with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Our company provides heating services for furnaces, boilers, and heat pumps. We can also help you protect and enhance your indoor air quality in Mondovi, WI.
Our cooling technicians handle everything from energy-efficient upgrades to precision AC repair in Mondovi, WI. We even have technicians on call for emergency HVAC solutions throughout Mondovi.
We encourage area homeowners to schedule annual plumbing inspections. Our plumbers in Mondovi, WI can identify and correct issues before they get expensive.
We also offer reverse osmosis (RO) systems for households that want cleaner, better-tasting water.
We can help you modernize your home through our electrical services. That includes making it safer and more energy-efficient.
Our team provides cooling and heating repair throughout Mondovi, WI. We provide energy-efficient HVAC solutions that help residents significantly lower their heating bills. Those include high-efficiency furnaces, high-efficiency boilers, and dual-fuel heat pumps. This is an area with many older houses that have electrical systems dating back decades.
Our electricians in Mondovi, WI can upgrade them with new wiring, higher-amp electrical panels, and whole-house surge protection. Our plumbers in Mondovi, WI can help protect your home from the area’s hard water. That can improve water heater efficiency and the lifespan of your major appliances. Poor indoor air quality is a growing health concern, as local winters force people indoors for long periods. We can help you improve your air through air purifiers, humidity control, germicidal lights, and more.
Our family business is proud to serve Mondovi and the surrounding areas. We have over 65 years of experience and have earned more than 6,000 5-star customer reviews. Our team includes certified HVAC technicians, licensed plumbers, and licensed electricians in Mondovi, WI. For installations, we offer free quotes and financing on approved credit. Contact us anytime for emergency HVAC services in Mondovi. We offer same-day appointments and have a live answering service on call 24/7. For maintenance, explore our Hurlburt Family Rewards program. Membership can save you money while making HVAC, plumbing, and electrical maintenance more convenient.
Hurlburt is a local, trusted choice for plumbing, electrical, and HVAC services in Mondovi, WI. We carry that genuine Midwestern hometown care into every house we step into, backed by the skill and equipment to deliver top-tier results. We work with homeowners to help them choose options that will work for them and their households. To schedule an appointment, call today or book online.
Responded to no cooling complaint on recently installed system. Upon arrival, confirmed outdoor unit was not receiving low voltage call from thermostat, though 240V power was present at condenser. Traced control circuit back to indoor furnace and discovered improper wiring at thermostat wire splice point. Previous installer had incorrectly utilized old 2-wire from legacy air conditioner as the connection between thermostat and furnace instead of new thermostat wire. Reconnected wire nut to proper new thermostat wire Y terminal, restoring low voltage control circuit. Verified system operation with multiple power cycles, confirmed 20-degree temperature split across evaporator coil, and ensured all components functioning correctly. System operating as designed.
Responded to no cooling complaint on 2-3 year old Lennox central air system. Upon arrival, confirmed system was blowing warm air with no cooling capacity. Previous service history indicated refrigerant had been added along with UV dye approximately one year prior to identify leak source. Conducted thorough leak inspection of evaporator coil assembly. Observed UV dye splatter present inside ductwork and on evaporator coil panel. Noted thermostatic expansion valve (TXV) exhibited excessive oil accumulation on exterior surface. Applied soap bubble solution to TXV assembly while system was operating under pressure. Successfully isolated active refrigerant leak at TXV body housing. Documented findings with photographs of outdoor condensing unit and evaporator coil components including TXV valve assembly. Explained diagnostic findings to homeowner and demonstrated leak location at evaporator coil. Advised that warranty coverage and parts availability would need verification before procee
Responded to water leak originating from upstairs bathroom and penetrating through ceiling to lower level via exhaust fan opening. Conducted thorough inspection of upstairs bathroom including bathtub-shower combination with tile surround to identify source of water intrusion. Created ceiling access opening in lower level to trace leak path and examine plumbing infrastructure, revealing that water was infiltrating through compromised tile in the upstairs bathroom floor and migrating through structural framing to the level below.
Responded to service call for kitchen sink leak and drainage issues. Upon inspection, identified failed kitchen sink strainer as source of leak beneath sink. Additionally diagnosed backing up drains throughout property caused by mainline sewer blockage, which required coordination with separate sewer service contractor. Replaced defective kitchen sink strainer and continuous waste assembly to resolve leak. Documented existing conditions with photographs showing worn strainer and sink basin prior to replacement. Communicated findings regarding mainline sewer backup to property owner for separate remediation.
Performed comprehensive soot cleaning on oil furnace system due to excessive buildup affecting operation. Removed and thoroughly cleaned heat exchanger, disconnected and cleaned vent pipe from unit to chimney connection, and replaced faulty limit control. All components tested after reassembly with system now operating within normal parameters.
Completed preventative maintenance tune-up on 8-year-old residential air conditioning system with no known issues. Performed comprehensive inspection including drain pan and evaporator coil examination, verified proper system performance with 22°F temperature differential across coil, disassembled and cleaned outdoor condenser unit, tested capacitor and contactor for proper operation, and confirmed overall system functionality. Noted minor vibration from condenser fan motor or blade assembly that homeowner reported as pre-existing condition with no change in operation.
