Since 1959 Hurlburt, we’ve made it our mission to keep your home safe, comfortable and protected.

From freezing pipes in winter to heavy usage throughout the year, your plumbing system in Minneapolis faces unique challenges. Hurlburt provides reliable plumbing services to keep water flowing safely and efficiently throughout your home.
As a trusted plumber in Minneapolis, Hurlburt offers dependable solutions for everything from routine maintenance to complex repairs. Our team handles drain cleaning, pipe repairs, water heater services, and more, all with a commitment to prompt, high-quality service.
Plumbing issues can escalate quickly, especially in colder climates. Our team responds promptly to diagnose and fix problems before they cause serious damage, helping you avoid costly repairs and disruptions.
Modern homes depend on safe, reliable electrical systems. Hurlburt’s licensed electricians in Minneapolis provide a full range of services, from upgrades to repairs, ensuring your home remains powered safely and efficiently.
Our electricians bring the same level of expertise and customer care to every job, ensuring the safety and efficiency of your electrical system. From panel upgrades to lighting installations, we handle every project with attention to detail and a strong focus on safety.
Electrical work should always be handled by professionals. Our team focuses on safety, performance, and long-term reliability with every project, helping homeowners avoid hazards and maintain consistent power throughout their homes.
While winters are known for their intensity, Minneapolis summers can bring heat and humidity that make indoor comfort just as important. Hurlburt offers expert air conditioning services to keep your home cool, efficient, and comfortable all season long.
From quick repairs to full furnace and AC system upgrades, our technicians are ready to handle any cooling challenge. We service both central air and ductless systems with precision and care.
Winters in Minneapolis are not just cold, they are relentless. Hurlburt provides complete heating services including repairs, maintenance, installations, and system replacements to ensure your home stays warm when it matters most. We work on furnaces, boilers, and ductless heating systems, so no matter what setup you have, we can help.
When your heat stops working during a Minnesota winter, it becomes an urgent issue. Our team offers fast, reliable service, including emergency heating repairs, to restore comfort quickly.
For top-quality furnace repair, AC repair, indoor air quality, plumbing, or electrical services in Minneapolis, reach out to Hurlburt and schedule your service today.
Hurlburt Heating & Plumbing has completed 20 jobs in Minneapolis, MN in September 2026.
The most recent job was on September 14, 2026.
Hurlburt Heating & Plumbing has completed 1,695 jobs in Minneapolis, MN in the last 12 months. The first job there was in October 2024.
Completed comprehensive furnace tune-up on Lennox heating system including cleaning flame sensor, inspecting air filter, and verifying proper amperage draw on inducer motor and ECM motor. Measured carbon monoxide levels with satisfactory PPM readings and confirmed temperature rise at 42 degrees. System operating and heating properly. Heat exchanger inspection could not be completed due to camera equipment connectivity issues.
Restored full operation to Toto Neorest toilet in primary bathroom by replacing manufacturer-supplied components including wand assembly, multifunction unit, and deodorizer. Tested all functions post-installation to verify proper operation of bidet features, flush mechanisms, and deodorizing system. Upon inspection of secondary hallway bathroom Neorest unit, identified wand retraction malfunction and coordinated with Toto for replacement parts to restore that unit to proper working condition. Primary bathroom Neorest left in full service with all functions operating normally. One-year parts and labor warranty included on completed repair.
Responded to water leak in basement. Upon arrival, identified active plumbing leak with water still on for the house. Investigated lavatory drain system and determined slow drainage was creating back pressure causing tub overflow. Assessed basement plumbing configuration including water treatment system and vertical pipe assembly. Documented existing conditions with photographs showing utility area layout, sink connections, and mechanical systems. Provided estimate for drain cleaning service to resolve slow drainage issue and prevent future overflow problems.
