Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in September 2026.
The most recent job was on September 6, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Responded to service call for non-operational MSZ-GX09NL mini-split indoor head unit with failed control board. Removed and replaced defective PCB and associated electrical components in the indoor head unit. Verified all wire connections and proper terminations on the heat pump system. Cycled unit through operational modes to confirm proper function, then adjusted vane positions and fan speed settings to manufacturer specifications. System restored to full operation under parts and labor warranty coverage.
Responded to no cooling complaint on 6-year-old system with intermittent compressor operation and inability to reach setpoint temperature. Upon inspection, found outdoor coil severely restricted with cottonwood debris eliminating airflow through condenser. Tested capacitor and confirmed complete failure with zero reading. Indoor air filter also found heavily soiled and requiring replacement. Compressor safety high-pressure switch had tripped due to inadequate heat rejection from blocked condenser coil. Replaced failed capacitor and verified proper electrical values. Homeowner installed new air filter and elected to clean outdoor coil themselves. After capacitor replacement, verified refrigerant charge and delta-T readings within manufacturer specifications. Cycled system through complete cooling cycle with all components operating normally. Unit cooling properly with compressor running continuously and maintaining setpoint temperature.
Responded to service call for inconsistent hot water delivery from electric water heater. Upon inspection, identified improperly configured thermostats with mismatched temperature settings between upper and lower elements. Corrected thermostat settings to manufacturer specifications, ensuring both units operate at consistent temperatures for optimal hot water production. Additionally observed developing leak at outlet piping connection that will require future attention, though heating elements tested functional at time of service.
Performed comprehensive annual boiler tune-up on 6-year-old hydronic heating system experiencing inadequate water heating. Conducted thorough inspection and cleaning of burners, heat exchanger, circulator pump, relay, igniter, and electrical wiring. Verified gas pressures and combustion air supply were within manufacturer specifications. Cycled system through multiple heating cycles, bled all radiators to remove trapped air, and adjusted system water pressure to proper operating level of 18 psi. Confirmed proper ignition sequence, burner operation, and heat distribution throughout the system. All components functioning correctly upon completion with normal heating restored.
Responded to emergency water leak at laundry sink caused by corroded chrome P-trap that had rusted through completely. The existing metal P-trap assembly exhibited extensive corrosion with green patina and mineral buildup, rendering it unable to maintain a proper seal. Upon inspection, discovered the old fitting had failed due to age-related deterioration and could not be realigned to stop the leak. Removed the compromised metal P-trap assembly and installed new white PVC P-trap with slip-joint connections, restoring proper drainage function and eliminating the water leak. Tested the new installation to confirm leak-free operation, allowing full restoration of water usage for laundry and other household needs.
Responded to no cooling call and performed scheduled AC tune-up. Upon inspection, discovered cracked heat exchanger, broken flame sensor, low refrigerant levels, and failed capacitor. Due to the combination of critical safety issues with the heat exchanger, multiple component failures, and the age of the unit making repairs cost-prohibitive, recommended complete system replacement. Documented conditions with diagnostic photos showing equipment deterioration and temperature readings.
Completed comprehensive annual maintenance inspection on furnace and air conditioning system. Verified and tested all major components including thermostat response, heating and cooling operation, blower airflow, electrical connections, safety controls, refrigerant system operation, condensate drainage, and outdoor unit condition. All components found clean, secure, and operating within normal parameters with no defects or performance concerns identified. No repairs, adjustments, or replacement parts required. Advised to maintain regular filter changes.
Responded to complaint of inadequate upstairs cooling and heating in a single-zone system. Found downstairs supply dampers partially closed and primary upstairs return vent obstructed by stored items. Fully opened all supply dampers and cleared blockage from upstairs return grille to restore proper airflow balance throughout the home.
Responded to warranty callback for persistent leak at roof leader and secondary roof leak. Upon inspection through ceiling access panel, discovered failed repair at 6" roof drain leader caused by structural deficiencies including lack of support under 90-degree elbow and severe backpitch condition. Water accumulation in leader created stress fracture at previous repair point. Installed two mission bands to accommodate stress and movement at leak points. Applied pressure testing to roof drain to verify repair integrity. Documented conditions showing water damage to wooden joists and ceiling materials. Repair completed successfully under warranty conditions. Presented options for permanent replacement versus temporary repair solution due to underlying structural and drainage pitch issues.
Completed scheduled heating maintenance on a 23-year-old Lennox 90% efficiency furnace. Performed comprehensive inspection of heat exchanger with satisfactory results. Cleaned burners, flame sensor, and flushed condensation trap and pump. Tested and verified capacitor within acceptable range, confirmed carbon monoxide levels safe, and verified gas pressure at proper specifications. Inspected air filter, blower motor, and blower wheel—all components operating properly. Conducted manometer readings and capacitor load testing as documented. System is winter-ready and operating efficiently, though age of unit requires continued routine maintenance to ensure reliability.
