We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Minnetonka is famous for its cold winters. The Afton Alps and Buck Hill are a blast to ski, and the icy waters of Lake Minnetonka are prime for ice fishing. But to really enjoy those cold-weather activities, you need a cozy place to come home to. Our team can expertly repair, maintain, and install heating systems while helping keep your heating bills down all winter long.
Depend On Us for These Heating and Furnace Solutions:
- Heating repair: A malfunctioning heat exchanger or blower motor causes the heater to use more energy and wear out internal components. From gas valve issues to malfunctioning burner assemblies, we can fix them all.
- Heating installation: We do installations for gas and electric heaters as well as energy-efficient heat pumps to lower your heating costs.
- Heating maintenance: Get your furnace serviced once a year when you sign up for the Hurlburt Family Rewards Program. You’ll save on repairs and accessories and get considerable discounts when it’s time for a heating replacement.
The efficiency of your air conditioning system impacts your ability to relax at home when the weather heats up. We fix issues like refrigerant leaks and blocked air filters so that your home stays cool in the summer. Our installation services help you achieve first-rate air conditioning year-round. When you’re done enjoying water sports at the lake or Minnetonka Mills Park, you don’t have to sweat at home.
We Offer Professional Cooling Services:
- Cooling repair: Stop struggling with weak airflow and inconsistent cooling. Our technicians repair blower motors, frozen evaporator coils, clogged condensate drains, and more.
- Cooling installation: Our installation support is key to selecting the best cooling system for your home. You’ll enjoy cheaper cooling costs and better air quality. We can help you decide if it might make sense to go ductless, too.
- Cooling maintenance: Take advantage of the Hurlburt Family Rewards Program to make your air conditioner last longer and consume less energy. We’ll help you avoid expensive repairs with our yearly tune-up.
See all of our HVAC services in Minnetonka.
Water seepage and pipe corrosion can weaken your home’s framework, causing problems with its foundation. Mold can grow in damp environments caused by leaks. Water bills will skyrocket from even small faucet drips. A plumber from Hurlburt knows how to find and fix these problems. Our hard water in Minnetonka takes a toll on pipes and appliances, so you may want to try our water treatment options as well.
See all of our plumbing services in Minnetonka.
Your electrical system is too important to leave to a company that doesn’t truly care about your safety and comfort. Whether you have a safety hazard or just want complete control over your home illumination with smart lights, we can help. To ensure you have power at all times, even during power outages, we can install a home generator and a surge protector to protect the electronics and appliances you depend on.
Call Our Electricians For:
- Electrical repair: Power surges, flickering lights, and blown fuses are some of the most annoying electrical issues. We can fix all of these problems. Our electricians also specialize in repairing broken outlets, fixing overloaded panels, and replacing aging wiring.
- Electrical installation: Allow us to take care of all electrical installations in your home so it stays safe and up to code. Ceiling fans allow for more efficient heating and cooling. EV charging stations make owning an electric car more convenient than ever.
We serve every neighborhood in Minnetonka. Older homes along Minnetonka Boulevard may have outdated electrical panels and wiring. Or maybe you live in one of the newer homes near Williston Road, and you’re stuck with a leaking faucet. Hurlburt is the team to call whenever you need electrical, plumbing, or HVAC work.
No matter how big or little the job is, we always go above and beyond for our customers. Our dedication to improving the quality of life in Minnetonka drives us to consistently provide an exceptional experience. We are a one-stop shop for all your home service needs, from our family to yours.
Call Hurlburt for the best plumbing, electrical, and HVAC company in Minnetonka!
Hurlburt Heating & Plumbing has completed 20 jobs in Minnetonka, MN between May 2026 and June 2026.
The most recent job was on June 12, 2026.
Completed replacement of single-handle kitchen faucet and installed three new angle stop shut-off valves with supply lines for three toilets throughout the residence. All fixtures were tested for proper operation and verified leak-free connections upon completion.
Responded to emergency call for leaking water softener system in basement utility area. Upon arrival, found water softener experiencing severe leakage from multiple points on the control head assembly, with active water discharge requiring immediate attention. Assessed unit condition and determined repair was not viable due to extent of deterioration and corrosion on copper piping connections. Bypassed the water softener system to restore water flow to the residence and prevent further water damage. Completely removed the failed water softener unit from the plumbing system. Documented existing plumbing infrastructure including copper supply lines, PVC drainage, and water heater connections. Provided detailed estimate for installation of customer-supplied replacement water softener unit.
