Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in July 2026.
The most recent job was on July 28, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Installed standpipe for HVAC condensate pump in mechanical room adjacent to bathroom. Cut into bathroom wall to access existing ABS lavatory drain line. Used combo glue to connect new PVC wye fitting to ABS drain and installed PVC trap for condensate line connection. Tested installation by running water through sink drain to verify no leaks were present. Secured standpipe and condensate drain line from pump to new standpipe connection. Left condensate pump and drain system operational and in service.
Performed deep cleaning service on two Mitsubishi ductless mini-split indoor heads. Thoroughly cleaned blower wheels, evaporator coils, and unit covers to remove accumulated dirt and debris. Verified proper operation of both systems following cleaning. All units are operating within normal parameters.
Responded to no cooling call on 5-year-old A/C unit. Found wet switch tripped due to condensate overflow, cleared drain line, reset safety switch, verified proper cooling operation and electrical readings with multimeter.
Returned to address customer concerns regarding excessive noise and inadequate temperature control. Performed comprehensive system inspection including furnace airflow, air filter condition, temperature split analysis, and blower wheel speed verification. Conducted outdoor unit diagnostics with refrigerant level check, capacitor/contactor testing, coil inspection, and electrical component evaluation. Utilized decibel meter to measure operational sound levels, recording 63.5 dB which falls within normal operating parameters. All system components functioning properly with no abnormalities detected.
Completed annual cooling maintenance on a 2000 Lennox R-22 AC system and identified multiple critical components requiring attention. During inspection, discovered failing capacitor reading 28/2 MFD (rated 35/5 MFD) with visible residue on top, buzzing contactor, and low refrigerant charge with high side at 148 PSI (5°F subcooling, 81°F liquid saturation) and low side at 57 PSI (4.3°F superheat, 31°F vapor saturation). Performed standard maintenance procedures including air filter inspection, blower speed verification, condensate drain line flush, and exterior coil cleaning with 25-degree delta-T confirmed. Due to age of system and multiple failing components, scheduled follow-up appointment for system replacement estimate.
Completed annual cooling maintenance on one heat pump system with R-410A refrigerant under preventive maintenance agreement. Performed comprehensive inspection including filter, thermostat operation, temperature split measurements, condenser unit, evaporator and condenser coils, blower motor, capacitors, compressor amperage draw, and condensate drain line. All components tested and found operating within normal parameters with ambient outdoor temperature at 96°F.
Responded to emergency call for failed wall-mounted toilet fixture that completely separated from wall mounting system during use, causing the porcelain bowl to shatter. Removed damaged toilet bowl and assessed wall carrier system for structural integrity. Installed new wall-mounted toilet fixture with proper carrier mounting, ensuring secure attachment to wall framing and connection to existing flush valve assembly and waste line. Tested installation for stability and proper flush operation.
Responded to no cooling call on 8-year-old system that was unable to maintain setpoint, with indoor temperature rising from 74°F to 78°F. Upon inspection, discovered significant debris buildup on condenser coil restricting airflow and reducing heat transfer efficiency. Performed thorough coil cleaning to restore proper system operation and cooling capacity.
Responded to no hot water condition with pilot light failing to stay lit on tanked water heater. After multiple unsuccessful relight attempts, removed burner assembly and replaced faulty thermocouple. Reinstalled burner, successfully relit pilot light, and restored gas valve operation. Verified proper heating cycle operation through multiple on/off tests and left unit in full working service.
Responded to no cooling complaint where system was completely shut off and not communicating. Upon arrival, found wet switch safety had tripped, shutting down the air conditioning system. Dried out wet switch and restored system operation. Verified proper system communication and cooling functionality before departure.
Responded to refrigerant leaks detected at the service valves on the outdoor condensing unit. Reclaimed all existing refrigerant from the system, removed the failed service valves, and brazed in new replacement valves. Performed comprehensive leak check to verify system integrity, then evacuated the system to proper vacuum specifications. Recharged the system with 7 lbs 12 oz of R-410A refrigerant per manufacturer specifications. Cycled the equipment through multiple operational modes and verified all parameters within normal operating range. Unit restored to full operational status with all repairs completed under warranty coverage.
