We’ve assisted homeowners for over 65 years and will proudly service your home as well.

Whether you need a new furnace in Brighton or to repair a heat pump, we can keep your home at a comfortable temperature during the chilly seasons. Our team will also maintain a furnace or heat pump to keep your repair and utility bills to a minimum for as long as you own them.
How We Can Keep You Warm:
- Heating Repair: The temperatures in your home can drop quickly without a working furnace. Our team will work to fix issues such as a faulty thermostat, faulty electrical panel, and more. We can also work to rule out other problems, such as a gas leak that might damage your home or cause serious health issues.
- Heating Installation: A new furnace means that you won’t have to worry about high maintenance or repair costs. We can install a new unit quickly to minimize the interruption to your life and to return your home to a more comfortable state.
- Heating Maintenance: Maintaining a heating system can save money now and in the long run, as it can help to prevent serious damage that could reduce its lifespan. The Hurlburt Family Rewards Program can make it easier to ensure that you get timely service on an annual basis.
The summer months in our area typically feature long stretches of heat and humidity, with average high daytime temperatures in the mid-80s. Our team of professionals will diagnose and repair a cooling system problem or install a new system to ensure that you’re getting the most for your money.
Let Us Help You Beat the Heat:
>
- Cooling Repair: Our team will diagnose issues such as a broken condenser unit blade, bad capacitor, or whatever else may ail your cooling system. We can also fix damage caused by lightning, ice, or any type of storm.
- Cooling Installation: Installing a new cooling system gives you more control over how each room is cooled by utilizing zoned cooling as well as smart technology. Our team will ensure that the unit is installed properly to avoid unnecessary repairs or other issues.
- Cooling Maintenance: Maintaining your cooling system can prevent you from voiding your warranty or other problems that can cost significant amounts of money. The Hurlburt Family Rewards Program makes it easy and convenient to get the service you need.
- Indoor Air Quality
A burst pipe or clogged drain can lead to water getting into walls, the foundation, or other spaces it shouldn’t. Our team can look for signs and symptoms of faulty plumbing components to ensure that drains, pipes, and the appliances that they supply with water stay in good shape. Water treatment services for the hard water that is prevalent in New Brighton, as well as gas line inspections and repairs, are also available.
Whether you need a wire or outlet repaired or want to turn your home into a smart home, we have you covered. Let our team ensure that the lights stay on and that your home has enough capacity for your computers, appliances, and anything else that uses electricity.
You Can Count on Our Electricians to Help You With These Matters:
- Electrical Repair: A charred outlet or flickering lights could be signs of a defective electrical system. Let us diagnose and fix issues that could cause damage to the circuit breaker or electrical panel or an electrical fire if left unchecked.
- Electrical Installation: Upgrading your home’s electrical panel makes it possible to install a new EV charger or otherwise ensure that the lights won’t go out just because the washing machine is running. Installing new wires may also be a good idea if your current wires are more than 20 years old.
If you need a new furnace installed at your home near Brightwood Hills Golf Course, we’ll be there. If you need a new condenser unit for your home near New Brighton City Hall, we can do
that as well. We’re proud to serve our community and take care to ensure that we treat your plumbing, electrical, or HVAC project as if we were working on our own homes.
Our team is capable of providing quality plumbing, electrical, and HVAC services in a timely and affordable manner. We make it possible to keep your home at a comfortable temperature during the frigid winters and humid summers, and we also are happy to serve as your plumber or electrician when the need arises. We have been in business for more than 65 years, and are ready to serve you for even more!
When you need help from an electrical, plumbing, and HVAC company in New Brighton, give our team at Hurlburt a call today!
Hurlburt Heating & Plumbing has completed 20 jobs in New Brighton, MN between May 2026 and November 2026.
The most recent job was on November 13, 2026.
Hurlburt Heating & Plumbing has completed 27 jobs in New Brighton, MN in the last 12 months. The first job there was in April 2025.