Replaced auto vent cap on boiler after previous installation was incorrect size. Installed new automatic air vent, bled air from system, and tested operation to ensure proper functionality. Measured existing chimney termination cap, which shows significant rust and deterioration around metal collar, for future replacement quote. Additional venting modifications required for proper termination at mechanical room will be quoted separately.
Responded to no cooling call on residential air conditioning system installed less than one year ago. Upon arrival, diagnosed shorted contactor in outdoor condenser unit causing ground fault condition that tripped furnace fuse breaker. Replaced defective contactor under warranty, restored power to system, and verified proper operation of air conditioning unit.
Completed seasonal air conditioning tune-up on 12-year-old GeoComfort geothermal system. Cleaned condensate drain line, tested all components and electrical connections, and verified proper operation of equipment in cooling mode with all systems functioning within normal parameters.
Replaced existing 2-inch reduced pressure zone (RPZ) backflow prevention assembly with new unit, including all necessary fittings and materials. Installation was coordinated during a scheduled water shutdown to minimize service disruption. The new backflow preventer was installed on the potable water system, properly mounted and secured to the wall structure, and integrated with the existing copper and PVC piping configuration. Upon completion, the assembly was tested and certified in accordance with state registration requirements to ensure proper operation and compliance with backflow prevention standards.
Completed comprehensive annual plumbing inspection of residential system, including examination of water pressure tank (operating at 38 PSI) and associated plumbing connections with brass fittings and valving. All plumbing components, electrical monitoring systems, and pressure regulation equipment were inspected and found to be functioning within normal parameters, with documentation captured for service records.
Completed comprehensive plumbing inspection of residential property following standard protocol. Inspection included examination of laundry area plumbing connections, water supply lines to washing machine, and ventilation systems, with photographic documentation of accessible plumbing fixtures and appliance installations for record purposes.
Completed preventive maintenance on two residential air conditioning systems under agreement. Performed comprehensive tune-up on both units including electrical inspection, air filter replacement, condenser coil cleaning, and condensate drain line clearing. Verified proper operation of all equipment with temperature split readings of 20° on the 25-year-old system and 15° on the 7-year-old unit, both within acceptable parameters.
Performed return visit refrigerant leak check on mini split system with reduced efficiency in master bedroom unit. Inspected flare connections at outdoor condenser and indoor heads, discovering significant oil accumulation at condenser flares and active bubbling leak at second floor head unit. Tightened leaking flare connection at indoor head until bubbling ceased and electronic leak detector confirmed seal. Advised homeowner that complete flare connection replacement may be necessary for long-term reliability, though immediate leak was stopped. Provided pricing estimate for comprehensive flare rework on all connections.
Responded to warranty callback for recently installed shower experiencing continuous dripping from overhead faucet. Diagnosed faulty cartridge as source of leak and performed replacement with new cartridge assembly. Tested shower operation to verify proper sealing and confirmed leak was fully resolved.
Responded to service call for furnace shutting off intermittently at night. Performed comprehensive furnace and air conditioning tune-up per maintenance agreement. Upon arrival, conducted furnace inspection and found heavily soiled air filter, which was replaced with customer-supplied unit. Furnace exhibited failure to maintain ignition during initial testing. Inspection revealed severely corroded flame sensor, which was identified as primary cause of shutdown issue. Cleaned and serviced flame sensor to restore proper operation. Performed electrical testing on all furnace components with all readings within manufacturer specifications. Verified condensate drain lines clear and flowing properly. Conducted thorough heat exchanger inspection with no cracks, compromises, or safety concerns identified. Noted significant corrosion on burner assembly, typical of LP gas applications and age of equipment. Burner remains functional but showing wear consistent with propane fuel usage. Complet
Completed comprehensive 12-4 maintenance tune-up on 20-year-old geothermal heat pump system. Performed full equipment inspection including wiping down all accessible components, testing operational functions of major system elements, and flushing the evaporator drain line to ensure proper condensate removal. Verified system operation in heating mode and confirmed radiant in-floor heating functionality, with all components operating within normal parameters.
Completed comprehensive plumbing inspection of residential property as part of friends and family service. All plumbing systems, fixtures, and components were examined and found to be in good working condition. Minor corrosion was observed on several valves in the basement mechanical room, including components near the pressure tank and water distribution system. Documented existing conditions with photographs of mechanical equipment area, including pressure tank, piping connections, water heater, and HVAC components for service records.
Completed friends and family plumbing inspection of residential property. Homeowner reported recurring sewer line freezing issues during the previous two winters. Documented existing plumbing fixtures including toilet and fire suppression sprinkler system, and scheduled follow-up camera inspection of septic line to diagnose freezing concerns.
Performed comprehensive AC tune-up on 33-year-old system including full inspection of indoor and outdoor components. Replaced air filter, verified blower assembly was clean and operating within specifications, confirmed evaporator coil cleanliness and proper condensate drainage, inspected routine outdoor unit components, and cleaned condenser coil. System tested and monitored for 15 minutes with 18-20 degree temperature drop across coil; all components functioning properly despite 40-degree ambient outdoor temperature at time of service.