with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Our company provides heating services for furnaces, boilers, and heat pumps. We can also help you protect and enhance your indoor air quality in Mondovi, WI.
Our cooling technicians handle everything from energy-efficient upgrades to precision AC repair in Mondovi, WI. We even have technicians on call for emergency HVAC solutions throughout Mondovi.
We encourage area homeowners to schedule annual plumbing inspections. Our plumbers in Mondovi, WI can identify and correct issues before they get expensive.
We also offer reverse osmosis (RO) systems for households that want cleaner, better-tasting water.
We can help you modernize your home through our electrical services. That includes making it safer and more energy-efficient.
Our team provides cooling and heating repair throughout Mondovi, WI. We provide energy-efficient HVAC solutions that help residents significantly lower their heating bills. Those include high-efficiency furnaces, high-efficiency boilers, and dual-fuel heat pumps. This is an area with many older houses that have electrical systems dating back decades.
Our electricians in Mondovi, WI can upgrade them with new wiring, higher-amp electrical panels, and whole-house surge protection. Our plumbers in Mondovi, WI can help protect your home from the area’s hard water. That can improve water heater efficiency and the lifespan of your major appliances. Poor indoor air quality is a growing health concern, as local winters force people indoors for long periods. We can help you improve your air through air purifiers, humidity control, germicidal lights, and more.
Our family business is proud to serve Mondovi and the surrounding areas. We have over 65 years of experience and have earned more than 6,000 5-star customer reviews. Our team includes certified HVAC technicians, licensed plumbers, and licensed electricians in Mondovi, WI. For installations, we offer free quotes and financing on approved credit. Contact us anytime for emergency HVAC services in Mondovi. We offer same-day appointments and have a live answering service on call 24/7. For maintenance, explore our Hurlburt Family Rewards program. Membership can save you money while making HVAC, plumbing, and electrical maintenance more convenient.
Hurlburt is a local, trusted choice for plumbing, electrical, and HVAC services in Mondovi, WI. We carry that genuine Midwestern hometown care into every house we step into, backed by the skill and equipment to deliver top-tier results. We work with homeowners to help them choose options that will work for them and their households. To schedule an appointment, call today or book online.
Completed full warranty repair on residential air conditioning system by replacing the evaporator coil and thermostatic expansion valve (TXV). After installation of new components, recharged the system with refrigerant to manufacturer specifications and performed comprehensive operational testing to verify proper cooling performance and system functionality. Unit is operating within normal parameters with no issues detected.
Responded to water leak at RPZ backflow preventer assembly located in parlor near chemical room. Upon inspection, identified active leak at Wilkins backflow prevention device and determined Y strainer requires replacement due to failure. Documented existing conditions showing corrosion on green supply pipe, aged brass valve assembly with compliance tags intact, and multiple ball valves in system. Ordered necessary replacement parts for Y strainer to complete repair and restore proper operation of backflow prevention system.
Responded to service call for geothermal system not cooling properly. Found system had been manually switched from heating to cooling mode but was not functioning correctly. Diagnosed issue with zone control panel wiring configuration at control board. Relocated Y wire from auxiliary terminal to proper Y terminal on control board to restore proper signal to circulating pump, which restored cooling operation. Verified geothermal system now operating correctly in cooling mode with all zones functioning as designed. Recommended installation of three-way switchover valve during scheduled fall heating inspection to eliminate manual switching requirement and prevent future operational issues.
Completed comprehensive AC tune-up on 3-year-old system. Verified all electrical components operating within manufacturer specifications, replaced air filter, and performed thorough cleaning of outdoor condenser unit. System achieved 20-degree temperature differential and is functioning properly.
Responded to no cooling call on 2-3 year old system with outdoor unit not running and warm air at vents. Upon inspection, discovered rodent damage to pressure switch wiring with chewed insulation and exposed conductors. Repaired damaged wire with proper wire nut connection and electrical tape, then sealed all condenser access points with silicone to prevent future rodent intrusion. Tested system operation and confirmed outdoor unit running properly with normal cooling restored.
Responded to no cooling complaint on 20-year-old geothermal system. Upon arrival, discovered the circulation pump supplying cooling to the air handler was unplugged. Restored power to the pump, verified proper operation of the geothermal loop and air handler, and confirmed system was delivering adequate cooling throughout the home. System returned to normal operation.
Responded to no cooling complaint on air conditioning system blowing warm air and experiencing freeze-up. Inspected evaporator coil for blockage and verified clear. Tested system pressures and operation, identifying low refrigerant charge on R-410A system. Presented repair options including worst-case scenario estimate. Per customer authorization, added one pound of R-410A refrigerant with dye tracer to system. Verified proper operation after refrigerant charge. Advised customer this is a temporary repair due to suspected leak and may require future service. Customer declined equipment replacement at this time. Unable to obtain unit specifications due to illegible data tag.
Responded to no cooling complaint on residential central air conditioning system. Upon arrival, confirmed thermostat was calling for cooling and condenser fan motor was operating, but compressor failed to start. Diagnostic inspection revealed severe deterioration of electrical studs on compressor terminal connections, with one stud completely detached from compressor housing. Additionally noted condenser fan motor showing signs of wear with existing hard start capacitor installed and shaft displaying increased resistance during rotation. Documented equipment condition with photographs. Informed customer of failed compressor electrical connections and aging condenser fan motor requiring repair or replacement. Recommended obtaining repair estimates for both components and suggested scheduling system replacement consultation due to advanced age and overall condition of equipment. Customer approved recommendations and replacement consultation was scheduled.
