Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in August 2026.
The most recent job was on August 13, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Responded to master bathroom toilet experiencing weak flushing performance after multiple unsuccessful repair attempts by other contractors. Attempted to diagnose and adjust existing Toto flush valve canister but determined adjustment would not resolve the issue. Removed failed flush valve canister and installed replacement unit provided by homeowner, which restored proper flushing function and met performance expectations.
Responded to callback on recently installed Unico AC system with cooling complaints and thermostat temperature reading issues. Upon inspection, discovered system was short-cycling with condenser shutting off due to low pressure cutout. Diagnosed metering device freezing up at evaporator coil. Root cause identified as mismatched TXV—existing unit equipped with 3-ton valve while condenser and Unico air handler are both 4-ton capacity, causing improper refrigerant metering and system failure. Recommended replacement with properly sized 4-ton TXV kit to match system tonnage and restore proper operation.
Completed comprehensive AC tune-up on 4-year-old Lennox system. Performed standard maintenance protocol including inspection of indoor furnace unit and outdoor condenser, verified proper operation of all components, checked refrigerant levels, and confirmed system functionality. System operating within normal parameters; customer noted second floor could be cooler, which may require future airflow balancing assessment.
Responded to service call for gas line capping at outdoor BBQ location. Successfully capped abandoned gas line extending from ground-level access point, securing the line to prevent gas leakage and ensuring compliance with safety standards. The existing metal housing showed significant corrosion and weathering, with the gas pipe assembly requiring proper termination and sealing to eliminate potential hazards from the decommissioned BBQ connection.
Performed assessment of steam boiler system in 1926 home and evaluated non-functioning radiator valves throughout the property. Provided estimate for replacement of seven radiator valves total—five on the upper level and two on the main level—which are no longer adjustable. Scope of work includes draining the entire heating system, removing and replacing all faulty valves, refilling the system, and bleeding all radiators to ensure proper operation. Additionally provided estimate for required boiler component repairs.
Completed comprehensive plumbing inspection of all fixtures, drains, and water supply lines throughout the property with no deficiencies identified. Performed preventive maintenance flush on water heater (manufactured 10/2017, model MA211760789) to remove sediment buildup and ensure optimal performance. All plumbing systems operating within normal parameters at time of inspection.
Technicians accessed the drain line through the clean out access point located in the closet and cabled the entire length of the line, successfully removing a large hair ball obstruction. A second cabling pass was performed while running water at the sink drain to ensure complete clearance and proper flow. Final testing confirmed the drain system was operating correctly with no leaks detected.
Completed annual cooling maintenance and tune-up on aging air conditioning system as part of Family Rewards membership service. Unit is operational but showing reduced efficiency due to age; all components functioning within acceptable parameters at time of inspection. Recommended monitoring system performance and considering replacement in near future given equipment age and declining efficiency.
Responded to a toilet leak originating from the tank area. Upon inspection, identified two primary issues causing the water leak: a malfunctioning flush valve and a deteriorated tank-to-bowl gasket. Removed the old gasket and replaced it with a new seal to prevent water seepage between the tank and bowl connection. Installed a new flush valve assembly to restore proper flushing operation and eliminate internal leakage. Tested the toilet after repairs to confirm proper fill cycle, flush function, and verify all leaks were resolved.
Completed scheduled Family Rewards cooling maintenance visit on Trane air conditioning system. Performed comprehensive A/C tune-up including system inspection, operational testing, and preventive maintenance procedures. Unit operating within normal parameters with no deficiencies identified or repairs required.
Completed biannual plumbing inspection with focus on water heater and overall system assessment. Inspected under-sink plumbing assembly, noting P-trap configuration with chrome-plated pipes showing age-appropriate wear and minor corrosion at connection points. Observed copper oxidation and verdigris formation at joints, typical of older installations but not requiring immediate intervention. Verified drain assembly and flexible supply lines remain functional. Coordinated HVAC system inspection during same visit, examining copper refrigerant line connections and service valves. All components operating within normal parameters with no new issues identified. Annual inspection confirmed system integrity maintained through proper homeowner care.
Completed annual cooling system tune-up on residential air conditioning unit. Cleaned condenser coil which was found dirty with accumulated debris, inspected electrical components including dual run capacitor and control board, and noted dirty air filter that customer will replace. All system components including wiring, connections, and mechanical elements were inspected and unit is operating properly.
Completed annual cooling maintenance on residential air conditioning system. Performed comprehensive inspection including thermostat operation, filter condition, blower assembly, outdoor coil, electrical components, contactor, capacitor, and condensate drain. Verified refrigerant performance and temperature split across evaporator coils. Changed air filters and confirmed all readings within normal operating range. System operating properly with no mechanical defects or safety concerns identified at time of service.
Completed annual cooling system preventive maintenance inspection on single air conditioning unit. Upon inspection, identified plugged outdoor condenser coil restricting airflow and weak capacitor affecting system performance. Thoroughly cleaned outdoor coil to restore proper heat transfer efficiency. Replaced faulty capacitor and installed hard start kit to improve compressor starting reliability and extend equipment lifespan. System tested and operating within normal parameters following repairs.
Responded to no cooling complaint on 12-year-old first-floor air conditioning unit. Diagnosed and replaced failed capacitor, verified refrigerant levels were within acceptable range, and restored system to normal cooling operation.
Completed annual cooling maintenance visit on residential air conditioning system. Upon inspection, discovered heavily plugged air filter and evaporator coil restricting airflow. Replaced dirty filter with new unit and performed thorough coil cleaning to restore proper system operation. Verified outdoor condenser unit operation and checked for presence of air exchanger as requested. System now operating at optimal efficiency with improved airflow and cooling capacity.
Responded to service call regarding intermittent odor emanating from toilet. Upon arrival, no odor was detected during inspection. Conducted thorough examination of toilet bowl, tank components, and flush mechanism. Inspected TOTO toilet including flapper valve, fill valve assembly, and wax ring seal for potential issues. Advised customer to treat with vinegar and baking soda solution as initial remedy to address potential biofilm buildup in trap or drain line. Provided option for complete toilet removal and jet cleaning of drain line if odor persists.
Completed annual cooling maintenance on one AC system and one dehumidifier per preventative maintenance agreement. Inspected and verified proper operation of condensation pump, air filter, and blower motor on indoor unit. Removed wasp nest from outdoor condenser unit and thoroughly rinsed condenser coils. Tested capacitor, contactor, and verified refrigerant charge levels within manufacturer specifications using digital multimeter and temperature diagnostics. All components operating within normal parameters with no deficiencies noted. System cleared for continued operation through remainder of cooling season.
Completed annual cooling maintenance on two air conditioning systems that were relocated over winter, including a Daikin Fit unit and a unitary AC system. Performed comprehensive startup inspections on both units, checking thermostat operation, filter condition, blower assembly, outdoor coils, electrical components, contactors, capacitors, condensate drains, refrigerant performance, and temperature split. Changed and cleaned filters on both systems. Evaluated refrigerant charge levels, noting the Daikin Fit has factory charge and the unitary AC potentially being overcharged. All readings were within normal operating range with no mechanical defects or safety concerns identified. Both systems confirmed operating properly at this time.
Responded to a water leak at an exterior hose bib that had been previously repaired. Upon inspection, identified that the packing nut had loosened, causing the leak at the valve stem. Tightened the packing nut to proper torque specifications, which resolved the leak and restored full functionality to the outdoor spigot.
©2026 Hurlburt. All Rights Reserved.