Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in August 2026.
The most recent job was on August 10, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Removed existing bathroom vanity and disconnected plumbing fixtures in preparation for bathroom remodel. Coordinated installation scheduling with project manager for new faucet and vanity replacement in owner-occupied residence.
Responded to phone follow-up regarding water accumulation in HVAC drain pan. Inspected unit interior components, control board, wiring connections, and drainage system. Documented current system condition with photos of electrical panel and internal components for customer records and provided technical guidance to address drainage concern.
Performed scheduled AC tune-up and inspection on Unico system with 2023 condenser model. No occupant was available on-site during the service visit. Completed standard maintenance protocol and documented equipment condition through photographic records of property access points.
Responded to a callback on a Lennox system installed two days prior with no cooling and freezing conditions. Diagnosed low airflow and excessive high-side pressure due to refrigerant overcharge. Recovered refrigerant from system, performed evacuation to remove moisture and non-condensables, then recharged unit to manufacturer specifications. System restored to proper operation with correct pressures and airflow.
Completed annual heating and cooling maintenance on 12-year-old Payne HVAC system utilizing R-410A refrigerant. On furnace, scrubbed burners and flame sensor, inspected heat exchanger with no defects found, verified capacitor, blower motor, control board, and all wiring connections in proper working condition. Confirmed CO levels within safe parameters and measured supply air temperature delta at 53 degrees, indicating optimal heating performance. Replaced air filter and confirmed unit ready for winter operation. On air conditioning system, inspected outdoor unit capacitor, contactor, and refrigerant charge—all within manufacturer specifications. Rinsed condenser coils to remove debris, verified 19-degree temperature split across evaporator coil, and confirmed condensation drain line flowing freely. Both systems operating efficiently with no issues identified.
Replaced existing thermostat with new Lennox S40 smart thermostat connected to SmartHub system under full warranty coverage. Initial installation completed with thermostat mounted and wired to control board, however communication error detected between thermostat and SmartHub requiring troubleshooting and rescheduling. Assisted with initial setup and programming of temperature settings, left equipment on-site for completion of SmartHub connectivity during follow-up appointment.
Responded to no hot water complaint on 8+ year old gas water heater with pilot light that would not relight. Upon arrival, found gas supply had been locked out by gas company. Coordinated gas service restoration and successfully relit pilot light, restoring hot water to the residence. Replaced aging unit with new high-efficiency gas water heater featuring digital display and safety controls. Installed expansion tank, connected copper supply lines with brass fittings, and ensured all connections met code requirements. Tested unit operation and verified proper heating function before completion.
Performed routine HVAC maintenance and safety inspection on a 15-year-old Aire-Flo furnace system at a duplex rental property to comply with municipal safety requirements. Conducted comprehensive safety checks of all system components, including heat exchanger inspection with photographic documentation submitted for secondary review, which confirmed no cracks or structural defects present. System found to be operating properly with no issues identified; unit cleared for continued safe operation.
Completed annual air conditioning maintenance on a 9-year-old system operating within normal parameters. Performed comprehensive inspection including air filter, blower speeds, and condensation pump, all found in good condition. Cleaned outdoor condenser coils, inspected contactor, capacitor, and electrical connections with no issues noted. Verified refrigerant charge at proper level with system achieving 21-degree temperature differential, confirming optimal cooling performance.
