Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in July 2026.
The most recent job was on July 23, 2026.
Hurlburt Heating & Plumbing has completed 1,700 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Completed Member A/C tune-up on outdoor condensing unit less than 10 years old. Performed comprehensive maintenance inspection of beige cylindrical condenser positioned on concrete pad adjacent to brick building. Unit showed no operational issues or deficiencies during inspection. All components including fan motor, compressor, and refrigerant lines functioning within normal parameters.
Completed follow-up visit after initial morning appointment when customer was not home. Returned later to gather necessary information and document site conditions with photographs. Created and emailed detailed proposal to customer for review and approval.
Delivered two Glasfloss 14x30x1 air filters to the residence as requested. Made contact with tenant at the back door and handed off the filters directly to ensure proper receipt and protection from weather exposure.
Completed annual cooling maintenance on one Lennox heat pump system utilizing R-410A refrigerant with ambient temperature at 73 degrees. Performed comprehensive inspection including air filter, thermostat operation, temperature split across evaporator coil, condenser unit, coil cleanliness, blower motor, capacitors, compressor amperage, refrigerant charge levels, and condensate drain line. All components inspected and tested within normal operating parameters with no deficiencies identified. System confirmed operating properly upon completion of preventive maintenance visit.
Responded to loss of cooling capacity complaint on residential R-22 air conditioning system. Previous service provider had replaced capacitor but did not address refrigerant charge. Performed system inspection and confirmed unit was low on R-22 refrigerant. Discussed with homeowner the implications of R-22 phase-out, limited availability, and increasing costs associated with maintaining older systems using this refrigerant. Recommended full system replacement as the most cost-effective long-term solution given the refrigerant type and system condition. Homeowner elected to obtain replacement estimate from previous service provider first due to existing discount offer, with option to request second quote if desired. No repairs performed at this time.
Responded to service call for loud banging noise occurring when AC unit starts up. Diagnosed excessive blower speed on 2-ton system causing ductwork to collapse inward and create popping sound despite proper duct breaks on all sides. Adjusted factory blower setting from excessive CFM to proper 850 CFM for system capacity, which eliminated the noise issue. Performed refrigerant charge verification and identified R22 refrigerant level is low. Scheduled follow-up appointment with service advisor as company policy no longer services R22 refrigerant systems.
Completed city certification inspections on one boiler and two of three furnaces across a four-unit property. The fourth furnace could not be certified due to lack of electrical power to the unit, requiring coordination with an electrician before returning to complete the final inspection.
Performed preventive maintenance agreement tune-up on 1-year-old Lennox air conditioning system. Inspected contactor and inverter board, both operating within normal parameters. Verified refrigerant charge at proper levels. Removed access panels and pressure-washed outdoor condenser coil to remove debris and improve heat transfer efficiency. Replaced heavily soiled furnace filter with new filter. Inspected evaporator coil, found clean with no buildup. Measured supply and return air temperatures, confirmed system achieving 20-degree temperature differential, which is within manufacturer specifications. All components functioning as designed with no deficiencies noted or recommendations required at this time.
Responded to exterior hose bib leaking issue at residential property. Upon inspection, found outdoor spigot with deteriorated connections and corroded fittings causing water spray during operation. Identified that attached garden hose was contributing to leak at connection point. Removed garden hose from hose bib to isolate leak source. Assessed vertical pipe assembly and valve configuration, noting weathered components and evidence of previous repair attempts. Documented existing plumbing setup including multiple threaded connections, valve with control handles, and overall condition of exterior water supply system for recommended replacement or further repair.
Performed annual maintenance on five HVAC systems including four central air conditioning units and one single-head mini split system. Completed comprehensive tuneups on all units, verifying proper operation of compressors, capacitors, refrigerant levels, and electrical connections. Shut down humidifiers for the cooling season and installed one customer-supplied furnace filter on primary system. All five systems tested and confirmed operating within normal parameters upon completion of maintenance visit.
Completed annual cooling maintenance on two R-410A air conditioning systems with ambient temperature at 78 degrees. Performed comprehensive inspection of both units including filters, thermostats, temperature splits, condensers, coils, motors, capacitors, compressors, refrigerant levels, and condensate drains. Main floor AC unit found operating within normal parameters with no deficiencies noted. Basement/upstairs AC unit currently cooling adequately but diagnosed as low on refrigerant with potential leak present. Provided repair estimates for refrigerant recharge and leak detection service; homeowner declined repairs at this time and will monitor system performance.
