We’ve assisted homeowners for over 65 years and will proudly service your home as well.

Minnetonka is famous for its cold winters. The Afton Alps and Buck Hill are a blast to ski, and the icy waters of Lake Minnetonka are prime for ice fishing. But to really enjoy those cold-weather activities, you need a cozy place to come home to. Our team can expertly repair, maintain, and install heating systems while helping keep your heating bills down all winter long.
Depend On Us for These Heating and Furnace Solutions:
- Heating repair: A malfunctioning heat exchanger or blower motor causes the heater to use more energy and wear out internal components. From gas valve issues to malfunctioning burner assemblies, we can fix them all.
- Heating installation: We do installations for gas and electric heaters as well as energy-efficient heat pumps to lower your heating costs.
- Heating maintenance: Get your furnace serviced once a year when you sign up for the Hurlburt Family Rewards Program. You’ll save on repairs and accessories and get considerable discounts when it’s time for a heating replacement.
The efficiency of your air conditioning system impacts your ability to relax at home when the weather heats up. We fix issues like refrigerant leaks and blocked air filters so that your home stays cool in the summer. Our installation services help you achieve first-rate air conditioning year-round. When you’re done enjoying water sports at the lake or Minnetonka Mills Park, you don’t have to sweat at home.
We Offer Professional Cooling Services:
- Cooling repair: Stop struggling with weak airflow and inconsistent cooling. Our technicians repair blower motors, frozen evaporator coils, clogged condensate drains, and more.
- Cooling installation: Our installation support is key to selecting the best cooling system for your home. You’ll enjoy cheaper cooling costs and better air quality. We can help you decide if it might make sense to go ductless, too.
- Cooling maintenance: Take advantage of the Hurlburt Family Rewards Program to make your air conditioner last longer and consume less energy. We’ll help you avoid expensive repairs with our yearly tune-up.
See all of our HVAC services in Minnetonka.
Water seepage and pipe corrosion can weaken your home’s framework, causing problems with its foundation. Mold can grow in damp environments caused by leaks. Water bills will skyrocket from even small faucet drips. A plumber from Hurlburt knows how to find and fix these problems. Our hard water in Minnetonka takes a toll on pipes and appliances, so you may want to try our water treatment options as well.
See all of our plumbing services in Minnetonka.
Your electrical system is too important to leave to a company that doesn’t truly care about your safety and comfort. Whether you have a safety hazard or just want complete control over your home illumination with smart lights, we can help. To ensure you have power at all times, even during power outages, we can install a home generator and a surge protector to protect the electronics and appliances you depend on.
Call Our Electricians For:
- Electrical repair: Power surges, flickering lights, and blown fuses are some of the most annoying electrical issues. We can fix all of these problems. Our electricians also specialize in repairing broken outlets, fixing overloaded panels, and replacing aging wiring.
- Electrical installation: Allow us to take care of all electrical installations in your home so it stays safe and up to code. Ceiling fans allow for more efficient heating and cooling. EV charging stations make owning an electric car more convenient than ever.
We serve every neighborhood in Minnetonka. Older homes along Minnetonka Boulevard may have outdated electrical panels and wiring. Or maybe you live in one of the newer homes near Williston Road, and you’re stuck with a leaking faucet. Hurlburt is the team to call whenever you need electrical, plumbing, or HVAC work.
No matter how big or little the job is, we always go above and beyond for our customers. Our dedication to improving the quality of life in Minnetonka drives us to consistently provide an exceptional experience. We are a one-stop shop for all your home service needs, from our family to yours.
Call Hurlburt for the best plumbing, electrical, and HVAC company in Minnetonka!
Hurlburt Heating & Plumbing has completed 20 jobs in Minnetonka, MN between August 2026 and September 2026.
The most recent job was on September 30, 2026.
Completed comprehensive preventative maintenance tune-up on both air conditioning and furnace systems. During inspection, discovered critical heat exchanger failure with visible cracks and evidence of rodent intrusion in the outdoor AC unit causing component damage. Due to the age of the equipment and severity of the damage, recommended full system replacement for safety and efficiency.