Responded to callback for low water pressure issues in kitchen and shower following recent water heater replacement. Diagnosed calcium buildup and sediment that had broken free from old water heater and lodged in fixture aerators and valve cartridges, restricting flow throughout the system. Replaced kitchen faucet with new unit to restore proper water pressure and functionality. Replaced bathroom shower valve assembly to eliminate restricted flow in the shower. Tested all fixtures after installation to verify adequate water pressure and proper operation throughout the affected areas.
Responded to service call for Ove brand smart toilet producing constant loud motor noise regardless of power state. Diagnosed malfunctioning electronic control board in bidet seat assembly as source of noise, which ceased only when water supply was shut off. Provided customer with technical assessment and prepared estimate for replacement and installation of new electronic control board components.
Responded to service call for malfunctioning toilet with failed internal flushing components. Removed tank lid to assess condition and found deteriorated fill valve, worn flapper, broken handle assembly, and compromised supply line requiring replacement. Completed full flush mechanism rebuild by installing new fill valve assembly, flapper valve, tank handle, and water supply line. Tested system operation to ensure proper fill cycle, flush function, and verify no leaks at connections.
Responded to no cooling complaint on Daikin 4-ton mini split system displaying E7 error code indicating DC fan motor fault. Upon arrival, verified outdoor unit fan spun freely and investigated further. Accessed control panel and found error code 3-4 with red indicator light, which diagnostics confirmed as refrigerant shortage. Connected manifold gauges to system and recorded suction pressure at 26 PSI with saturation temperature of -16°F, indicating complete loss of R410A refrigerant charge. Informed customer that system requires leak detection service, refrigerant recharge, and UV dye injection to identify leak source. Provided estimate for diagnostic leak search and repair process. System left in non-operational state pending approval and follow-up appointment to locate and repair refrigerant leak before recharging system.
Completed seasonal heating maintenance on two furnaces and two boilers as part of recurring maintenance agreement. Inspected and verified proper operation of all furnace components including filters, temperature splits, burners, flame sensors, igniters, motors, capacitors, drains, and heat exchangers. Performed comprehensive boiler inspections including burners, pilot/spark assemblies, motors, operating temperatures, water levels, expansion tanks, and heat exchangers. All heating equipment found operating within normal parameters. Investigated reported knocking noise from bedroom area during boiler operation but unable to replicate issue at time of visit. Recommended recording noise occurrence for future diagnosis if problem persists.
Responded to service call for leaking toilet approximately 20 years old. Upon inspection, identified faulty fill valve as source of leak. Provided quote for fill valve replacement to resolve the issue.
Responded to service call for a Clorox toilet bowl cleaner pad accidentally flushed down the toilet. Performed diagnostic inspection by scoping the toilet drain completely through to the sewer liner. Unable to locate the cleaner pad in the toilet trap or drain line, indicating the item likely passed through to the mainline without causing obstruction. Completed comprehensive plumbing inspection of the residence. Flushed the water heater to remove sediment buildup and ensure optimal performance. Removed a hair clog from the bathtub drain to restore proper drainage. Verified all plumbing fixtures and systems were operating correctly with no additional issues identified at time of service completion.
Responded to reported water leak in downstairs closet of multi-unit residential property. Upon arrival, inspected affected area and found no active water present. Accessed ceiling cavity via ladder and removed access panel to examine upstairs kitchen plumbing lines serving upper apartment unit. Conducted leak testing on all accessible piping and fixtures in upstairs kitchen with no leaks detected. Inspection revealed evidence of previous water damage to ceiling materials from prior repair work, but no current moisture or active dripping observed. Tenant reported leak occurs only during rainfall, suggesting potential roof or exterior water intrusion rather than plumbing system failure. Documented conditions with photographs showing ceiling access point, exposed framing, and water-stained materials. Additionally performed inspection of downstairs toilet per request and provided replacement proposal using owner-supplied fixture. No immediate plumbing repairs required at this time; recomme
Completed annual heating maintenance visit as part of preventive maintenance agreement, servicing one NTI 150 MBH boiler and one GFP unit. Performed comprehensive system inspection and tune-up with no issues identified. Verified operation of Honeywell V8043E Series 2-Way Zone Valve, which had been flagged during spring maintenance for potential replacement but functioned properly during this visit.