Completed comprehensive furnace tune-up and maintenance inspection on two gas furnace units (one approximately 1 year old, the other 4-5 years old) as part of recurring preventative maintenance agreement. Performed thorough system evaluation including thermostat operation verification, air filter assessment, blower assembly inspection, burner and heat exchanger compartment examination, inducer operation check, ignition system testing, flame sensor inspection, safety control verification, electrical component assessment, and condensate drain evaluation where applicable. Measured and confirmed temperature rise across heat exchangers within manufacturer specifications. All operational readings fell within normal operating parameters with no mechanical deficiencies or safety concerns identified at this time. Both furnace systems verified to be operating properly and efficiently. Recommended ongoing filter maintenance, coil cleaning, and continued adherence to scheduled tune-up intervals to
Responded to no hot water call and found Rheem water heater in lockout displaying code 47 error. Successfully reset water heater and restored hot water service to home. Performed biannual plumbing inspection including draining and testing exterior faucets, leak detection throughout property, water heater maintenance and cleaning, sump pump inspection, and laundry hose examination. Inspected utility sink in basement area, noting significant staining and mineral deposits in basin indicating age and wear. Provided estimate for laundry tub replacement due to condition of existing fixture.
Completed annual fall heating maintenance visit on residential Slant Fin boiler system, air exchanger, and dryer vent cleaning. Performed comprehensive inspection of boiler including all piping, two-zone operation, circulator pump, backflow preventer, pressure relief valve, heat exchanger, burners, system pressure, and combustion analysis—all components found to be functioning within acceptable parameters with no leaks detected. Combustion testing revealed 1 PPM carbon monoxide emission from lower heat exchanger seals beginning to deteriorate, which does not require immediate shutdown but warrants continued monitoring. Reviewed repair and replacement options with customer and scheduled follow-up service advisor consultation to address heat exchanger seal condition.
Responded to no cooling call at unoccupied duplex unit and diagnosed burned out transformer, fuse, and ECM blower motor. Replaced failed transformer and fuse to restore partial system functionality. ECM motor has been ordered and will require follow-up visit for installation to complete repair.
Completed comprehensive biannual plumbing inspection including water heater, water softener, sump pump, laundry hoses, and leak detection throughout the property. Inspected bathroom and kitchen sink fixtures, faucets, and drain assemblies for proper operation and potential leaks. All plumbing systems found to be functioning properly with no immediate repairs required at this time.
Responded to service call at duplex unit where the existing ECM motor had failed. Diagnosed burned out variable speed ECM condenser/blower motor with module and confirmed system was not operational. Removed the defective motor assembly and installed new variable speed ECM motor with integrated module. Tested system operation and verified proper function. Unit returned to full operational status.
Responded to mainline sewer backup affecting basement floor drain and shower, with water flooding present on basement floor. Diagnostic camera inspection revealed combined toilet paper and tree root blockage at approximately 40 feet in the main line. Cabled the drain line to remove all visible tree roots and debris from the blockage point. Performed complete camera inspection of line to 130 feet to verify clearance and identify any additional issues. Inspection revealed pipe bellies at 26-40 feet and 90-96 feet that may require future monitoring. Conducted 15-minute water flow test from each affected drain fixture to confirm proper drainage and verify complete restoration of system function.
Responded to service call for malfunctioning Blanco kitchen faucet with commercial-style spring coil design and pull-down spray head. Supplied and installed manufacturer replacement parts to repair the faucet assembly. Upon installation, discovered the supplied faucet head was defective and non-operational. Performed system testing and inspection of the installation. Cleaned work area upon completion. One-year parts and labor warranty included with this repair.
Completed comprehensive furnace tuneup and inspection on a 2017 Heil 90% efficiency unit at a rental property. Performed thorough maintenance including scrubbing the flame sensor and burners to ensure optimal combustion. Conducted detailed inspection of all critical components including blower motor, inducer motor, control board, and capacitor—all found to be in good working condition. Thoroughly examined heat exchanger for cracks or deterioration with no defects found. Tested and verified CO levels at 6 ppm and gas pressure at 3.20 w.c., both within acceptable operating parameters. System tested successfully and passed all inspection criteria, operating properly with no issues identified.
Completed annual heating maintenance visit on one furnace system. Found clogged air filter restricting airflow, replaced with new filter. Verified thermostat operation displaying 74°F. Performed electrical diagnostics using digital multimeter to test system voltage and amperage readings. All electrical components tested within normal operating parameters.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.