Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in July 2026.
The most recent job was on July 24, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Performed scheduled preventive maintenance on three commercial rooftop HVAC units located approximately 15 feet above ground level. Upon arrival, verified all units were operating properly with thermostats satisfied. Replaced return air filters with 16x25x2 filters on all three rooftop units. Cleaned condenser coils on each unit using hose and backpack sprayer with water supply accessed from front building spigot. Tested and verified proper fan operation and cooling functionality on all three units following maintenance completion.
Responded to water leak in second-floor bathroom shower. Accessed property using provided entry code with authorization to complete work in absence of occupant. Removed existing dual valve shower system that was causing leak. Installed two owner-supplied Delta shower valves as replacements. Wall required demolition to access plumbing connections, exposing copper supply lines and drain pipes within stud cavity. Completed valve installation and verified proper operation with no active leaks upon completion.
Completed annual cooling maintenance on a 3-year-old high velocity air conditioning system consisting of one air handler and one condensing unit. Performed comprehensive tune-up including refrigerant pressure and temperature measurements using digital manifold gauges, which confirmed proper refrigerant charge levels. Inspected and verified all system components are operating within manufacturer specifications. System is fully operational as designed. Noted basement area lacks supply vents in current configuration, resulting in limited cooling to that space; recommended mini-split system installation as potential solution for basement climate control.
Responded to water leak complaint affecting basement bathroom ceiling. Upon inspection, identified active leak originating from Whirlpool dishwasher located on floor above. Water damage evident on bathroom ceiling with peeling paint and sagging material. Determined dishwasher leaks during operation cycle. Documented conditions with photos showing affected dishwasher unit and resulting ceiling damage. Advised customer that dishwasher replacement is necessary to resolve leak issue.
Responded to recurring toilet flushing issue where customer had to manually operate flush valve inside tank. Upon inspection, determined that previous handle replacement was incompatible with existing flush valve mechanism, preventing proper actuation. Removed incorrect handle assembly and installed manufacturer-specified replacement handle compatible with the flush valve system. Tested flush operation multiple times to verify proper function and full tank drainage. Toilet now operates normally without requiring manual intervention.
Completed annual cooling maintenance on one 2-ton Carrier air conditioning system utilizing R-410A refrigerant. Performed comprehensive inspection including filter, thermostat, temperature split, condenser unit, evaporator coils, blower motor, capacitors, compressor, refrigerant charge, and condensate drain line. Identified filter with excessive MERV rating and recommended homeowner switch to MERV 11 for optimal airflow. Discovered blower speed settings were incorrectly configured for system tonnage, resulting in improper air delivery. Adjusted blower speed to manufacturer specifications to match 2-ton capacity requirements. Verified all electrical components operating within normal parameters using digital multimeter. System now functioning properly with correct airflow and temperature differential.
Replaced one zone damper motor in multi-zone HVAC system. Upon installation, discovered improper wiring configuration where two zone motors were wired together, preventing both dampers from operating correctly. Troubleshot the issue by disconnecting shared wiring and ran dedicated wire from control board directly to each motor, restoring proper independent operation. System tested and confirmed functional. Identified two additional zone damper motors showing signs of failure during inspection and provided estimate for replacement of remaining defective motors to prevent future system issues.
Responded to no cooling complaint on Carrier air conditioning unit. Found contactor severely burned out with visible heat damage and white residue accumulation on the component body. Replaced failed contactor with new unit per PO# 241292-001. During troubleshooting, discovered compromised wiring that appeared damaged beyond the immediate connection point. Attempted to isolate and remove affected wire section, but determined the entire wire run may require replacement for safe, reliable operation. System restored to operational status with new contactor installed, though wiring concern was noted for future service consideration. Total service time approximately 2 hours.
Completed programming and configuration of ChargePoint Home Flex electric vehicle charging station on existing 240-volt circuit for 2022 Kia Sorento. Verified proper operation of charger and confirmed connectivity with ChargePoint mobile application using account code AcclathomeMN. Documented installation with photos of electrical panel showing proper labeling and vehicle charging interface.
Removed and replaced existing toilet with new Gerber Avalanche elongated model featuring 1.6 GPF flush capacity. Completed full installation including setting the fixture, connecting water supply line, and testing flush mechanism for proper operation and seal integrity.