Responded to a no-heat call on a 10+ year old Rheem upright gas furnace and found a heavily clogged air filter restricting airflow. Removed the dirty filter and installed a new one, and the inspection camera showed heavy dust and debris buildup on the interior surfaces, which was contributing to the airflow restriction. System was restored to normal heating operation.
Performed a full inspection of the shower stall and pan to locate the source of a slow leak at the rear wall, using a level to verify pan pitch. Found the pan sloped toward the corner rather than the drain, causing water to pool and accumulate at the wall-to-pan transition, and identified hard water conditions that contribute to staining and buildup. Recommended scheduling a water conditioning specialist to address the water quality.
Performed a complete tune-up and safety inspection on a 22-year-old Lennox furnace, including electrical measurements with a clamp meter and inspection of the condensate drain, which showed rust and corrosion at the drain opening. The heat exchanger shows age-related wear but no cracks at this time; recommend monitoring it closely at future visits and beginning to plan for system replacement given the unit's age.
Performed annual maintenance on the NTI boiler, including cleaning and inspecting the flame ignition system, heat exchanger, and combustion. Checked the gas valve, gas pressure, and pressure switch, cleared debris from the unit, and verified filters and inducer motor amperage. Confirmed water pressure and thermostat operation were normal, and the system, including the indirect-fired water heater and associated piping, was functioning properly with no leaks or damage observed.
Responded to no hot water call affecting entire residence. Upon inspection, found older Richmond Integra tanked water heater not lighting with moisture accumulation inside the unit. Burner assembly failed to ignite and internal water infiltration indicated compromised tank integrity or failed combustion chamber seals. Documented existing installation including copper supply lines, galvanized flue vent configuration, and basement utility room placement. Provided estimate for complete water heater replacement due to age of unit and extent of internal water damage making repair cost-prohibitive.
Completed scheduled annual heating system maintenance as part of membership benefits with no reported issues or symptoms. Performed comprehensive furnace tune-up including inspection of all major components, ductwork connections, and ventilation system. Documented equipment condition with photos showing flexible duct connections to registers and internal metal ductwork components, all found to be in serviceable condition.
Responded to shower handle leak where homeowner had previously attempted repair by replacing stem and cartridge. Upon inspection, identified leak originating between two-piece shower cartridge assembly. Accessed valve through bedroom side of bathroom wall. Disassembled cartridge components, inspected rubber gasket and seals for proper seating, and reassembled valve mechanism. Verified all threading and connections were properly secured on brass cartridge with escutcheon plate.
Performed comprehensive tune-up on 6-year-old residential air conditioning system. Conducted indoor inspection including furnace evaluation, airflow verification, temperature split measurement, air filter assessment, and blower motor speed check. Inspected outdoor unit components including capacitor, contactor, condenser coils, and refrigerant system while evaluating overall cooling efficiency. Cleaned condenser coils and removed debris from around the unit. Refrigerant chart readings were found to be significantly off specification; recommended scheduling follow-up tune-up next season for additional diagnostics and system optimization to ensure proper performance.
Performed inspection of irrigation ball valve shut-off and two exterior hose bibs to assess condition and provide replacement estimates. Upon thorough examination, determined all components were functioning properly with no immediate service needs. Discussed replacement options with homeowner, noting that accessing water supply lines would require drywall removal for proper installation. Homeowner declined to proceed with replacement work at this time. All fixtures left operational and in service.
Responded to emergency call for 100% main sewer line blockage located 58 feet from foundation, confirmed by pre-service camera inspection. Deployed Picote milling machine to clear severe root intrusion obstructing the line. Successfully removed root mass and restored full flow to sewer system. Post-clearing inspection confirmed complete removal of blockage and proper drainage function. Basement area showed evidence of water backup prior to service, which was resolved upon line clearance.
Responded to kitchen sink leak occurring when water drained through the fixture. Upon inspection, identified leak originating from the base of the existing kitchen faucet. Removed and replaced the failed faucet with a new Moen Joplin model 87615BL featuring pulldown spray, Reflex system, and PowerBoost technology in matte black finish. Tested installation for proper operation and verified no leaks present at base or supply connections.
