Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in September 2026.
The most recent job was on September 21, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Completed follow-up phone call to address customer inquiry regarding humidifier operation following earlier service visit. Provided technical guidance on optimal humidifier settings and explained proper temperature-related adjustments for the system. Customer questions resolved satisfactorily.
Responded to emergency call for leaking water heater. Upon arrival, found water actively leaking from the bottom of the existing 40-gallon power vent water heater tank, indicating internal tank failure requiring immediate replacement. Water supply to the unit was shut off to prevent further water damage. Removed the failed 40-gallon power vent water heater from the installation location. Installed new Bradford White 40-gallon power vent water heater as replacement unit. Connected new water heater to existing copper water supply lines with appropriate fittings and shut-off valves. Made gas line connection to burner assembly using existing gas supply piping. Connected power vent exhaust system to existing ventilation ductwork to ensure proper combustion gas venting. Restored water supply and gas supply to the new unit. Performed complete system startup and operational testing. Checked all water connections for leaks under pressure. Verified proper gas combustion and burner operation. C
Responded to basement bathroom plumbing issues involving a continuously running toilet and dripping sink faucet. Diagnosed faulty fill valve assembly with leaking float rod mechanism causing water to overflow from tank top. Removed existing fill valve and installed new replacement unit to restore proper water level control and eliminate running water condition. Sink faucet drip also addressed during service call.
Completed comprehensive furnace safety inspection and certification for residential property. Performed thorough examination of heating system components, ductwork, and insulation in mechanical space. Documented all findings with photographic evidence, prepared certification letter per requirements, and submitted documentation directly to property owner as requested for municipal filing purposes.
Responded to service call for non-functional Carrier air conditioning system. Diagnosed failed compressor on outdoor condenser unit. Removed defective compressor and installed new replacement unit. Properly recovered refrigerant using recovery equipment, replaced compressor assembly, evacuated system, and recharged to manufacturer specifications. Tested system operation and verified proper cooling performance upon completion.
Performed comprehensive maintenance inspection on six-year-old Carrier furnace. Verified ignition and flame safety systems operating properly, confirmed gas valve functionality, inspected burners and found in good condition, and measured amp draws within specifications. Cleaned flame sensor, replaced air filter, confirmed blower wheel cleanliness, inspected heat exchanger with no issues detected, performed combustion analysis with satisfactory results, and verified temperature rise within manufacturer specifications. All systems functioning properly with no deficiencies identified or recommendations needed at this time.
Responded to service call for toilet repair in upstairs bathroom where closet bolts had broken during previous maintenance attempt. Performed complete toilet pull and reset procedure, replacing failed closet bolts with new hardware to secure fixture properly to flange. Assessed upstairs bathroom sink faucet leak that occurred after attempted replacement by occupant; identified potential need for new shut-off valves to complete faucet installation correctly. Toilet successfully reinstalled and secured with new mounting bolts, restoring proper function and stability to fixture.
Completed annual maintenance tune-up on boiler and heat pump system. Performed comprehensive inspection of boiler including assessment of cleanliness, efficiency, and combustion safety. Adjusted boiler water pressure from low reading to optimal level of 15 psi. Verified clean burners, safe combustion process, and proper operation of all electrical components. Inspected piping system with no leaks or rust detected. Evaluated heat pump performance and confirmed effective heating operation. Inspected air filter found to be clean and verified all electrical components in good working condition. Both systems tested and confirmed ready for winter operation with no outstanding issues identified.
Completed scheduled maintenance agreement heating visit on a 2-year-old residential HVAC system consisting of one furnace and one humidifier. Performed comprehensive inspection of thermostat operation, air filter condition, condensate drain, blower motor, inducer motor, capacitor, and all electrical wiring connections—all components found in satisfactory condition. Evaluated temperature split across the system and confirmed proper performance parameters. Conducted thorough examination of furnace heat exchanger for cracks or deterioration, tested igniter and flame sensor functionality, and measured gas pressure at manifold. Adjusted gas pressure to manufacturer specifications to ensure optimal combustion efficiency and safe operation. Inspected humidifier operation, verified water panel condition, and confirmed proper drainage function. Homeowner supplied replacement water panel for installation during service visit. All systems tested and verified to be operating within normal paramete
Responded to no-heat call on residential furnace system following previous maintenance service. Upon arrival, found thermostat indicating system operation but no heat output from unit. Performed diagnostic inspection and discovered gas supply valve on furnace branch line in closed position, likely inadvertently left off after last tune-up service. Opened gas valve to restore fuel supply to unit. Verified furnace ignition sequence, confirmed burner operation, and tested system through complete heating cycle. Unit now fully operational with proper heat output.
