Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in August 2026.
The most recent job was on August 17, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Responded to callback for toilet leak that had worsened since initial service visit. Upon inspection, discovered the nuts securing the water meter had loosened over time, causing the increased leakage. Tightened all meter mounting nuts to proper torque specifications and verified no further leaks were present at the connection points.
Removed and replaced defective toilet with new Gerber Viper elongated standard height model. Installed customer-supplied handheld bidet sprayer with wall-mount bracket and connected flexible supply line to water source. All connections tested and verified leak-free upon completion.
Responded to service call for gas line shut-off valve replacement. Upon inspection, determined that the requested work could not be completed as planned. Performed visual assessment of existing gas line configuration and documented conditions with photos for customer records.
Performed comprehensive AC tune-up on residential split system. Discovered and removed deceased rodent from unit and replaced heavily soiled electronic air filter. All system components inspected, cleaned, and verified operational per manufacturer specifications.
Responded to no cooling complaint on system previously serviced. Found system low on refrigerant again, indicating active leak in system. Recharged system with refrigerant and added UV dye to aid in leak detection. Due to extreme attic temperature of 115 degrees, scheduled follow-up appointment during cooler morning hours to safely perform thorough leak inspection and locate source of refrigerant loss.
Responded to service call addressing multiple plumbing issues identified during home inspection. Repaired water leak at main supply pipe above meter near basement ceiling using compression fittings on copper piping. Evaluated and serviced basement laundry sink faucet experiencing difficulty with operation, performing necessary adjustments to restore proper function. Inspected upstairs toilet exhibiting instability and rocking motion, assessed mounting and wax ring condition. Documented existing plumbing infrastructure with photographic evidence showing copper supply lines and bathroom fixtures. Work performed in accordance with Minneapolis municipal code requirements for licensed plumbing contractors, with permit coordination initiated for required safety inspections and final approval.
Responded to no cooling complaint on Bryant air conditioning system. Upon arrival, discovered condensate drain line from indoor head unit was completely disconnected, causing water drainage issues. Attempted reconnection but found the plastic fitting was crushed and unable to properly seal water into the vinyl tube. Temporarily pitched condensate line away from house to prevent water damage. Performed annual cooling maintenance visit including system inspection and testing. Connected manifold gauges to outdoor condensing unit to verify refrigerant pressures and system operation. Submitted parts order request for condensate line replacement from indoor head unit. Restored power to system and turned thermostat to cooling mode to verify compressor and fan operation.
Responded to a water leak at the refrigerator supply line. Upon inspection, identified a broken refrigerator water line as the source of the leak. Removed the damaged line and installed a new refrigerator water supply line, restoring proper water flow to the appliance. Provided estimate for future plumbing work involving disconnect and reconnect of fixtures under the kitchen sink.
Responded to a service call for a Toto Washlet model SW3056AT40 with a non-functioning bidet wand. Upon arrival, confirmed that neither the front nor rear wash functions were activating. Performed a hard reset on the heat exchanger unit to restore system functionality. Conducted multiple operational tests of both front and rear wash cycles to verify proper wand engagement and spray functions. After five test cycles, confirmed all features were operating correctly and left the washlet in full service.
Completed no-charge callback to correct shower valve handle orientation. Handle was initially installed facing the shower wall, preventing visibility of hot/cold temperature indicators. Rotated valve handle 180 degrees so red and blue temperature markings now face outward for proper user visibility and operation. Verified proper function of single-handle shower control and confirmed customer satisfaction with corrected placement.
Performed comprehensive maintenance inspection on residential HVAC system including gas furnace, central air conditioning unit, and wall-mounted mini-split system. Verified proper operation of thermostat, inspected air filter condition, and examined blower assembly components. Conducted safety inspection of furnace heat exchanger, flame sensor, hot surface igniter, and control board, confirming all burner assemblies firing correctly with pilot flames present. Evaluated outdoor condensing unit including coil cleanliness, electrical connections, and refrigerant performance with temperature split measurements. Checked condensate drain line for proper flow and cleared any restrictions. All system readings fell within manufacturer specifications with no mechanical defects or safety concerns identified at time of service. Recommended ongoing preventive maintenance including regular filter replacement and coil cleaning to ensure continued optimal performance.