Completed annual heating maintenance visit on a 7-year-old furnace system under maintenance agreement. Performed comprehensive inspection including thermostat verification, air filter assessment, drain line check, and electrical component evaluation of blower motor, inducer motor, capacitor, and wiring connections. Verified proper temperature split across system and conducted detailed safety inspection of heat exchanger, igniter, flame sensor, and gas pressure readings. All components found to be operating within normal parameters with no deficiencies noted. System is functioning properly at time of service completion.
Completed annual preventative maintenance heating visit on two gas furnaces, one located in the garage and one in the home. Performed comprehensive tune-up procedures including inspection of one humidifier, gas heater, and gas fireplace. Replaced air filters and inspected flexible ductwork in attic space, noting normal condensation patterns on metallic surfaces. All equipment operating within normal parameters with no issues identified during inspection.
Installed customer-supplied Toto bidet washlet seat on existing toilet fixture. Connected water supply line to washlet unit and verified all connections were secure with no leaks detected after multiple flush cycles. Unable to perform full operational testing of electronic bidet functions due to lack of electrical power supply at time of installation. Washlet seat is properly mounted and plumbed, ready for use once electrical connection is established by customer. One-year parts and labor warranty provided for installation work performed; no warranty coverage applies to customer-supplied washlet unit itself.
Performed comprehensive furnace tune-up and maintenance inspection. Verified electrical connections at circuit breaker panel, tested capacitor reading at 10.9 mFD using digital meter, and inspected all HVAC wiring and components. All systems operating within normal parameters with no deficiencies noted.
Completed comprehensive maintenance on 5-year-old Daikin furnace system. Performed full system inspection verifying ignition and flame safety operation, burner condition, heat exchanger integrity, gas valve function, and electrical amp draws—all within normal parameters. Blower wheel found clean with proper operation. Replaced air filter and performed humidifier maintenance including cleaning pad housing and installing new humidifier pad. Conducted combustion analysis confirming proper efficiency and verified temperature rise within manufacturer specifications. All system components operating correctly with no deficiencies noted.
Completed routine HVAC maintenance on a 2-year-old furnace system. Identified and addressed dirty air filter and flame sensor during inspection. Replaced air filter and thoroughly cleaned flame sensor to restore optimal system performance. System tested and verified to be operating properly upon completion.
Completed preventive maintenance on high efficiency boiler with in-floor heating system and air exchanger unit. Cleaned and scrubbed flame sensor, verified system pressure at 16 PSI within acceptable range, and tested both heating zones for proper operation with satisfactory warm-up. Conducted carbon monoxide safety test measuring 14 PPM, confirming safe operational levels. Inspected air exchanger filter and found in good condition. Cleaned exterior ventilation to ensure proper airflow to air exchanger. All systems tested and verified ready for winter operation.
Completed comprehensive annual maintenance agreement covering both heating and cooling systems. Performed spring tune-up on one air conditioning unit and one air exchanger, along with fall tune-up on one furnace, one in-floor radiant heating system, and one GFP unit. During inspection, diagnosed failing ECM condenser fan motor on the air conditioning unit and successfully replaced the defective motor to restore proper system operation. All ductwork and system components were inspected and photographed, showing flexible metallic ductwork with typical wear patterns and insulation in satisfactory condition. Systems tested and confirmed operational upon completion.
Completed pre-paid maintenance visit at commercial property for recurring plumbing inspection service. Performed comprehensive inspection and descaling of 8-year-old tankless water heater unit. Flushed system according to manufacturer specifications to remove mineral buildup and ensure optimal performance. Inspected mechanical room plumbing infrastructure including water softener system, supply lines, and associated valving. Inspected toilet tank components and noted mineral deposits consistent with hard water conditions. All systems operational upon completion. Customer requested advance notification upon arrival, which was provided.
Completed annual cooling and heating maintenance visit on one AC unit and one furnace. Performed comprehensive tune-up on both systems, replaced dirty air filter, and documented equipment condition with photos of ductwork and surrounding mechanical systems.
