Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN between September 2026 and October 2026.
The most recent job was on October 2, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Completed full HVAC system upgrade by removing existing 80% efficiency furnace and installing new EL297V 97% AFUE two-stage variable speed upflow furnace rated at 70,000 BTU. Added complete air conditioning system including EL15KC1 15.9 SEER2 single-stage 2.5 ton outdoor condenser unit and 3-ton B-frame cased evaporator coil with factory-installed TXV valve. Upgraded to high-efficiency 90% furnace requiring new PVC venting installation to meet condensing furnace requirements. Coordinated with electrician for installation of new dedicated electrical circuit to support upgraded equipment. Installed new outdoor concrete pad, disconnect box, and electrical whip for condenser unit. Mounted outdoor unit on pad against building exterior with proper refrigerant line connections using insulated line set. Performed system commissioning including pressure testing with dual-port manometer to verify proper refrigerant charge and airflow. All equipment installed per manufacturer specifications and l
Responded to service call for reported gas leak originating from countertop insert. Upon arrival, gas supply had already been shut off by utility company. After assessment, informed customer that gas line repairs and leak detection fall outside our scope of HVAC services and recommended contacting a licensed gas plumber for proper diagnosis and repair of the 20-year-old gas lines.
Performed comprehensive inspection on 10-year-old NTI high-efficiency boiler for home sale purposes. Verified water pressure and temperature within specifications, confirmed expansion tank operational, tested combustion blower and Venturi assembly functioning properly, measured gas pressure at correct levels, and conducted flue gas analysis confirming safe CO levels. All system components tested within manufacturer specifications; unit determined safe and fully operational.
Responded to service call for approximately one-year-old Rheem hybrid heat pump water heater displaying compressor low airflow warning messages. Upon inspection, diagnosed evaporator coil icing condition despite recent filter replacement. Documented error codes and unit condition with photographs. Contacted manufacturer technical support to verify diagnosis and arrange warranty replacement part for evaporator coil assembly. Unit is covered under manufacturer warranty for parts replacement.
Performed comprehensive seasonal maintenance and tune-up on 15-year-old central boiler system with radiator distribution. Inspected circulator pumps, piping connections, shut-off valves, and all mechanical components for proper operation and winter readiness. System evaluated and prepared for heating season demand.
Completed scheduled furnace tune-up and maintenance under recurring heating service agreement. Replaced dirty air filter and performed standard system inspection. Documented existing conditions including accumulated debris near ductwork connections and assessed sensor/switch wiring components during routine maintenance procedures.
Completed comprehensive tune-up on 3-year-old NTI high-efficiency boiler system. Verified CO levels safe in flue, confirmed proper gas pressure, and inspected combustion blower and Venturi assembly. Checked water pressure and temperature readings for proper operation, confirmed expansion tank functioning correctly, and verified all zone motors opening and closing as designed. Cleared condensate trap and drain line, cleaned ignitor and flame rod to ensure reliable ignition. All system components tested and confirmed fully operational with no deficiencies noted.
Completed comprehensive furnace tune-up on 10-year-old unit. Performed full system diagnostics including electrical measurements, gas pressure testing, and combustion analysis. All components tested within manufacturer specifications with safe CO levels confirmed in the flue. Heat exchanger inspection revealed minor temperature stress but no cracks or secondary leakage detected. System confirmed fully operational. Evaluated existing air cleaner and provided information regarding whole home HEPA filter upgrade options.
Performed comprehensive maintenance on an 11-year-old furnace system. Conducted thorough inspection of thermostat, air filter, drain system, blower motor, inducer motor, capacitor, and all electrical wiring connections—all components found to be functioning properly. Verified temperature split across system and confirmed proper operation of heat exchanger, igniter, flame sensor, and gas pressure levels. Identified that the system had tripped on the high limit switch. Determined that a dirty air filter was the likely contributing factor causing restricted airflow and triggering the safety limit. Recommended implementing a quarterly filter replacement schedule to prevent future occurrences. Attempted to access the pressure adjustment test port to fine-tune gas pressure settings as an additional preventive measure, but the port could not be removed at this time. Following the inspection and addressing the identified issue, the system was returned to normal operating condition. Advised m
Responded to reported water leak concern at hot water heater with crystallized buildup on PVC vent pipe. Conducted thorough inspection of 2-inch PVC vent connection and found joint secure with no active leak present. Determined crusty buildup posed no safety concern and did not require immediate repair. Completed full system inspection and documented findings with photographs. Resolved customer rewards membership issue and provided reassurance regarding equipment condition.