Completed annual cooling maintenance on one R-410A air conditioning system as part of membership tune-up agreement. Performed comprehensive inspection of condenser unit, evaporator coils, motors, capacitors, compressor, and refrigerant levels with ambient temperature at 79 degrees. Verified proper thermostat operation, temperature split, condensate drain function, and installed homeowner-provided 20x30x1 air filter. All system components tested within normal operating parameters with no deficiencies identified at time of service.
Responded to service call for toilet backing up and overflowing in upstairs bathroom of 1925 craftsman home, causing water damage to basement below. Inspected existing toilet installation and identified failed toilet bend requiring replacement. Assessed plumbing system and determined need for 14" rough-in toilet replacement. Provided comprehensive estimate covering new toilet installation, toilet bend repair, complete drain line repipe, and water supply line repipe to address underlying plumbing issues in older home. Documented existing bathroom conditions and basement mechanical area. Scheduled follow-up installation work.
Completed certified safety inspection on residential furnace and HVAC system for rental property compliance. Performed comprehensive evaluation of heating equipment, water heater, venting systems, and thermostat operation. Inspected flue pipe assembly, ductwork, and exhaust connections for proper installation and safety. Verified thermostat functionality showing proper display and control settings. Examined all mechanical components including gas lines, electrical connections, and safety controls. All systems passed inspection with no deficiencies noted. Certification letter generated and provided for rental licensing requirements.
Responded to service call for bedroom above unheated garage experiencing inadequate heating in winter and excessive heat in summer. Assessed room conditions and determined insufficient insulation and lack of proper climate control as primary issues. Documented existing electrical panel configuration and available circuit capacity for potential supplemental baseboard heating system installation. Provided estimate for adding supplemental baseboard heat/cooling system to address temperature control deficiencies in the affected space.
Responded to a call for a cracked PVC fitting on an exposed irrigation line. Upon arrival, identified a damaged white PVC pipe fitting with a vertical crack and discoloration from age and mineral deposits. Removed the failed fitting and installed a new PVC connector to restore system integrity. After installation, activated the irrigation system and conducted a 10-minute pressure test to verify proper operation and confirm no leaks were present. System was left in full service with all components functioning correctly.
Responded to gas leak emergency where the utility company was on-site and had identified multiple gas leaks on both HVAC units' gas lines. Documented all leak locations marked by the utility company, including a pinched copper gas line behind the oven requiring replacement. Photographed the affected gas piping connections, valves, and compromised copper lines showing visible damage to the gas supply infrastructure. Verified the residence was properly ventilated for safety. Completed comprehensive documentation of all required repairs including gas line replacement and leak remediation work. Submitted detailed follow-up documentation with photographic evidence for estimate preparation and scheduling of installation work.
Responded to multiple plumbing issues including a leaking outdoor hose spigot, backed-up floor drain, and deteriorating laundry tub requiring replacement. Upon inspection, determined the existing hose spigot and valve had failed seals and the unit was not frost-free, creating vulnerability to freeze damage. The floor drain was obstructed with accumulated debris in the trap and drain line. Cleared the floor drain by cabling and vacuuming all debris from the trap and line, then performed a water flow test to verify proper drainage. Removed the failed hose spigot and valve assembly, then installed a new frost-free spigot with a new ball valve equipped with bleeder. Tested the new installation for proper operation and confirmed all components were functioning correctly with no leaks present.
Completed comprehensive air conditioning tune-up on R-22 system with indoor air handler located in attic and outdoor condenser unit. System was found to be low on refrigerant charge; identified leak, evacuated remaining R-22, and recommended full system replacement due to obsolete refrigerant type and age of equipment.
Performed comprehensive AC tune-up on 11-year-old air conditioning system. Verified refrigerant levels within proper range and confirmed all components operating within manufacturer specifications. Conducted electrical diagnostics using digital multimeter, identifying capacitor reading at lower end of acceptable range. Replaced capacitor as preventative maintenance measure to ensure continued reliable operation. System tested and confirmed fully operational upon completion.
Completed Member A/C tune-up on outdoor condensing unit less than 10 years old. Performed comprehensive maintenance inspection of beige cylindrical condenser positioned on concrete pad adjacent to brick building. Unit showed no operational issues or deficiencies during inspection. All components including fan motor, compressor, and refrigerant lines functioning within normal parameters.