Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in September 2026.
The most recent job was on September 9, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Performed comprehensive boiler tune-up and preventative maintenance inspection as part of scheduled heating system service. Conducted thorough evaluation of thermostat operation, water pressure levels, blower assembly, burner and heat exchanger compartment, inducer motor operation, ignition system components, flame igniter functionality, safety controls, and all electrical components. Tested carbon monoxide levels and measured temperature rise across the system. All operational readings and measurements were within manufacturer specifications and normal operating parameters. No mechanical deficiencies, safety concerns, or system abnormalities were identified during the inspection. System verified to be operating properly and efficiently at time of service completion.
Responded to no cooling call on Daikin mini-split system. Found one indoor head unit not powering on and another head experiencing communication loss with outdoor unit. Performed system reset which restored proper operation and communication to all zones.
Responded to service call for 3-year-old Lennox central air conditioning unit with inadequate cooling performance. Upon arrival, diagnostic testing revealed abnormally high refrigerant pressures. Removed heavily soiled and restrictive air filter, recommended monthly filter replacement schedule to occupant. Adjusted blower motor speeds to proper settings matching system tonnage specifications. Performed thorough cleaning of outdoor condenser coils which were heavily blocked with cottonwood debris. Following coil cleaning, filter removal, and blower speed adjustments, refrigerant pressures returned to normal operating range and system cooling capacity was fully restored to manufacturer specifications.
Completed comprehensive maintenance inspection on Daikin mini split system including all indoor heads and outdoor condenser unit. Inspected and verified all air filters, blower wheels, evaporator coils, and condenser coils were clean with no debris accumulation. Measured temperature differential across system and confirmed operating within manufacturer specifications. Evaluated outdoor unit condition, verified proper airflow through condenser coil and fan operation. Addressed customer concerns regarding recurring organic growth developing on internal components of indoor air handler units despite regular filter maintenance and previous deep cleaning performed in August. Discussed causation factors contributing to mold development in mini split systems, including humidity levels, airflow patterns, and environmental conditions. Evaluated current iWave air purification device installed in system and its potential contribution to dust adhesion on blower components, which may create condi
Performed comprehensive HVAC tune-up and system inspection on Ruud gas furnace unit. Conducted thorough equipment check-up including pressure diagnostics using digital manometer, with readings of 349 and 355 recorded for system performance verification. Inspected all major components including ductwork, copper refrigerant lines, air handler assembly, and gas connections. All equipment found to be operating within normal parameters with no issues identified or repairs required.
Disconnected and drained electric boiler system in preparation for HVAC installation and concrete cutting work. Shut down boiler, labeled all piping connections, and systematically disconnected water lines using SharkBite fittings to maintain assembly integrity. Removed boiler unit from wall mounting and relocated to floor area near furnace to clear workspace for structural modifications. Entire assembly was removed as a single piece to preserve system components for potential reinstallation or disposal.
Replaced defective variable speed ECM blower motor with module on residential HVAC system. Motor was sourced from shop inventory and installation completed in approximately 2 hours. Verified proper wiring connections at control board, tested system operation, and confirmed motor functionality across all speed settings.
Responded to no-cool complaint on 20+ year old Lennox air conditioning system with water leak at furnace base. Found evaporator condensate drain line completely blocked at drain pan, causing water accumulation. Successfully cleared blockage and verified proper drainage pathway to floor drain. Performed comprehensive system evaluation and discovered inadequate temperature drop across evaporator coil at approximately 12 degrees, indicating cooling deficiency. Upon attempting refrigerant pressure diagnostics, discovered active refrigerant leak at service port Schrader valve with R22 refrigerant escaping, confirming low charge condition. Explained that R22 refrigerant has been phased out and refrigerant-side repairs are no longer performed on legacy systems. Discussed system replacement options and available consultation services for equipment upgrade planning. Customer requested time to consider recommendations. Photos documented existing HVAC equipment configuration and electrical infras
Responded to no cooling complaint on 20+ year old Skymark magic pack system. Upon arrival, found unit running with no blower operation and no airflow through vents. Diagnostic testing revealed system was significantly low on refrigerant charge, resulting in frozen evaporator coil that blocked airflow. Used refrigerant manifold gauges to confirm low charge and identify leak in the system, likely located at the evaporator coil. System operates on obsolete R22 refrigerant. Further inspection of heat exchanger revealed visible rust deterioration with areas rusted through and potential cracks, creating safety concerns. Due to age of equipment, obsolete refrigerant type, refrigerant leak requiring coil replacement, and compromised heat exchanger integrity, recommended full system replacement rather than repair. Scheduled estimate appointment for new magic pack system installation.