Completed annual boiler maintenance at rental property, performing ambient temperature readings on exterior of boiler unit and inspecting mechanical thermostat for proper operation. Cleaned heat exchanger surfaces and resealed connections to ensure efficient operation and prevent potential leaks. System checked and left in proper working condition.
Completed annual heating maintenance visit on two approximately 1-year-old HVAC systems as part of maintenance agreement. Performed comprehensive inspection of both heat pumps, verifying operation and temperature splits within normal parameters. Conducted thorough furnace evaluations including thermostat operation, filter condition, drain lines, blower motors, inducer motors, and electrical wiring. Inspected heat exchangers, igniters, flame sensors, and measured gas pressure on both units. Gas pressure on both furnaces was slightly elevated and adjusted to manufacturer specifications. Verified proper operation of humidifiers on both systems, inspecting water panels and drain lines. Performed fireplace maintenance including cleaning and inspection of pilot assembly, glass, logs, embers, wiring, and gas valve. All systems tested and confirmed operating normally following service completion.
Replaced defective burner assembly on a 2-year-old furnace unit under parts and labor warranty coverage. Removed front access panel, disconnected gas line and electrical connections, and installed new burner assembly. Conducted thorough safety inspection including gas leak test at all connections and verified proper ignition sequence and burner operation before restoring unit to service.
Responded to callback for insufficient hot water issue following previous service visit. Upon arrival, confirmed water temperature only reaching lukewarm throughout residence with shower running cold. Inspected shower valve temperature adjustment mechanism and water heater thermostat settings, finding both set to low positions. Adjusted shower mixing valve temperature limiter and increased water heater thermostat settings to restore proper hot water delivery to fixtures.
Performed comprehensive maintenance on a 40-year-old furnace system. Inspected and verified proper operation of Honeywell thermostat, blower motor, electrical wiring, and homeowner-supplied filter. Conducted thorough examination of heat exchanger, igniter, and flame sensor with all components functioning within normal parameters. Measured gas pressure and found it slightly elevated above manufacturer specifications; adjusted gas valve to bring pressure to proper operating range. Verified temperature split across system and confirmed adequate heating performance. All safety controls tested and operating correctly. System is functioning normally at this time.
Responded to kitchen faucet sprayer malfunction where the decorative escutcheon and mounting components had separated from the base unit, leaving no adequate surface for secure attachment. Upon inspection, determined that the sprayer assembly lacked proper structural support for permanent repair. Disconnected the compromised faucet components and provided temporary support to the sprayer parts. Documented the existing bridge-style faucet configuration with chrome finish and completed parts sourcing form to facilitate replacement of the damaged sprayer assembly and mounting hardware.
Completed comprehensive hose bib replacement and plumbing upgrades including installation of frost-free 3/4" hose bib on front of house and replacement of threaded 3/4" hose bib on rear of house. Added stop and drain valves on piping in ceiling for improved water control and winterization capabilities. Installed Precision Plumbing Products pressure balancing valve (ASSE 1016 compliant) on two-handle tub/shower valve system accessed through wall cavity behind shower fixture. During service, discovered main water valve was inoperative and required alternative water control methods to complete installations. All copper supply lines were properly connected using push-fit brass fittings to new valve assemblies. Work performed in basement ceiling area with notation that installed components will require relocation when basement ceiling finishing occurs in future. Submitted parts requisition form for required materials and documented main valve failure for future repair scheduling.
Responded to mainline backup caused by extensive tree root intrusion throughout the main sewer line. Utilized flex shaft machine to cable and remove tree roots from the line, running water simultaneously to flush debris during the cabling process. Encountered extremely thick root mass at approximately 10 feet that could not be fully ground down, though multiple root masses were successfully cleared to restore flow. Performed video camera inspection of the sewer line upon completion to verify the line was open and flowing properly. Due to the severity of tree root infiltration and remaining root masses, recommended sewer liner installation to prevent future root intrusion and pipe deterioration.
Completed preventive maintenance tune-up on two furnaces and one condensing boiler, all approximately seven years old. Addressed LOC 5 lockout code on condensing boiler by tracing wiring to purple and yellow wire connections, reseated loose wire connections, and successfully restored boiler operation with proper heating function. All equipment inspected and operating within normal parameters.
Completed annual heating maintenance visit on one NTI boiler and one gas fireplace. Performed comprehensive inspection of boiler system including ignition and flame safety verification, heat exchanger examination, burner assessment, and gas valve operation check. Inspected all system piping, circulators, and zone valves for proper operation and leaks. Conducted combustion analysis with readings within acceptable parameters. All system components are functioning as designed with no deficiencies noted at this time.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.