Completed installation of SL280V 80% AFUE, 2-stage, variable speed upflow furnace rated at 70,000 BTU in basement utility area. Installation included adapting existing venting and gas lines, installing return air drop, reusing existing thermostat, and installing 16x25x1 filter. Disconnect switch required reinstallation to meet code requirements; reinstalled disconnect switch, energized system, and verified proper operation. All components tested and confirmed operational, including humidifier integration and electrical connections at main panel.
Responded to no cooling complaint on Trane rooftop unit less than 10 years old. Found thermostat calling for cooling with air handler blower operating, but compressor failing to start while condenser fan ran normally. Diagnosed failed run capacitor with multimeter showing open circuit. Replaced defective capacitor, cycled system to verify compressor operation, and confirmed normal refrigerant levels and airflow. System restored to normal cooling operation.
Responded to no cooling complaint on 7-year-old Daikin air conditioning system as follow-up to initial diagnostic visit. Verified proper refrigerant charge and conducted comprehensive system evaluation. Discovered evaporator coil experiencing partial cooling with only bottom third achieving proper temperature while remainder stayed warm. Performed hot and cold test on thermostatic expansion valve (TXV) which confirmed valve operating correctly, eliminating TXV failure as root cause. Diagnostic findings indicate plugged capillary tubes at TXV outlet preventing proper refrigerant distribution through evaporator coil. Documented system conditions with photographs of control board wiring and coil temperature readings showing 63°F on affected section. Submitted parts request for evaporator coil replacement estimate and coordinated service advisor appointment for customer to review repair versus system replacement options.
Responded to no cooling complaint on 7-year-old Daikin system. Upon arrival, discovered outdoor condenser coil heavily impacted with dirt and debris, and capacitor had failed. Verified indoor air filter was clean, blower motor operating correctly, and airflow adequate through supply registers. Replaced failed capacitor and performed thorough condenser coil cleaning to restore proper heat transfer capability. After completing repairs and restarting system, monitored operating pressures and temperatures. While system pressures showed improvement from initial readings, high-side pressure remained elevated and suction line temperature indicated insufficient cooling. Conducted comprehensive TXV bulb response testing using both warm and cold water applications while monitoring suction pressure, superheat, and subcooling values. Testing revealed no meaningful changes in system parameters, indicating TXV is not responding to temperature variations as designed. System currently runs but fail
Performed furnace tune-up and safety inspection on a 19-year-old unit. Heat exchanger inspection revealed no visible cracks but identified stress points showing signs of potential future failure. CO readings in the flue measured elevated at 220-240 ppm during high fire operation, while gas pressure remained within acceptable range. These findings indicate likely heat exchanger deterioration not visible during inspection. Scheduled furnace replacement estimate for same day due to safety concerns and age of equipment.
Responded to service call for water softener with standing water and salt not dissolving properly. Upon arrival, tested water hardness which measured 25 grains per gallon, confirming unit was not regenerating effectively. Diagnosed blocked drain line preventing proper system cycling. Cleared obstruction from drain line, restoring proper water flow and drainage. Verified system operation and regeneration cycle functioning correctly after repair.
Responded to no cooling complaint on 14-year-old residential air conditioning system. Upon diagnostic evaluation, discovered failed dual-run capacitor reading 26 mfd/0 mfd against rated specification of 45/5 mfd, explaining customer's previous need to manually start condenser fan motor. Replaced defective capacitor with new unit matching OEM specifications. Inspected air filtration system and found heavily soiled pleated filter restricting airflow; installed new replacement filter. Verified condenser operation with system startup, confirmed proper compressor and fan motor function. Checked refrigerant pressures and temperatures, all readings within normal operating parameters. System restored to full cooling capacity with no additional issues identified.
Responded to water leak service call at residential property. Installed customer-provided factory braided supply hose at kitchen sink faucet. Contacted customer en route to confirm arrival time, then returned to complete installation. Verified proper connection and tested for leaks to ensure system integrity.
Responded to service call for leaking outdoor hose bib and non-functional laundry valves. Upon inspection, determined the exterior hose bib required full replacement due to leak and the laundry room shut-off valves were seized and inoperable from corrosion. Successfully replaced the outdoor hose bib with new fixture and replaced both corroded laundry valves to restore proper water control functionality.