Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in July 2026.
The most recent job was on July 30, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Responded to no cool complaint on residential property with two 16+ year old Carrier AC systems struggling to maintain temperature during hot weather. Performed diagnostic evaluation on both attic and basement units. **Attic Unit Findings:** Identified low refrigerant charge causing reduced cooling capacity. Observed partial evaporator coil freeze-up due to insufficient refrigerant levels. System operating outside normal parameters. Discussed repair options with homeowner and scheduled service advisor visit for comprehensive evaluation and refrigerant leak detection/repair recommendations. **Basement Unit Findings:** Tested capacitor and found weakened performance approaching failure threshold. All other components including compressor, blower motor, and controls operating within specifications. Verified refrigerant charge at proper levels. Measured supply and return air temperatures confirming 20-degree temperature split, within acceptable range for proper system operation. **Servi
Responded to no cooling complaint on attic-mounted mini split unit. Found condensate drain line and tube completely plugged, causing flood switch to trip and shut down system. Cleared blockage using vacuum from both interior and exterior access points, removed standing condensation water, and reset flood switch. Verified proper drainage operation and confirmed unit returned to normal cooling function. Inspected filters and found them in acceptable condition with replacement recommended for late August. Measured supply air temperature at 46.8°F, confirming adequate cooling performance post-repair.
Completed comprehensive annual maintenance agreement service on residential furnace and air conditioning system. Performed full furnace inspection including filter check, carbon monoxide testing, temperature split analysis, burner examination, flame sensor inspection, igniter assessment, motor and capacitor evaluation, drain line check, heat exchanger inspection, and gas pressure verification—furnace operating within normal parameters. Conducted complete AC maintenance with ambient temperature at 77 degrees on R22 refrigerant system, including filter inspection, thermostat calibration, temperature split measurement, condenser examination, coil cleaning and inspection, motor and capacitor testing, compressor evaluation, refrigerant charge assessment, and condensate drain verification. Identified aging capacitors (35mfd and 4mfd) requiring replacement and low refrigerant charge; recommended system replacement due to advanced age, obsolete R22 refrigerant type, and undercharge condition—r
Responded to warranty callback for recently installed HVAC system to address excessive outdoor unit noise, inadequate dehumidification with indoor humidity levels consistently reading 61-72%, and water leakage from basement ductwork with accompanying mold odor. Inspected condenser unit operation and sound levels, evaluated airflow and refrigerant charge, examined ductwork for condensation issues and proper insulation, and assessed drain line functionality. Provided system operation training to homeowner on thermostat controls and dehumidification settings.
Responded to no cool complaint on Lennox system displaying lockout fault with Alarm ID 411 for outdoor unit low pressure switch strikes. Verified adequate indoor airflow and inspected air filter condition. Performed comprehensive visual inspection of evaporator coil, condenser coil, and compressor area for refrigerant leakage using UV dye detection method with no leak source identified during inspection. Checked refrigerant circuit and confirmed system operating with low refrigerant charge, indicating probable leak that is not visually detectable at this time. Temporarily restored system operation. Rescheduled for further diagnostics and leak detection to identify refrigerant loss source and complete repairs under warranty coverage.
Completed annual cooling maintenance visit on residential HVAC system including one central air conditioning unit and two mini split systems accessed through attic/playroom area. Performed comprehensive tune-up procedures on all equipment, replaced 16x25x3 filter on main Lennox furnace unit, and verified proper operation of all three thermostats throughout the property with all systems found to be functioning within normal parameters.
Responded to service call for broken shower fixture requiring faucet replacement. Upon inspection, identified severely corroded shower valve stem and deteriorated mounting assembly with extensive rust damage affecting surrounding tile area. Documented existing conditions showing failed valve cartridge with compromised seals and oxidized metal components. Submitted parts order form for replacement shower valve assembly and necessary hardware to complete installation at owner-occupied residence.
Responded to no cool call on 16-year-old Bryant air conditioning system. Diagnosed low refrigerant charge (410A), failed fan capacitor, and dirty condenser coil. Verified adequate airflow from air handler and confirmed filter was not restrictive. System currently maintaining acceptable temperatures with evaporator coil not yet reaching freezing point. Provided customer with repair options and scheduled follow-up service advisor appointment for system evaluation and recommendations.
