Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in July 2026.
The most recent job was on July 16, 2026.
Hurlburt Heating & Plumbing has completed 1,700 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Responded to no cooling callback on 2-3 month old AC system that had shut down with fan error code after outdoor unit became blocked with cottonwood debris. Upon arrival, system was operational as homeowner had already cleaned exterior coil approximately 45-50 minutes prior, clearing the obstruction and restoring normal function. Verified system performance with delta-T reading of 21°F across evaporator coil, confirming adequate cooling capacity. Inspected outdoor coil condition and noted satisfactory cleaning by homeowner. Observed air filter requiring replacement, which homeowner will complete same day. No error codes present at time of inspection and all system functions operating within normal parameters.
Completed annual spring cooling system tune-up and preventive maintenance on single standard air conditioning unit as part of recurring maintenance agreement. Performed comprehensive inspection of Bryant Plus 95s Evolution furnace system, verified electrical connections at breaker panel, checked refrigerant levels, cleaned condenser coils, tested thermostat operation, and confirmed all safety controls functioning properly. System operating within manufacturer specifications with no deficiencies noted.
Responded to no cooling complaint with warm air from vents. Inspected recently customer-installed thermostat wiring at wall and verified connections at furnace control board. Confirmed thermostat call signal present. Proceeded to outdoor unit and found condenser operating. Performed comprehensive diagnostic including voltage checks, refrigerant pressures and temperatures, capacitor testing, and low voltage circuit verification. Measured 17-degree temperature split at supply registers, confirming system operating within normal parameters at time of inspection. Unable to identify definitive cause of intermittent cooling issue reported by occupants. Potential causes include malfunctioning energy saver switch or defective thermostat despite recent replacement. Verified proper thermostat wiring configuration at Nest base plate with appropriate Y, G, RC, and W terminal connections. Instructed homeowner on proper use of HOLD function to prevent schedule overrides affecting set temperature. I
Completed comprehensive AC maintenance on a single 5-year-old residential cooling system with R-410A refrigerant under ambient conditions of 90°F. Performed thorough inspection and testing of all critical components including air filter, Honeywell thermostat, temperature split across evaporator coil, outdoor condenser unit, condenser and evaporator coils, blower motor, capacitors, compressor operation, refrigerant charge levels, and condensate drain system. All components tested within normal operating parameters with no deficiencies identified. System cooling efficiently with proper airflow and refrigerant charge confirmed.
Responded to service call for 4-year-old Rheem Classic Pro gas water heater with visible leaking from drain pan. Upon inspection, found compromised drain pan with rusted floor drain hose and deteriorated water retention capacity. Drain pan was also receiving condensate discharge from HVAC system, contributing to overflow condition. Relocated water heater unit and installed new drain pan with proper drainage connections to accommodate both water heater discharge and HVAC condensate lines, restoring proper containment and drainage functionality.
Responded to callback regarding loose faucet handles on dual-sink vanity installation from previous week. Removed and retightened chrome faucet handles, confirming that slight movement is inherent to the handle design and within manufacturer specifications. Replaced missing screw in shower floor drain assembly that was inadvertently left out during prior service visit.
Responded to a no-cooling complaint on a 15-year-old central air conditioning system at a duplex unit. Upon arrival, found the thermostat set to heat mode; when switched to cooling, the system failed to activate. Removed thermostat from wall plate and discovered a bent terminal prong preventing proper electrical contact. Straightened the bent prong, verified battery installation, and reinstalled thermostat to wall plate. Cycled system through heating and cooling modes to confirm proper operation. System restored to full cooling functionality with no additional repairs required.
# HVAC Maintenance Completed Performed annual cooling system maintenance on a 6-year-old Unico air conditioning unit as part of a recurring preventive maintenance agreement. Conducted comprehensive tune-up including inspection of blower motor assembly, electrical connections, and evaporator coil. Verified all colored wiring connections at motor housing were secure and properly terminated. Inspected finned heat exchanger coil and noted dust and debris accumulation on aluminum fins, which is typical for seasonal operation. Checked blower housing mounting hardware and confirmed secure installation. Verified drainage pan condition and inspected surrounding mechanical components. All system components tested and operating within normal parameters with no deficiencies requiring immediate attention. Unit functioning properly upon completion of service visit.
Completed annual AC tune-up and system performance check on residential air conditioning unit. Outdoor condenser coil was heavily impacted with dirt and debris, restricting airflow, and was thoroughly cleaned during service. Return air filter was heavily loaded with particulate buildup and replaced with new filter. Upon inspection, evaporator coil displayed significant buildup and debris accumulation along fins and surfaces, reducing heat transfer efficiency and restricting airflow across the coil. Documented condition with photographs showing contamination at coil base and ductwork seams. Recommended professional evaporator coil cleaning to restore optimal system performance and efficiency. Outdoor contactor exhibited visible wear, pitting on contact surfaces, and electrical degradation indicating imminent failure risk. Recommended contactor replacement to prevent system shutdown and ensure reliable operation during peak cooling season.
Performed comprehensive AC maintenance on two heat pump systems utilizing R-410A refrigerant under 85-degree ambient conditions. Conducted thorough inspection of all critical components including thermostats, temperature splits, condensers, evaporator coils, blower motors, capacitors, compressors, refrigerant levels, and condensate drains. Replaced air filters (20x25x5 and 14x25x1) on both units. Verified proper operation of all electrical connections, control boards, and safety devices. Both systems tested and confirmed operating within normal parameters upon completion of maintenance service.