Completed comprehensive furnace tune-up and maintenance on a 12-year-old heating system. Performed full system inspection including thermostat verification, indoor air handler assessment, and evaluation of all critical components. Checked air filter condition, condensate drain operation, blower motor performance, inducer motor function, capacitor integrity, and electrical wiring connections—all found to be in satisfactory condition. Verified proper temperature split across the system. Conducted thorough examination of furnace heat exchanger for cracks or deterioration, tested igniter operation, inspected flame sensor for proper function, and measured gas pressure to ensure proper fuel delivery—all components operating within manufacturer specifications. System is functioning normally with no deficiencies noted at time of service completion. Homeowner enrolled in preventative maintenance membership program for ongoing system care.
Responded to emergency main line break with active water leak at the meter assembly. Upon arrival, confirmed leak was originating from the connecting valve attached to the water meter. Immediately shut off water supply to the residence to prevent further water damage and flooding. Customer had already procured a new meter horn for replacement. Removed the failed connecting valve from the existing meter assembly. Installed the new meter horn with proper connections to ensure secure, leak-free operation. Verified all pipe connections were properly seated and tightened to manufacturer specifications. Restored water service to the property and performed pressure testing to confirm the repair eliminated the leak. Inspected surrounding plumbing infrastructure including copper supply lines and shutoff valves for any additional concerns. Left the meter assembly fully operational with no active leaks detected. Cleaned work area and ensured all debris from the repair was removed from the premi
Performed scheduled maintenance inspection on 5-month-old boiler system and associated hydronic heating manifold. All equipment found to be operational with proper zone valve function, manifold controls responding correctly, and copper piping connections secure throughout the multi-zone heating system.
Responded to a service call for a leaking exterior hose bib. Upon inspection, verified that the shut-off valve controlling water flow to the frost-free hose bib was functioning properly. Diagnosed the issue as a stem leak that occurred whenever the hose bib was turned on. Removed the defective hose bib and installed a new frost-free hose bib in its place. Completed all necessary water line connections and tested the fixture for proper operation. Confirmed no leaks and verified full functionality of the replacement hose bib.
Responded to service call for musty odor complaint in mini-split system following previous maintenance visit. Verified both indoor units were operating correctly with proper cooling and drainage function. Inspected first unit reporting musty smell and found no visible mold or buildup, though discussed potential evaporator coil cleaning to address odor concern. Inspected second unit and discovered mold growth on blower wheel, interior panels, and grill assembly. Provided estimate for deep cleaning of both indoor mini-split heads, which was declined at this time, and forwarded written estimate for future consideration.
Completed routine maintenance tune-up on a 4-year-old Goodman HVAC system in preparation for the winter season. Performed comprehensive inspection of all internal components including blower motors, electrical connections, and safety controls; all components found to be in proper working order with no issues identified. Inspected flexible ductwork in attic space and documented conditions for customer records.
Conducted follow-up call to address customer concerns regarding initial estimate and fixture options. Discussed alternative fixture selections that would maintain proximity to existing configurations while meeting budget expectations. Documented garage ceiling infrastructure including exposed joists, garage door opener assembly, and electrical components to support revised estimate preparation.
Completed routine maintenance on 8-year-old boiler as part of heating system maintenance agreement. Performed comprehensive tune-up including testing all components, verifying water temperature and pressure, checking gas pressure, and measuring carbon monoxide levels in flue—all testing within acceptable specifications. However, detected carbon monoxide spillage of 4-6 ppm leaking from bottom right side of heat exchanger, which while below the maximum allowable spillage threshold of 9 ppm, indicates compromised heat exchanger integrity. Boiler remains operational but recommend boiler replacement due to CO leakage, as any carbon monoxide escaping outside the sealed combustion chamber represents a safety concern and system degradation.
Responded to service call for reported toilet leak in residential bathroom. Upon inspection, identified water marks on flooring near toilet base consistent with leak at wax ring seal. Performed new homeowner inspection and assessed toilet condition and installation. Provided professional estimates for toilet replacement and lavatory faucet replacement options as requested by homeowner for future consideration.
Completed scheduled heating system maintenance on two Goodman units as part of membership agreement. First unit showed signs of failing hot surface igniter and inducer motor; provided repair quote for these components. Second unit operating normally with no issues found during tune-up inspection.