Responded to no cooling complaint on recently installed system. Upon arrival, confirmed outdoor unit was not receiving low voltage call from thermostat, though 240V power was present at condenser. Traced control circuit back to indoor furnace and discovered improper wiring at thermostat wire splice point. Previous installer had incorrectly utilized old 2-wire from legacy air conditioner as the connection between thermostat and furnace instead of new thermostat wire. Reconnected wire nut to proper new thermostat wire Y terminal, restoring low voltage control circuit. Verified system operation with multiple power cycles, confirmed 20-degree temperature split across evaporator coil, and ensured all components functioning correctly. System operating as designed.
Responded to no cooling complaint on 2-3 year old Lennox central air system. Upon arrival, confirmed system was blowing warm air with no cooling capacity. Previous service history indicated refrigerant had been added along with UV dye approximately one year prior to identify leak source. Conducted thorough leak inspection of evaporator coil assembly. Observed UV dye splatter present inside ductwork and on evaporator coil panel. Noted thermostatic expansion valve (TXV) exhibited excessive oil accumulation on exterior surface. Applied soap bubble solution to TXV assembly while system was operating under pressure. Successfully isolated active refrigerant leak at TXV body housing. Documented findings with photographs of outdoor condensing unit and evaporator coil components including TXV valve assembly. Explained diagnostic findings to homeowner and demonstrated leak location at evaporator coil. Advised that warranty coverage and parts availability would need verification before procee
Responded to water leak originating from upstairs bathroom and penetrating through ceiling to lower level via exhaust fan opening. Conducted thorough inspection of upstairs bathroom including bathtub-shower combination with tile surround to identify source of water intrusion. Created ceiling access opening in lower level to trace leak path and examine plumbing infrastructure, revealing that water was infiltrating through compromised tile in the upstairs bathroom floor and migrating through structural framing to the level below.
Responded to service call for kitchen sink leak and drainage issues. Upon inspection, identified failed kitchen sink strainer as source of leak beneath sink. Additionally diagnosed backing up drains throughout property caused by mainline sewer blockage, which required coordination with separate sewer service contractor. Replaced defective kitchen sink strainer and continuous waste assembly to resolve leak. Documented existing conditions with photographs showing worn strainer and sink basin prior to replacement. Communicated findings regarding mainline sewer backup to property owner for separate remediation.
Performed comprehensive soot cleaning on oil furnace system due to excessive buildup affecting operation. Removed and thoroughly cleaned heat exchanger, disconnected and cleaned vent pipe from unit to chimney connection, and replaced faulty limit control. All components tested after reassembly with system now operating within normal parameters.
Completed preventative maintenance tune-up on 8-year-old residential air conditioning system with no known issues. Performed comprehensive inspection including drain pan and evaporator coil examination, verified proper system performance with 22°F temperature differential across coil, disassembled and cleaned outdoor condenser unit, tested capacitor and contactor for proper operation, and confirmed overall system functionality. Noted minor vibration from condenser fan motor or blade assembly that homeowner reported as pre-existing condition with no change in operation.
Replaced auto vent cap on boiler after previous installation was incorrect size. Installed new automatic air vent, bled air from system, and tested operation to ensure proper functionality. Measured existing chimney termination cap, which shows significant rust and deterioration around metal collar, for future replacement quote. Additional venting modifications required for proper termination at mechanical room will be quoted separately.
Responded to no cooling call on residential air conditioning system installed less than one year ago. Upon arrival, diagnosed shorted contactor in outdoor condenser unit causing ground fault condition that tripped furnace fuse breaker. Replaced defective contactor under warranty, restored power to system, and verified proper operation of air conditioning unit.
Completed seasonal air conditioning tune-up on 12-year-old GeoComfort geothermal system. Cleaned condensate drain line, tested all components and electrical connections, and verified proper operation of equipment in cooling mode with all systems functioning within normal parameters.
Replaced existing 2-inch reduced pressure zone (RPZ) backflow prevention assembly with new unit, including all necessary fittings and materials. Installation was coordinated during a scheduled water shutdown to minimize service disruption. The new backflow preventer was installed on the potable water system, properly mounted and secured to the wall structure, and integrated with the existing copper and PVC piping configuration. Upon completion, the assembly was tested and certified in accordance with state registration requirements to ensure proper operation and compliance with backflow prevention standards.
Completed comprehensive annual plumbing inspection of residential system, including examination of water pressure tank (operating at 38 PSI) and associated plumbing connections with brass fittings and valving. All plumbing components, electrical monitoring systems, and pressure regulation equipment were inspected and found to be functioning within normal parameters, with documentation captured for service records.
Completed comprehensive plumbing inspection of residential property following standard protocol. Inspection included examination of laundry area plumbing connections, water supply lines to washing machine, and ventilation systems, with photographic documentation of accessible plumbing fixtures and appliance installations for record purposes.