Performed comprehensive inspection on Rheem tankless water heater serving as the primary heating component for both domestic water and air systems. Conducted visual examination of unit exterior, confirming no visible leaks, damage, or areas of concern. Initiated startup procedure to verify operational functionality, listening for irregular sounds and monitoring performance parameters, which indicated proper operation. Upon consultation with homeowner, determined unit had never been descaled since installation. Executed complete descaling procedure using appropriate chemical solution to remove mineral buildup from heat exchanger and internal components. Connected descaling pump and circulated descaling agent through the system per manufacturer specifications to restore optimal heat transfer efficiency and extend equipment lifespan. Following descaling process, performed thorough system flush to remove residual descaling solution and loosened mineral deposits. Verified all plumbing con
Performed annual preventive maintenance cooling visit on 14-year-old residential air conditioning system. Completed comprehensive tune-up including thorough cleaning of outdoor condenser coils to ensure optimal heat transfer and system efficiency. Verified refrigerant charge levels are within manufacturer specifications with no leaks detected. Conducted full system inspection with all components—including compressor, fan motor, contactors, capacitors, and electrical connections—operating properly and within normal operating parameters. System is fully operational with no deficiencies noted. Recommended maintaining thermostat setting at 76°F or lower to keep indoor relative humidity below 60% for optimal comfort and equipment performance.
Responded to water leak originating from main floor bathtub and draining into basement below. Upon inspection, identified failed galvanized tub drain as source of leak. Water damage restoration company had been previously contacted. Documented existing conditions with photographs of basement mechanical room showing proximity of leak to HVAC equipment and water heater. Diagnosed deteriorated galvanized drain piping requiring replacement. Provided estimate for replacement of affected drain section. Additionally assessed two-handled tub valve and provided bid for valve replacement with remodel plate to accommodate proper access and modernize fixture controls.
Completed annual cooling maintenance agreement visit servicing one R-410A air conditioning condenser and one air exchanger unit. Performed comprehensive AC tune-up including inspection and testing of filter, thermostat, temperature split, condenser coils, motors, capacitors, compressor, refrigerant charge levels, and condensate drain with ambient temperature at 79 degrees. Conducted full maintenance on air exchanger including cleaning and vacuuming of filter and core, drain inspection, and cleaning of intake and exhaust outdoor components. All systems tested and confirmed operating within normal parameters upon completion.
Performed comprehensive furnace and air conditioning system inspection for residential property sale compliance. Conducted thorough evaluation of 11-year-old Carrier HVAC system including both heating and cooling components. **Furnace Inspection:** Inspected burner assembly and confirmed proper operation with clean flame pattern. Verified flame sensor functionality and proper signal strength. Evaluated blower motor operation and confirmed adequate airflow throughout system. Performed combustion analysis with digital analyzer, recording carbon monoxide levels at 20 ppm (within acceptable range), oxygen at 10%, carbon dioxide at 5.9%, and steady state efficiency at 98%. All combustion parameters met manufacturer specifications and safety standards. Confirmed proper furnace operation through complete heating cycle. **Air Conditioning Inspection:** Evaluated outdoor condensing unit components and electrical systems. Tested run capacitor with digital meter, measuring 32.9 microfarads agai
Performed comprehensive cooling tune-up on 11-year-old high velocity AC system located in attic. Inspected and verified contactor, capacitor, and amp draws all operating within normal parameters. Cleaned condenser coil and confirmed air filter, blower assembly, and evaporator coil were clean. Verified refrigerant charge and temperature drop at 20 degrees, meeting manufacturer specifications. Note: refrigerant readings slightly affected by ambient outdoor temperature below the 70-degree minimum required for optimal high velocity system operation. All components functioning properly with no deficiencies identified or recommendations needed at this time.
Responded to water leak causing basement flooding from upstairs bathroom. Identified source as failed caulking and grout deterioration around bathtub tile joints and soap dish fixture. Removed old caulking, cleaned and prepared surfaces, and re-caulked all tile joints to create proper water barrier and prevent further water intrusion into basement below.
Responded to service call for Bradford White tanked water heater with pilot light failure and no hot water production. Upon arrival, found unit displaying same error code as previous service visit, indicating pilot would not remain lit. Successfully re-lit pilot light and restored hot water operation. Advised homeowner that pet litter boxes in immediate vicinity of water heater may be contributing to air quality issues affecting combustion and pilot light stability, and recommended relocating litter boxes away from appliance to prevent future occurrences.
Completed annual spring cooling maintenance on one R-410A air conditioning system and one heat recovery ventilator (HRV) under preventative maintenance agreement. Performed comprehensive AC tune-up including inspection and testing of filter, thermostat, temperature split, condenser unit, evaporator coils, motors, capacitors, compressor, refrigerant charge, and condensate drain line with ambient temperature at 68°F. Conducted full HRV maintenance including interior cleaning, core and filter vacuuming, drain inspection, and cleaning of exterior intake and exhaust vents. All electrical components tested and verified operational, refrigerant levels confirmed within specifications, and both systems operating within normal parameters at completion of service visit.