathways. Recommended upgrading to sealed combustion gas boiler to resolve ongoing ventilation issues.
Diagnosed furnace failure caused by detached pulley resulting in stripped motor shaft. Documented damage to 20+ year old unit and completed parts order form for replacement blower motor and pulley. Will return to install new components once parts arrive.
Performed scheduled maintenance on 3-year-old furnace system. Inspected HFR air handler and heat pump, replaced filter, and examined outdoor coil which was found to be clean. Verified thermostat settings through installer options without making changes. System was tested and confirmed to be operating properly with no issues identified.
Replaced failed well pressure tank that was causing water leakage on basement floor. Installed new pressure tank per approved estimate, ensuring proper connection to existing copper piping and pressure gauge assembly. System now operating at correct pressure with no leaks.
Successfully replaced dual pressure switches on the downstairs furnace, ensuring proper system operation. Performed brief inspection of upstairs furnace which appears to be in good working condition. All systems tested and functioning correctly.
Replaced customer's aging pressure tank with new Myers Air Guard model and installed code-compliant upgrades to the plumbing system. Verified proper pressure gauge operation and inspected connections for leaks after installation. Customer advised this is a vacation property requiring advance notice for future service visits.
Responded to no-heat call for 16-year-old furnace. Diagnosed potential pressure switch malfunction causing system failure. Performed system check and temporarily restored operation. Recommended pressure switch replacement and scheduled comprehensive inspection of upstairs furnace unit as preventative maintenance.
Responded to no heat call at residence with LP furnace. Found unit was switched off; restored power and verified operation, though evidence of limit switch activation observed due to heavily clogged filter. Discovered entire house was frozen including plumbing fixtures; thawed frozen condensate trap to restore proper drainage and temporarily disconnected frozen condensate pump. Advised customer to reconnect pump upon return and noted potential for significant plumbing issues once thawing occurs.
Responded to no-heat call for a 4-month-old Lennox heating system. Diagnostic inspection revealed frozen vent pipe causing system failure. Corrective action taken: cut off affected section of vent pipe and verified proper furnace operation, restoring heat to residence.
Responded to no-heat call on 25-year-old Gibson LP furnace. Diagnosed multiple component failures including inoperative blower motor that hummed but wouldn't spin, failing gas valve, and heavily soiled burners. Customer had previously attempted repair by replacing ignitor without success. Comprehensive evaluation conducted with circuit board inspection. Recommended complete system replacement due to advanced age and multiple critical component failures.
Inspected 4-year-old furnace failing to reach high-stage operation despite thermostat being set to 70°F with actual home temperature at 55°F. Determined root cause to be severe airflow restriction due to improper evaporator coil box installation, where the coil was placed inside a pre-existing box causing the SLP furnace to operate at only 70% capacity. Documented installation issue with photos for further consultation with management regarding remediation options.
Completed installation of two toilets with new wax rings, bolt kits, supply lines, and cap sets. Replaced tank-to-bowl gasket on master toilet. Connected drain and supply lines for two lavatory faucets and one laundry faucet, ensuring proper function and no leaks.