Responded to service call for malfunctioning floor drains at commercial property. Upon inspection, identified two separate issues requiring immediate attention: first floor drain missing functional cleanout cap, second floor drain completely obstructed with accumulated rust debris. Installed new cleanout cap on first floor drain and performed operational testing to ensure proper sealing and functionality. Addressed second floor drain by removing grate assembly to access blockage. Found drain bowl filled with heavy rust accumulation preventing water flow. Removed rust debris using vacuum extraction method to clear basin area. Performed mechanical cable cleaning of affected drain line to restore flow capacity and remove any remaining obstructions in the pipe. Successfully cleared blockage and verified line was flowing properly. Conducted final testing by flushing multiple buckets of water through both floor drain systems to confirm complete restoration of drainage function and proper o
Completed comprehensive tune-up and maintenance on 7-year-old furnace and 15-year-old air conditioning system. Performed full inspection of furnace, confirming all components operating within manufacturer specifications, proper gas pressure, safe CO levels in flue, and clean internal components. Conducted thorough AC system evaluation, identifying dirty outdoor coils restricting airflow and reducing system efficiency, along with failing capacitor. Cleaned outdoor condenser coils to restore proper airflow and operational efficiency. Replaced failing capacitor with new unit rated at 370+25 MFD to ensure reliable compressor and fan motor operation. Installed customer-supplied smart thermostat and configured system for proper operation. Verified refrigerant charge levels appropriate for system requirements. All systems tested and confirmed fully operational upon completion.
Completed annual cooling maintenance visit on residential air conditioning system. Performed comprehensive tune-up including inspection of outdoor condenser unit and indoor air filtration system, verified proper operation of all components, and confirmed system performance with no issues identified.
Responded to water leak at main service line shutoff valve. Upon inspection, found severely corroded vertical pipe assembly with extensive rust deterioration throughout the central section and compromised structural integrity at the base mounting platform. The main shutoff valve and surrounding piping exhibited advanced corrosion requiring immediate attention to prevent catastrophic failure. Additionally assessed drainage issues under kitchen sink and discussed potential garbage disposal installation. Documented existing conditions with photographs and provided estimate for main service line repair to address the active leak and prevent further water damage.
Performed comprehensive maintenance on 2-year-old residential air conditioning system utilizing 410A refrigerant under 83-degree ambient conditions. Conducted thorough inspection of indoor air handler including filter condition, condensate drain line, blower motor operation, and all electrical wiring and components. Verified proper temperature split across evaporator coil. Inspected outdoor condensing unit including condenser coil cleanliness, capacitor condition and ratings, and electrical connections. Measured and recorded amperage draw on condenser fan motor, compressor, and contactor to verify equipment operating within manufacturer specifications. Verified proper refrigerant charge and system pressures. All components found operating within normal parameters. System confirmed operational and cooling effectively at time of service completion.
Responded to callback for mini split system not cooling after refrigerant was added during previous service visit. Upon inspection, determined that refrigerant charge only lasted approximately one day, indicating active leak in system. Performed thorough leak detection on both outdoor and indoor unit components, including inspection of copper refrigerant lines, coil assemblies, and connection points. Diagnostics confirmed refrigerant leak is located within the indoor evaporator unit based on rapid loss of charge and visual inspection findings. Provided customer with repair estimate for leak repair and system recharge as backup option while they contact original installing contractor regarding warranty coverage.
Responded to no cooling complaint on Daikin system unable to maintain temperature below 73-74°F. Diagnosed failed main inverter board and replaced component under warranty, restoring proper system operation.
Responded to no hot water complaint on recently installed Navien boiler system. Found boiler pressure at 18 psi due to malfunctioning automatic fill valve preventing water from entering the system. Manually filled boiler to restore proper pressure and functionality, allowing system to produce hot water. Autofill valve requires replacement to prevent future low pressure issues and ensure automatic operation of the system.
Completed warranty replacement of thermostatic expansion valve (TXV) on a 2-year-old Lennox air conditioning system. Installed new TXV with sensing bulb properly mounted on horizontal suction line section and insulated per manufacturer specifications. Performed nitrogen pressure leak test, full system evacuation with decay test verification, recharged refrigerant to factory specifications, and confirmed proper system operation with all parameters within normal range.
Responded to no cooling call on residential air conditioning system. Upon arrival, found unit completely non-operational with no power to outdoor condenser. Inspection revealed severely corroded and deteriorated electrical connections at terminal block, with visible signs of arcing and heat damage. Cleaned corroded terminals, replaced damaged wire connections, and restored power to unit. System tested and confirmed operational with proper cooling function restored.
Completed phone follow-up regarding sconce installation inquiry. Customer requested clarification on whether installation of their sconces is included in the original bid or constitutes additional work. Documentation photos were taken for reference.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.