Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in August 2026.
The most recent job was on August 12, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Completed annual cooling maintenance visit on multi-system HVAC installation including basement furnace unit and rooftop condensing units. During inspection, identified weak capacitors affecting system performance. Replaced defective capacitors and installed hard start kits on compressors to improve starting efficiency and extend equipment lifespan.
Responded to a service call for a bathroom sink backing up in the upstairs bathroom. Upon diagnostic testing, the drain backed up after running water for a few seconds, indicating a blockage in the line caused by hair accumulation. Cabled the bathroom sink drain to approximately 20 feet and successfully removed hair buildup from the line. Tested the drain by running water while cleaning up the work area and verified proper drainage with no leaks or backup issues. All fixtures returned to normal operation.
Completed comprehensive air conditioning maintenance on 2018 unit as part of preventative maintenance agreement. Inspected and confirmed air filter in acceptable condition. Flushed condensation pump to ensure proper drainage operation. Addressed outdoor unit issue where creeping Charlie vegetation had infiltrated condenser coils. Removed plant material and thoroughly rinsed coils to restore optimal heat transfer efficiency. Performed electrical system diagnostics including capacitor testing with multimeter, contactor inspection, and complete wiring evaluation—all components operating within specifications. Verified refrigerant charge at proper level with no leaks detected. Measured system temperatures and confirmed unit cycling correctly. System operating efficiently and ready for continued seasonal use.
Completed annual maintenance on two mini split systems consisting of five total indoor head units (one system with two heads, one system with three heads) and two outdoor condensing units. Performed comprehensive service including cleaning air filters on all head units, flushing condensation drain lines, and inspecting blower wheels. Four head units showed clean blower wheels in good condition; one head unit exhibited heavily soiled blower wheel requiring cleaning, with customer opting for head unit replacement next year. Verified outdoor unit coils were clean on both condensers. Conducted delta-T testing on all units, confirming optimal cooling performance with 20-25 degree temperature differential across all zones. Documented equipment make, model, and serial numbers with photographs for service records. All systems operating within normal parameters.
Completed callback to correct gas piping installation to residential generator. Removed and replaced non-compliant black iron piping with code-approved materials, installed new gas regulator in improved location for proper clearances and accessibility, and replaced existing gas whip with correct specification flexible connector. Repositioned gas meter assembly and modified piping configuration to meet current code requirements, ensuring proper support and routing of all gas lines from meter to generator unit.
Completed membership A/C maintenance on two residential HVAC systems serving main level and third level zones. On both units, performed comprehensive system checks including evaporator coils, blowers, condensers, contactors, compressors, and refrigerant levels. Replaced air filters with homeowner-provided filters on both systems. Cleaned condenser coils on both units and serviced HRV units. Main level humidifier pad requires replacement at next fall maintenance visit, while third level humidifier pad is new. Cycled and tested all zone dampers; main level dampers operating normally, but identified one third-level damper motor operating roughly with potential failure risk. Provided estimate for damper motor replacement. Both systems confirmed in normal operation upon completion.
Responded to a leaking outdoor spigot issue where the front outside faucet was slowly dripping and not fully shutting off. Diagnosed the problem as a faulty Woodford stem that was not sealing properly. Replaced the defective stem with a new Woodford stem assembly and conducted multiple operational tests to verify complete shutoff and proper function. The faucet now operates correctly with no leakage and was left in full service.
Completed annual cooling tune-up and inspection on residential AC system. Performed comprehensive maintenance including checking refrigerant levels, testing electrical connections, inspecting condensate drainage, cleaning components, and verifying proper system operation. All equipment found to be functioning within normal parameters with no immediate repairs required.
Replaced defective control board and blower motor under parts warranty on HVAC system. Retrieved programming device to properly configure new control board, then completed installation of both components with all necessary electrical connections. Verified system operation and confirmed all functions working correctly upon completion.
Responded to a service call for a toilet that intermittently failed to flush properly. Upon inspection, diagnosed a faulty fill valve causing inconsistent tank refilling and flush performance. Removed the defective fill valve assembly and installed a new replacement unit. Tested the toilet through multiple flush cycles to verify proper operation and consistent refilling. System now functioning correctly with reliable flush performance.