Completed comprehensive annual maintenance agreement including spring cooling system tune-up on one standard air conditioning unit and fall heating system tune-up on one AIRE-FLO furnace, one humidifier, and one gas fireplace. All equipment inspected, tested, and found operating within manufacturer specifications with no deficiencies noted or repairs required.
Responded to no cooling complaint on first floor system in 2019-built home where temperature would not drop below 80 degrees. Diagnosed failed dual run capacitor reading 0/5 MFD on a rated 45/5 MFD unit. Replaced capacitor with new unit, restoring proper compressor and condenser fan motor operation. Cleaned evaporator and condenser coils to ensure optimal heat transfer. Verified proper cooling operation from indoor air handler across all zones. Inspected condensate safety switch for proper function. System restored to full cooling capacity and operating within normal parameters.
Responded to a broken baseboard heating line in the rear of the property. Drained down the hydronic heating system and accessed the damaged piping by cutting into the main level flooring near the existing radiator. Rerouted the supply piping using PEX tubing and installed ball valves for future serviceability. Replaced the radiator valve and made new connections to restore flow. During the repair, discovered the return piping would not separate as planned due to seized fittings. System was left in a drained and de-energized state pending return visit with replacement fittings to complete the return line connection. Restoration work for flooring repair will require separate contractor. A permit may be required for this repiping work.
Responded to service call for a 25-year-old Bradford White water heater (Model M140S5BN, 40-gallon capacity, 40,000 BTU natural gas) that had ceased heating water with visible water accumulation in the drain pan. Performed diagnostic inspection of the unit, documented existing conditions through photography of internal components showing heat discoloration and age-related wear, and reviewed manufacturer specifications. Provided estimate for water heater replacement due to unit failure and active leaking at base.
Responded to no hot water complaint on natural gas tanked water heater with pilot ignition failure. Diagnosed pilot assembly and confirmed unit operational after service. Provided customer with repair estimate for future consideration.
Completed annual furnace tune-up and maintenance inspection. Found and replaced dirty air filter. Identified failing humidifier cylinder and discussed replacement options with homeowner.
Completed comprehensive 8-12 point tune-up on both air conditioning and furnace systems under preventative maintenance agreement. Performed full furnace inspection and combustion analysis using Testo 310 II flue gas analyzer, confirming all readings within safe operating parameters and verifying system cleanliness. Documented system performance with diagnostic measurements and enrolled customer in family rewards program for ongoing service benefits.
Completed comprehensive plumbing inspection of residential system, including flushing of A.O. Smith ProLine water heater to remove sediment buildup and ensure optimal performance. Inspected all visible plumbing components, connections, copper and PVC piping, pressure relief valve, and water heater controls. All systems found to be operating properly with no leaks, corrosion, or deficiencies identified at time of inspection.
Responded to a malfunctioning TOTO Nexus one-piece toilet where the flush valve tower was sticking during operation, requiring manual intervention to refill the tank after each flush. Diagnosed the issue as a faulty flush valve mechanism where the green cylindrical component was not engaging automatically. Replaced the complete flush valve tower assembly with OEM TOTO replacement parts (THU747-A and THU407) to restore proper functionality. Following installation, refilled the tank and conducted 5-10 test flushes to verify proper operation and ensure the mechanism engaged correctly without sticking. All components functioned as designed with no issues detected during testing, and the toilet was returned to full service with reliable automatic flush and refill operation.
Performed diagnostic inspection of two outdoor spigots and one top-mount laundry faucet. Both exterior spigots were found to be leaking and require replacement with frost-free faucet assemblies. The indoor laundry faucet was diagnosed as continuously running and in need of replacement. Provided comprehensive quotes for replacing both outdoor faucets with frost-free units and replacing the malfunctioning top-mount laundry faucet. Access work will be required for one of the outdoor spigot replacements, necessitating a hole to be cut for proper installation.
Responded to no cooling complaint on 20+ year old outdoor condensing unit. Diagnosed failed capacitor as cause of system failure. Replaced defective capacitor to restore cooling operation. Advised customer that due to advanced age of equipment, system replacement should be considered in near future to avoid additional repair costs and potential complete system failure.