Completed annual heating inspection on residential boiler system as requested prior to property move. Performed comprehensive Pennsylvania heating visit including visual inspection of boiler, associated piping, pressure gauges, valves, and safety controls. Documented additional heating equipment on-site including water heater. All components found operating within normal parameters with no maintenance issues identified at time of inspection.
Responded to a low water pressure complaint affecting a bathroom sink with ROHL fixtures and chrome-plated faucet. Upon inspection, diagnosed the issue as a clogged aerator restricting water flow through the faucet spout. Ordered an aerator key tool to properly remove and service the aerator assembly for this fixture.
Completed city-required HVAC inspection and furnace tune-up. During diagnostic testing, discovered the hot surface ignitor and flame sensor registering elevated ohm readings beyond optimal specifications. Performed thorough inspection using camera equipment to assess internal duct and combustion chamber conditions. Provided detailed estimates for recommended component replacements to ensure continued safe and efficient furnace operation.
Responded to no cooling complaint on 4-year-old Lennox air conditioning system with condenser tripping breaker immediately upon startup. Diagnosed melted wiring harness causing repeated breaker trips. Performed compressor winding resistance testing using digital multimeter, confirming all windings intact and operational. Identified pitted compressor terminal that would prevent proper long-term connection with standard OEM wiring harness replacement. Recommended terminal repair kit installation in conjunction with new wiring harness to ensure secure electrical connections and prevent future failure. Submitted parts request for customer estimate.
Completed comprehensive furnace and boiler tune-up on 2015 furnace and 2017 boiler system at newly acquired property with no existing maintenance records. Performed full inspection including combustion analysis with readings confirming safe operating range, verified heat exchanger integrity, cleaned flame sensor, checked gas pressure and boiler operating pressures, removed debris, and inspected blower and fan motors. Furnace filter was found in serviceable condition. Identified active water leakage at boiler radiator valve and nonresponsive boiler pressure gauge during makeup water addition testing. Completed part request forms for replacement of leaking radiator valve and defective pressure gauge pending approval.
Responded to warranty call for system randomly switching from cooling to heating mode with hot air discharging from vents despite thermostat set to cool. Upon inspection, confirmed furnace was activating heating cycle during cooling calls and when system was off, with control board displaying "H" during malfunction episodes. Performed thorough diagnostic evaluation of thermostat settings, verified proper configuration, and inspected all associated wiring for damage or loose connections—no wiring issues identified. Determined faulty control board as root cause of erratic heating activation. Ordered replacement control board under warranty coverage. Equipment photographed for documentation. Will return upon parts arrival to complete installation and verify proper system operation.
Performed municipal rental license inspection on 30-year-old furnace system. Upon thorough examination using borescope camera equipment, discovered cracked heat exchanger posing immediate safety hazard. Shut off gas supply to unit, red-tagged furnace as unsafe for operation, and documented findings with photographic evidence of heat exchanger damage.
Completed annual furnace inspection on 30+ year old Utica boiler system. Performed comprehensive evaluation including piping integrity, venting condition, backflow preventer, pressure relief valve, system pressure levels, burner cleanliness, and expansion tank operation. Conducted combustion analysis and carbon monoxide testing at heat exchanger seals with satisfactory results. Verified all radiators heating properly throughout system. Inspection camera revealed significant corrosion on cast iron heat exchanger, particularly severe on right side of unit. Corrosion presents potential safety hazard as deteriorating sections could detach and fall onto burner assembly during operation. Documented findings with thermal imaging and interior inspection photographs showing mineral deposits and metal deterioration on ribbed heat exchanger surfaces. All other system components including gas valve, copper connections, and piping connections found in acceptable working condition with normal wear
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.