Responded to a dripping shower faucet issue on a Delta Series 1700 Monitor single-handle tub/shower valve. Successfully replaced worn seats and springs to eliminate the drip and restore proper water shut-off function. The cartridge retaining ring was frozen but was able to complete the repair by replacing the internal components without full cartridge replacement.
Completed annual cooling tune-up on 19-year-old residential AC unit. Inspection revealed contactor in good condition, capacitor testing weak and nearing end of service life, amp draws within normal parameters, refrigerant charge at proper levels, clean air filter, 20-degree temperature split within specifications, and clean evaporator coil. During inspection, discovered cracked heat exchanger in gas furnace, requiring immediate safety shutdown per code requirements. Discussed equipment condition and replacement options with homeowner and scheduled follow-up consultation with service advisor.
Completed comprehensive annual maintenance agreement service including heating and cooling system inspections. Performed tune-up on one furnace, one air conditioning unit, one air exchanger, one humidifier, one boiler for radiant in-floor heating system, and two GFPs. Inspected all HVAC control boards, electrical connections, and capacitor assemblies. Verified proper operation of all heating and cooling components. Cleaned dryer vent as requested. All systems found to be clean, operating safely, and in good working condition with no deficiencies noted.
Responded to no hot water complaint affecting entire residence. Upon inspection, discovered 9-year-old water heater with partially melted gas valve, rendering unit unsafe for continued operation. Replaced failed water heater with new Rheem Performance Plus tanked gas water heater. Installed unit in basement utility area with proper copper piping connections, ensuring compliance with manufacturer specifications and safety standards. Verified all connections, tested system operation, and confirmed hot water restoration throughout the home.
Responded to a water leak under the bathroom sink caused by a corroded P-trap with a pinhole leak. The homeowner had already shut off the water supply to the sink to prevent further water damage. Upon inspection, confirmed the white P-trap had rusted through and was actively leaking. Removed the deteriorated P-trap assembly and installed a new chrome-plated P-trap with proper sealing connections. Verified all drain connections were secure and tested the system for proper drainage and leak-free operation. Restored water supply to the sink and confirmed no additional leaks were present in the supply lines or shut-off valves.
Responded to no cooling complaint on 9-month-old system with thermostat connectivity issues. Installed S40 control board, replaced malfunctioning thermostat, and rewired connections to integrate properly with new control board. Verified system operation with unit cooling effectively upon completion, and advised customer to report any further concerns.
Responded to service call for basement bathroom exhaust fan reported to be accumulating water. Upon inspection, no active leaking or moisture buildup was observed at time of visit. Examined ductwork routing and connections in ceiling space, verifying proper installation and support of flexible duct system. Customer indicated issue occurred intermittently on only a few occasions. Recommended use of dehumidifier to manage basement moisture levels and advised monitoring for future occurrences.
Performed comprehensive preventive maintenance on one residential air conditioning system utilizing 410A refrigerant under membership agreement. Conducted thorough inspection of indoor air handler including air filter, condensate drain line, blower motor assembly, electrical wiring, and all electrical components with normal findings. Verified proper temperature split across evaporator coil within manufacturer specifications. Inspected outdoor condensing unit including condenser coil cleanliness, capacitor condition, and all electrical connections. Measured and recorded amperage draw on condenser fan motor, compressor, and contactor with all readings within normal operating parameters. Verified refrigerant charge levels appropriate for ambient temperature of 74 degrees. All system components tested and found operating within normal specifications with no deficiencies noted at time of service completion.
Installed customer-supplied Ecobee smart thermostat, configured WiFi connectivity, and verified proper operation through the mobile application. Performed outdoor condenser coil cleaning and replaced failed capacitor to restore system functionality. Completed Xcel Energy rebate documentation for the thermostat installation and confirmed the air conditioning system is operating within normal parameters.
Responded to a water leak under the kitchen sink and successfully replaced a faulty angle stop valve and supply line. The old angle stop was leaking and causing water damage, so new components were installed to restore proper function and prevent further leakage.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.