Performed follow-up maintenance inspection on mini-split system to verify and document previous service work completed by another contractor. Conducted comprehensive tune-up including visual inspection of outdoor condenser unit, which showed weathering and dirt accumulation on protective grille and housing consistent with extended outdoor exposure. System diagnosed with low refrigerant charge requiring attention; provided repair estimate for refrigerant recharge service to restore proper operating levels and system efficiency.
Completed annual cooling maintenance on single-zone residential air conditioning system utilizing 410A refrigerant with ambient temperature at 78 degrees. Performed comprehensive inspection of indoor air handler including thermostat operation, air filter condition, condensate drain functionality, blower motor performance, and all electrical wiring and components with all items found within normal operating parameters. Verified proper temperature split across evaporator coil. Conducted thorough inspection of outdoor condensing unit including coil cleanliness, capacitor condition, and electrical connections. Measured and recorded amperage draw on condenser fan motor, compressor, and contactor with all readings within manufacturer specifications. Verified refrigerant charge and system pressures found to be correct. System operating normally with no deficiencies noted at time of service completion.
Responded to callback for recently upgraded thermostat system (S30 to S40 model). Customer reported incorrect blower fan speed settings and rising humidity levels following initial installation. Verified and adjusted fan speed parameters to match originally specified settings, correcting discrepancy that had caused increased humidity readings. Confirmed thermostat displaying 73°F indoor temperature with 66% relative humidity at time of service, and system operating in cooling mode to maintain setpoint.
Completed annual cooling preventative maintenance on one air conditioning system utilizing 410A refrigerant with outside ambient temperature at 81 degrees. Performed comprehensive inspection of indoor air handler including thermostat operation, air filter condition, condensate drain, blower motor, electrical wiring, and all components with satisfactory results. Verified proper temperature split across evaporator coil. Inspected outdoor condensing unit including condenser coil cleanliness, capacitor condition, and measured amperage draw on compressor motor, fan motor, and contactor with all readings within manufacturer specifications. Verified proper refrigerant charge and system pressures. All systems operating normally with no deficiencies noted at time of service completion.
Responded to no cooling complaint on 10+ year old system with 3-degree temperature differential between setpoint and actual room temperature. Performed diagnostic evaluation using digital manifold gauges to assess refrigerant pressures and system performance. Completed full annual cooling maintenance tune-up including system inspection, performance testing, and necessary adjustments. System operational upon service completion with no issues identified requiring immediate repair.
Responded to no cooling call and found system low on refrigerant with capacitor reading 44 microfarads, indicating failure. Upon inspection, discovered severe corrosion and debris accumulation inside capacitor housing with rust throughout electrical connections. Due to unit age and extent of deterioration, recommended full system replacement while providing estimate for capacitor replacement as alternative option.
Completed routine maintenance and tune-up on residential R410A air conditioning system per Family Rewards membership agreement. Performed comprehensive system diagnostics using refrigerant manifold gauges, verified proper refrigerant pressures (108.4 PSIG suction, 255.4 PSIG discharge), checked superheat and subcool values, and inspected outdoor condensing unit. System operating within normal parameters with no issues identified.
Responded to no cooling call on 7-year-old Mitsubishi Electric mini-split system that would not power on. Upon arrival, inspected outdoor heat pump unit and electrical disconnect. Diagnosed blown fuses at disconnect as cause of system failure. Replaced fuses at disconnect, restored power to unit, and verified proper system operation.
Responded to service call for boiler system with frozen and damaged hydronic heating piping. Upon inspection, found severely corroded 1" black iron pipe with perforation and breach in inaccessible location serving baseboard heating loop in rear section of main level. Corrosion and freeze damage resulted from loop being shut off during previous winter season. Provided estimate for repair solution involving isolation of damaged section by installing shut-off ball valves at accessible basement location, abandoning deteriorated black iron piping in place, and running new PEX tubing to supply side of existing baseboard units. Main boiler system confirmed operational and serving remaining radiators throughout property. Documented existing conditions with photographs showing extent of pipe corrosion, perforation damage, and confined crawl space access constraints.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.