Responded to callback for recurring loud clicking fan noise on Bradford White G2 50-gallon electric hybrid water heater. Unit was producing hot water but fan exhibited same failure symptoms as previous April 2026 repair. Contacted technical support to diagnose repeated fan component failure. Documented unit condition with photographs showing water heater installation, digital display panel, copper supply piping, PVC drainage lines, and overall mechanical room configuration. Ordered replacement fan assembly through manufacturer warranty to resolve ongoing noise issue.
Responded to service call for lavatory sink drain backup and shower head low pressure issues. Upon diagnostic inspection, verified the shower head was restricting flow due to internal debris buildup. Attempted to clear debris but pressure remained inadequate, determining shower head replacement will be necessary. Investigated lavatory sink drain and confirmed blockage, likely caused by hair accumulation. Additionally identified a dripping cold side faucet caused by worn cartridge and a continuously running toilet due to faulty fill valve requiring replacement. Performed drain cabling on lavatory sink, successfully extracting hair ball obstruction from the line. Tested drain flow and verified proper operation restored. Removed and replaced toilet fill valve assembly, testing to confirm toilet now functions correctly without continuous running. Removed and replaced cold side faucet cartridge, verifying elimination of drip and proper operational function. All completed repairs tested and
Performed comprehensive maintenance on two mini-split condensers with two indoor head units each. Inspected and evaluated filters, thermostats, temperature differential, condensers, and drain systems on all units. All systems tested and confirmed operating within normal parameters. Identified mold buildup on blower wheel in one indoor head unit requiring deep cleaning. Provided recommendation for professional head unit cleaning service, which was approved for scheduling at a later date.
Responded to no-gas condition at water heater following recent gas line installation. Upon arrival, confirmed water heater was not receiving gas supply and pilot would not ignite. Inspected gas supply piping, shut-off valve, and connections to the unit. Identified gas supply issue preventing proper operation of the water heater. Documented existing equipment condition, including aged plumbing components with visible corrosion on brass fittings and shut-off valve assembly. Provided replacement options and pricing for new water heater installation to restore hot water service to the property.
Responded to no cooling call at commercial building following previous visit where unit was tagged out due to cracked heat exchanger. Upon arrival, found furnace and air conditioning system inoperative with low voltage power error code displayed. Diagnosed blown fuse as cause of system failure, inspected all wiring to verify no damaged conductors or short circuits present. Replaced failed fuse, restored power to system, and cycled both furnace and condenser through complete operational test to confirm proper function of all components.
Completed annual cooling tune-up on single heat pump system. Performed comprehensive inspection of outdoor condenser unit and indoor Daikin air handler with all components operating within normal parameters. Exterior unit shows significant weathering and surface corrosion on cabinet panels but remains functionally sound with no performance issues identified. Verified refrigerant lines, electrical connections, condensate drainage, and PVC venting all secure and properly configured. System tested and confirmed running efficiently with no service concerns noted at this time.
Completed annual cooling maintenance on one standard R-410A air conditioning system and one mini-split system with four heads under ambient conditions of 94°F. Performed comprehensive inspection of standard AC unit including filter, thermostat, temperature split, condenser coils, motors, capacitors, compressor, refrigerant charge levels, and condensate drain. Replaced 16x25x1 air filter and identified failing dual-run capacitor (45+5 MFD) testing below specifications. Upon approval, replaced defective capacitor with new unit, restoring system to proper operation. Conducted maintenance on mini-split system including inspection of filters, thermostat operation, temperature drop across evaporators, condenser unit, and drain lines across all four indoor heads. Both cooling systems tested and confirmed operating within normal parameters upon completion of maintenance procedures.
Completed annual cooling preventative maintenance visit on Daikin heat pump system with side discharge configuration. Performed comprehensive AC tune-up on outdoor heat pump unit and indoor air handler located in attic space. Conducted full system inspection, verified refrigerant charge, checked electrical connections, tested thermostat operation, and confirmed proper airflow. All components operating within manufacturer specifications with no deficiencies noted.
Responded to no cooling complaint on R-22 refrigerant system installed in 2008. Diagnosed system as low on refrigerant with suction line frost buildup, low side pressure at 51 PSI with 3.9°F superheat and 27.2°F vapor saturation temperature, and high side pressure at 221 PSI with subcooling at 221°F and liquid saturation at 108°F. Found outdoor condenser coils heavily clogged with cottonwood debris restricting airflow. Advised homeowner to clean coils and scheduled estimate appointment for system replacement due to age and R-22 refrigerant phase-out considerations.
Responded to no cooling complaint with concerns about low refrigerant and frozen lines. Performed complete system diagnostic including refrigerant charge verification, component testing, temperature differential measurements, and visual inspection of all major components. All electrical components, control board, capacitor, and outdoor unit tested within manufacturer specifications. Refrigerant charge confirmed at proper levels with no freezing present on refrigerant lines. Air filter clean and outdoor coil free of debris. Temperature split across evaporator coil measured within acceptable range, confirming proper system operation. During inspection, discovered broken supply plenum above evaporator coil leaking conditioned air into basement area, which is likely causing inadequate airflow to upper levels of residence. This ductwork failure explains reduced cooling performance despite properly functioning equipment. Customer scheduled independent duct cleaning company to inspect for ad