Responded to no cooling complaint with tripped breaker. Upon arrival, performed system inspection and found outdoor condenser unit operational but breaker repeatedly tripping under load. Inspected electrical components including capacitor and wiring connections. Determined circuit breaker was weak and unable to handle normal operating amperage of the air conditioning system. Documented equipment condition with photos showing outdoor unit, capacitor assembly, and electrical connections for diagnostic purposes and customer records.
Responded to service call for shower temperature issue and toilet replacement evaluation. Upon inspection, found incorrect trim and cartridge installation on shower valve causing lack of hot water. Adjusted temperature limiting mechanism on existing valve to restore proper hot water function. Assessed gravity-fed toilet with pull chain mechanism for replacement and provided estimate for new toilet installation. Evaluated exterior spigot requiring repair and provided bid for replacement. Documented existing conditions including vintage hexagonal tile flooring and current fixture configurations for future reference.
Completed return visit to perform maintenance cleaning on ductless mini split system. Thoroughly cleaned both indoor head units, removing accumulated dust and debris from evaporator coils and blower wheels. Cleaned outdoor condenser unit coils, removing dirt buildup and restoring proper airflow through heat exchanger fins.
Responded to no cooling complaint on Rheem unit. Upon arrival, confirmed system was not operating with no fan activity. Diagnosed failed fuse in outdoor disconnect switch. Removed old fuse and installed replacement, restoring power to unit. Verified system operation with cooling and proper fan function before completing service.
Responded to callback for water leak investigation in laundry room area with water penetrating ceiling below. Upon inspection, determined water was originating from water heater drain pan (unit serviced previous week) rather than washer connection. Identified clogged upstairs drain as contributing factor to water backup. Referred customer to specialized drainage technician for drain clearing service, as issue required dedicated drainage equipment and expertise beyond scope of plumbing repair.
Responded to callback for recently installed mini split systems reported not cooling properly with no condensate drainage from two south-side units. Upon arrival, all mini split units were operating normally with proper cooling and condensate flow observed. Inspected rooftop and exterior equipment, verified refrigerant pressures, airflow, and drainage systems on all units. No defects or malfunctions identified during diagnostic evaluation. Determined issue was likely due to user error or temporary condition that self-resolved prior to service visit.
Responded to no cooling complaint on 14-year-old Payne central air conditioning system with thermostat displaying "no power" error code. Upon arrival, verified thermostat wiring and control board were functioning properly. Discovered wet spot on air filter, prompting inspection of condensate drainage system. Found condensate drain line obstructed with debris and successfully flushed to restore proper drainage. Identified root cause as loose and improperly positioned float switch on drain pan, which had tilted downward and was triggering safety shutoff to thermostat. Repositioned and secured float switch to correct orientation, ensuring proper safety function if water accumulates in drain pan. Verified outdoor condensing unit operating normally with no issues detected. Tested system operation after repairs; unit now cooling properly with all components functioning as designed. Documented customer concern regarding intermittent ductwork rattling noise via video for future reference if is
Responded to no cooling complaint with water leaking on floor. Found tripped outlet supplying power to condensate pump, causing system shutdown and water overflow onto concrete floor. Reset circuit breaker and restored power to pump, which resumed normal condensation removal operation. Inspected unit and noted rust staining and water streaks on equipment and surrounding area from previous overflow. Verified Rheem furnace returned to normal operation, checked air filters, and confirmed condensate drain system functioning properly with pump actively removing water from drain pan.
Responded to no cooling call on 11-year-old residential AC system. Upon arrival, homeowner reported outdoor condenser fan running intermittently and stopping. Diagnosed failed dual-run capacitor reading 32/0 MFD out of rated 35/5 MFD. Replaced defective capacitor with proper OEM replacement, restoring normal condenser fan operation. Performed complete system verification including contactor inspection, refrigerant charge analysis, air filter condition check, and temperature split measurements across evaporator coil. All parameters confirmed within manufacturer specifications. System returned to full cooling operation with no further issues detected.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.