Returned to site for follow-up after capacitor replacement earlier in day due to concerns about unit not cooling below 75°F. Performed comprehensive system inspection including indoor and outdoor units, air filter, airflow, blower and fan motor speed, condensate drain line, and trap. Verified temperature split at 18.5°F between return and supply air. Measured supply air temperatures at main floor and second floor vents, recording readings between 56°F and 60°F. Inspected outdoor unit and confirmed refrigerant readings within normal operating range. Checked coils, incoming voltage, breaker, capacitor, and contactor—all components functioning properly. No fault codes present and system operating normally at time of service. Explained to customer that during extreme outdoor heat conditions (outdoor temperature at 83°F with forecast high of 90°F), system requires extended run time to achieve desired indoor temperature of 68°F, particularly when maintaining large temperature differential on
Responded to no cooling call on residential central air conditioning system. Upon arrival, diagnosed failed capacitor preventing compressor operation. Replaced defective capacitor, restoring system to normal cooling operation and verifying proper function before departure.
Responded to complaint of loud buzzing noise from heat pump system during startup. Diagnosed contactor clattering while energized; verified proper voltage and normal amperage draw on outdoor unit. Refrigerant pressures and supply/return air temperatures measured within acceptable operating range. Discovered air filter installed in incorrect direction and corrected orientation. Recommended contactor replacement to prevent future noise issues, though system currently operating within normal parameters.
Responded to service call for inadequate hot water supply, with customer reporting only 3 minutes of warm water before turning cold during showers and dishwashing. Issue began following previous service visit where technician stood on top of water heater to access corner spigot, raising concerns about potential damage to internal components or thermostat from weight and vibration during pipe cutting work. Inspected indirect water heater system in mechanical room and performed diagnostic testing by running multiple fixtures throughout the residence. Confirmed intermittent hot water delivery with water heating briefly before returning to cold temperature. Conducted thorough inspection of plumbing rough-in to identify potential crossover points between hot and cold water lines, focusing on mixing valves and tub/shower connections as probable failure locations. Tested infrequently used basement shower fixtures and identified significant air pressure imbalance in shower located across fro
Responded to no cooling complaint on residential air conditioning system that had been inoperative for five days following refrigerant line freeze-up. Upon arrival, performed system diagnostic and confirmed unit was low on refrigerant charge. Given the age of the equipment (10+ years) and the condition of the system, recommended full system replacement rather than repair. Customer approved replacement due to age and efficiency considerations. Replaced outdoor condenser unit with new R-410A compatible system. Completed installation, verified proper operation, and confirmed adequate cooling performance before departure.
Replaced a failing water control valve up to 1" on the copper plumbing assembly located in the ceiling access area. The new ball valve with yellow handle was installed to restore proper flow control through the water line. Installation included proper fitting connections to the existing copper piping system, ensuring secure joints and leak-free operation for reliable water shut-off capability.
Completed annual cooling maintenance on a 13-year-old Carrier air conditioning system. Performed comprehensive inspection including contactor, capacitor, condenser coil cleaning, refrigerant charge verification, and amp draw testing. Found fan capacitor showing weak performance and advised customer of potential risk to fan motor if not replaced, but customer elected to monitor at this time. Verified air filter, blower wheel, evaporator coil, control board, and temperature drop all within acceptable specifications.
Completed evaporator coil cleaning service on fan coil unit located in attic space. Coil had significant buildup requiring treatment with Nu-Calgon Evap-Fresh No Rinse coil cleaner and disinfectant to restore proper airflow and system efficiency. System tested and returned to normal operation upon completion.
Performed comprehensive preventive maintenance tune-up on 21-year-old residential air conditioning system utilizing R22 refrigerant. Conducted thorough inspection of all major components including outdoor condenser unit, indoor evaporator coil, electrical connections, and refrigerant lines. Verified proper system operation with amp draw measurements on compressor and fan motor, confirmed adequate airflow through coil surfaces, and inspected condensate drain lines for proper drainage. All components found to be functioning within normal parameters with no deficiencies noted at time of service.