# HVAC Service Completed Responded to a no cooling call on a 10+ year old system where water leakage was initially reported near the furnace. Upon arrival, confirmed active water leak originating from a failed condensate pump in the mechanical area. System had been shut down with furnace fan left in "on" position to prevent further water damage. Diagnosed the condensate pump as the source of the leak, which had been allowing water to overflow from the drain pan onto the surrounding floor. The failed pump was unable to evacuate condensate water produced during normal air conditioning operation, causing water accumulation and spillage in the utility area. Removed the defective condensate pump and installed a new replacement unit. Reconnected all condensate drain lines and electrical connections to the new pump. Verified proper pump operation and confirmed adequate drainage of condensate water from the system. Tested the air conditioning system through a complete cooling cycle to ensur
Responded to water leak complaint with unknown source affecting residential property. Upon investigation, inspected HVAC furnace system, condensate drainage lines, and plumbing infrastructure in basement utility area. Examined furnace unit with exposed internal components, including blower motor assembly, circuit board, and PVC condensate drain piping with red couplings. Investigated crawlspace area and floor joist cavities, inspecting various water supply lines, drain pipes, and potential leak sources. Observed discoloration and staining on wooden structural members and around plumbing penetrations indicating moisture intrusion. Assessed multiple potential leak sources including AC condensate drainage system, bathtub deck area, and HVAC equipment. Documented conditions with photographic evidence showing furnace components, condensate piping configuration, and crawlspace plumbing infrastructure. Determined leak source exceeded scope of plumbing-only repair and required HVAC specialist
Responded to no cooling complaint on 16-year-old residential air conditioning system. Upon inspection, determined unit was low on obsolete refrigerant. Given the age of the system and the phase-out of the required refrigerant type, discussed repair limitations and replacement options with homeowner. Scheduled estimate appointment for new AC system installation to provide a permanent solution to the cooling issue.
Completed scheduled AC tune-up and preventive maintenance on residential air conditioning system. Performed comprehensive electrical diagnostics using multimeter to verify capacitor function and electrical connections, inspected condenser unit components including capacitor mounting and wire terminals, and replaced air filter per maintenance agreement protocol. All electrical readings confirmed within normal operating parameters, system tested and left in proper working condition.
Responded to service call for frozen shut off valve identified during city water meter replacement. Upon inspection, determined the valve after the meter required replacement due to seized condition. Successfully replaced the defective shut off valve with new brass valve assembly, restoring proper water flow control to the residence. All connections tested and verified operational with no leaks detected.
Replaced two inoperable shut-off valves at the water meter location to prepare for upcoming city meter replacement. The shut-off valve before the meter was experiencing a minor drip and the valve after the meter would not turn properly, rendering both non-functional. Successfully installed new shut-off valves on both sides of the meter to ensure proper water control and system isolation capability.
Performed preventive maintenance agreement tune-up on two residential air conditioning systems. Conducted comprehensive inspection of all electrical components, verified refrigerant charge levels on both units, and pressure-washed condenser coils to remove debris and organic matter. Both systems operating within normal parameters with no deficiencies noted at time of service.
Responded to service call for leaking natural gas water heater with tank failure at bottom of unit. Removed and disposed of failed 50-gallon residential water heater that was actively leaking from compromised tank. Completed full replacement installation of new natural gas water heater, including all necessary plumbing connections, gas line hookup, venting, and electrical controls to restore hot water service to the residence.
Completed annual AC tune-up on 10-year-old system with return visit to finalize maintenance after initial trip encountered ambient temperatures too low for accurate refrigerant testing. Upon return, verified system pressures within normal operating range with 8 degrees subcooling and 21-degree temperature split across evaporator coil. Replaced air filter, performed condenser coil cleaning, and confirmed all components operating properly. Previous visit showed abnormal pressures with low side reading below normal and high side reading above normal, likely due to cold outdoor conditions affecting refrigerant performance. System now functioning correctly with homeowner advised to monitor performance throughout cooling season.