Responded to install callback for newly installed boiler that would not power on and was repeatedly blowing 5 amp fuses, leaving property without hot water. Performed diagnostic troubleshooting and isolated issue to failed transformer inside boiler unit. Verified transformer had continuity but failed to operate properly under load. Confirmed fuse operated correctly when transformer was disconnected from circuit. Documented findings with photos of blown fuse and internal wiring configuration. Unit requires transformer replacement to restore operation.
Responded to kitchen faucet with malfunctioning toggle button stuck in spray mode. Diagnosed faulty sprayer head assembly requiring replacement and provided repair estimates to customer.
Completed seasonal AC tune-up and maintenance agreement service on unit. Responded to reported burning smell from vents; inspected system thoroughly and replaced air filters. Performed temperature measurements and system diagnostics, confirming proper operation with no issues found at time of service.
Responded to no cooling call with reported power issues following utility outage. Upon arrival, found outdoor unit not receiving 240V power supply. Attempted to restore power by resetting breaker, which resulted in loud arcing and tripped main electrical panel for entire residence. Inspection revealed compressor had sustained electrical damage from previous arcing event reported by homeowner. Outdoor condenser coils found extremely dirty and clogged with debris, restricting airflow and contributing to system stress. Heavy rust and corrosion noted on protective grille and wire guard. Unit displayed signs of electrical shock damage to compressor components. Due to severity of electrical failure and compressor damage, system deemed unsafe to operate. Documented conditions with photographs showing deteriorated coil condition and overall unit neglect. Scheduled comfort advisor appointment for same day between 12-2pm to provide system replacement options and cost estimates for customer consi
Responded to no cooling complaint on 6-year-old Lennox air conditioning system following recent compressor and evaporator coil replacement. Upon arrival, diagnosed system as low on refrigerant charge, indicating active leak in refrigeration circuit. Recharged system to manufacturer specifications and injected UV leak detection dye with sealant into refrigerant lines. Sealant may seal minor leak; scheduled follow-up leak search appointment in four weeks to verify system integrity and locate any remaining leaks if necessary.
Completed annual cooling maintenance on two systems: central air conditioning unit and mini-split system with three heads. Performed comprehensive AC tuneup including system diagnostics and temperature readings in ductwork, which measured 55.5 degrees at supply plenum. Identified weak capacitor on central air unit and replaced with new component to ensure reliable system operation. Inspected all ductwork, insulation, and connections in attic space. All systems tested and operating within normal parameters upon completion.
Responded to no cool call affecting entire home. Diagnosed faulty thermostat as cause of system failure. Removed defective thermostat and installed replacement unit, restoring proper communication between thermostat and air conditioning system. Verified system operation and confirmed cooling restored to all areas of home.
Responded to no cooling complaint on 2019 Mitsubishi mini split system with previous motherboard replacement history from 2022. Performed diagnostic testing and pressure checks using manifold gauge set, which revealed low refrigerant charge as the cause of insufficient cooling. Added refrigerant to restore system to proper operating levels and verified cooling performance upon completion.
Completed phone follow-up regarding safety form documentation required for job file. Contacted project coordinator to confirm proper safety form will be completed and returned for attachment to work order. Documented mesh filter/screen components on-site through photographic records showing cylindrical HVAC filtration elements in good operational condition.
Responded to callback for furnace water leak following previous A/C repair. Diagnosed disconnected condensate pump discharge hose causing water to leak from unit bottom. Reattached condensate hose to proper connection point and verified proper drainage to sink with water test. Tested electrical circuit and condensate pump operation, confirming normal function with no additional issues found.
Responded to no cooling complaint on 4-year-old A/C system. Upon inspection, identified clogged condensate drain line as suspected cause of issue. Cleared blockage from condensate drain system and verified proper drainage flow. Inspected condensate safety switch operation to ensure unit would resume normal cooling function. System tested successfully after service and returned to proper cooling operation.
Installed standpipe for HVAC condensate pump in mechanical room adjacent to bathroom. Cut into bathroom wall to access existing ABS lavatory drain line. Used combo glue to connect new PVC wye fitting to ABS drain and installed PVC trap for condensate line connection. Tested installation by running water through sink drain to verify no leaks were present. Secured standpipe and condensate drain line from pump to new standpipe connection. Left condensate pump and drain system operational and in service.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.