Responded to no cooling complaint on 11-year-old Bryant AC system. Upon inspection, discovered loose thermostat wiring at the furnace connection point that prevented proper communication between the ecobee thermostat and the cooling system. Secured and tightened all thermostat wire connections at the furnace terminal board, restoring proper system operation. Tested system operation through full cooling cycle to verify proper function. Discussed with homeowner the loss of advanced features that occurred when the original Bryant Connex thermostat was replaced with the ecobee unit earlier this year, including compatibility with system-specific controls. Provided information about reinstalling the latest Bryant Connex Wi-Fi thermostat to restore full system functionality and discussed option for adding a separate humidistat for improved humidity control. Office to prepare quotes for both thermostat upgrade and humidistat installation options.
Completed comprehensive tune-up inspection on Lennox furnace and air conditioning system. Performed refrigeration check with measured pressures within manufacturer specifications, verified electrical components and airflow parameters in normal operating range, tested condensate drainage system for proper function, inspected burner assembly and ignition sequence for correct operation, conducted visual heat exchanger inspection with no cracks or deterioration observed, and performed carbon monoxide safety testing with acceptable readings. Evaluated White-Rodgers programmable thermostat functionality and temperature accuracy at 68°F. System demonstrated proper heating and cooling operation with no abnormal noise, vibration, or performance issues detected. Recommended routine seasonal maintenance, regular air filter replacement, maintaining clear outdoor unit clearance, and monitoring for any changes in airflow, temperature output, drainage function, or operational sounds.
Supplied and installed 6 feet of copper waterline connecting to existing pressure vacuum breaker (PVB) and extended new line to existing underground irrigation system. Installed brass valve assembly with dual ball valves for shutoff control, utilizing soldered copper fittings and threaded brass adapters throughout the installation. Mounted plumbing assembly to wooden structural beams in basement area, ensuring proper support and alignment of all piping. Activated water supply to PVB and pressure tested all new fittings and connections to verify system integrity and confirm no leaks were present. All plumbing work completed in accordance with Minnesota Plumbing Code requirements. Installation includes one-year warranty coverage on all labor and parts.
Completed preventive maintenance tune-up on 6-year-old 3-ton air conditioning system under maintenance agreement. Customer reported unit not keeping up during peak summer heat; performed comprehensive system evaluation including refrigerant charge verification, airflow measurements, and component inspection. Confirmed blower fan speed at 1200 CFM and proper refrigerant charge levels. Determined cooling capacity limitations stem from inadequate return air ductwork design in log home construction rather than equipment malfunction. All system components operating within manufacturer specifications; no adjustments made to existing fan speed settings as they are optimized for current ductwork configuration.
Completed seasonal air conditioning tune-up and maintenance on residential cooling system. Upon inspection, refrigerant levels were found to be low, so system was recharged to proper specifications. Customer advised that additional follow-up may be needed during peak temperature conditions to verify system performance under full load.
Completed annual cooling system tune-up on Daikin HVAC unit as part of recurring maintenance agreement. Performed comprehensive inspection, cleaning, and testing of system components with amperage readings confirming proper operation. Unit found to be clean and running within normal parameters with no issues identified.
Responded to service call to replace collector box and gasket on Daikin furnace system under parts warranty. Upon initial return visit, discovered supply house had shipped incorrect collector box; correct part was not available locally. Office coordinated sourcing and shipping of proper replacement part and scheduled follow-up appointment with homeowner for completion of installation.
Responded to gas leak emergency after utility company shut off gas supply to the residence. Conducted thorough inspection of gas piping system throughout the home and identified multiple leaks at various connection points on the gas line, confirming utility company's initial findings. Documented all leak locations with photographs and coordinated comfort advisor appointment to provide comprehensive repair proposal for the gas line repairs needed to restore safe gas service to the home.
Responded to gas leak call on outdoor grill line. Upon inspection, identified crimped and broken gas line at deck floor penetration point. Conducted comprehensive leak check of all gas connections and cleared all other areas. Shut off gas supply to grill for safety. Homeowner requested relocation of gas line in addition to repair. Scheduled comfort advisor appointment to provide quote for complete gas line replacement and relocation to desired position.