Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Responded to insufficient cooling complaint and found A/C unit low on R22 refrigerant with indoor fan not operating. Upon inspection, determined system is approximately 30 years old and has reached end of serviceable life. Recommended complete equipment replacement due to age, obsolete refrigerant type, and multiple component failures.
Responded to no-cooling complaint on 10-year-old Lennox central air system experiencing evaporator coil icing. Performed comprehensive diagnostic including airflow verification, air filter inspection (found clean), and outdoor condenser coil evaluation and rinse-down. Connected manifold gauges to refrigerant system and identified low refrigerant charge as primary cause of cooling failure and ice formation. Discussed repair options including system recharge versus full system replacement given age of equipment. Customer declined immediate repairs and requested consultation with service advisor for new system pricing. Advised customer on temporary operation limitations until replacement decision is made.
Responded to complaint of unit running constantly without adequate cooling on 1-year-old Lennox system. Upon inspection, determined indoor blower was operating continuously. Identified thermostat fan switch had been inadvertently set to "ON" position instead of "AUTO" mode. Adjusted Honeywell Home ProSeries thermostat fan setting from continuous operation to AUTO mode, which resolved the issue immediately. Verified system now cycles properly with blower activating only during heating and cooling calls. Provided customer education on proper thermostat operation and function of fan control settings to prevent future occurrences. No mechanical defects found; unit operating within normal parameters.
Responded to callback for Steffes heat pump unit with non-functioning control board. Upon rediagnosis, identified that previously installed outdoor sensor was incorrectly connected to thermostat via Wi-Fi/Bluetooth instead of being hardwired directly to the unit's control board. Determined that correct hardwired sensor must be obtained and installed to the Steffes control board before further diagnostics can proceed. Recommended reinstalling original control board to unit. Documented equipment condition with photos for reference.
Responded to report of high-severity water leak with unknown source initially suspected to be from water heater or furnace. Upon investigation, determined leak originated in laundry room from HVAC mini giant pump discharge hose that had come out of standpipe. Leak was already addressed prior to arrival. Proceeded with scheduled replacement and installation of new iron filter as requested. Unit installed and operational.
Responded to callback for AC unit installed 13 days prior with reported basement flooding from condensate drainage issue. Upon arrival, found significant water accumulation near furnace area with floor drain backing up and unable to handle discharge volume. Documented conditions with photos showing extensive water pooling on basement floor and compromised drainage system. Diagnosed clogged floor drain as primary cause preventing proper condensate removal. Scheduled plumber to snake drain line and advised that condensate pump installation with upstairs drain routing would be required if drain clearing unsuccessful.
Responded to service call for mini split system with inadequate airflow in office area. Upon inspection, found both indoor air handler units operational but producing minimal airflow despite blower motors running. Diagnosed severely clogged blower wheels restricting air circulation in both heads. Provided updated estimate for complete blower wheel cleaning service, which was approved. System currently maintaining cooling function but operating at reduced capacity. Scheduled follow-up appointment to perform thorough cleaning of blower wheels and evaporator coils using appropriate cleaning solutions and containment equipment to restore proper airflow and system performance.
Responded to service call for furnace blower motor not operating and water dripping inside unit. Upon arrival, activated system and confirmed blower motor engaged properly. Connected manifold gauges and identified low refrigerant pressures on 31-year-old R-22 system. Conducted airflow verification and inspected filter, blower wheel, and evaporator coil for obstructions. Found minimal dust accumulation on blower wheel insufficient to cause pressure drop. Observed top half of evaporator coil not sweating, indicating partial freezing condition. Determined system is undercharged on R-22 refrigerant, causing evaporator to ice over and restrict airflow, which led to perceived blower failure. Documented extensive corrosion on unit base plate, electrical connections, and copper refrigerant lines with significant rust and oxidation present throughout equipment. Photographed deteriorated conditions showing moisture damage and age-related wear on metal components and housing. Reviewed findings in
Responded to service call for constantly running toilet and leaking outdoor hose bib. Diagnosed faulty flapper as cause of toilet issue. Addressed primary concern of exterior hose bib that continued leaking and running water after shut off. Removed defective hose bib and installed new replacement unit. Tested new hose bib for proper operation and verified no leaks upon shut off. Completed copper pipe connection work in crawl space area to ensure proper water flow and eliminate leakage issues.
Responded to no cooling complaint on 3-year-old HVAC system experiencing reduced airflow and inability to maintain temperature. Upon inspection, discovered excessive condensation and moisture accumulation in furnace cabinet caused by humidifier bypass damper left open in summer mode. Cold supply air mixing with warm, humid outside air through open damper created condensation on ductwork and components, resulting in visible rust on metal pipes and moisture throughout electrical compartment. Verified system producing proper 20-degree temperature split, confirming cooling function operational. Closed humidifier bypass damper to winter position to prevent continued moisture infiltration. Instructed homeowner on proper seasonal damper operation and recommended removing top access door temporarily to allow trapped moisture to evaporate and cabinet to dry completely, preventing further corrosion of components.
Completed follow-up visit on recent HVAC installation. Installed new RDS sensor on coil to replace defective unit. Upon arrival, discovered customer was expecting furnace tune-up and repair of leaking collector box based on previous communication with installation team. Performed inspection of collector box and identified active leak requiring replacement. Captured photographs of equipment model and serial number information and forwarded to parts department for replacement collector box quote.
Responded to a leaking shower complaint and diagnosed a faulty cartridge as the source of the leak. Removed the defective cartridge and installed a replacement unit, restoring proper function to the shower system. The dual showerhead fixture now operates without leakage.
Responded to warranty call for AC system installed in May 2026 not maintaining temperature during high ambient conditions. Performed comprehensive system evaluation including visual inspection of attic-mounted equipment and ductwork. Measured and documented temperature differentials and system performance parameters using calibrated digital instruments. Observed installation conditions and equipment placement in unconditioned space with surrounding fiberglass insulation. Assessed mechanical components, refrigerant lines with foil-wrapped insulation, electrical connections, and supporting infrastructure in crawl space area. Documented findings with detailed photographs of equipment location, structural mounting, and overall installation quality. Completed follow-up form for installation team review to address performance concerns and ensure system meets design specifications for proper cooling capacity in current weather conditions.
Replaced control board on heat pump air handler due to system malfunction. After installation, discovered the new board exhibited the same issue as the original, failing to send 24V signal to the outdoor condensing unit. Implemented temporary solution by directly wiring the outdoor unit's thermostat wiring to the thermostat terminals on the control board, restoring cooling operation while both boards remain installed pending further diagnosis.
Completed annual air conditioning tuneup on 11-year-old Lennox outdoor condensing unit. Performed comprehensive system inspection and testing with all electrical components measuring within manufacturer specifications. Cleaned and washed outdoor unit coil and cabinet to ensure optimal airflow and heat transfer. Unit operating properly with no deficiencies noted at time of service.
Replaced IBC indirect water heater tank under manufacturer parts warranty, including complete removal and disposal of failed unit. During system restoration, the backflow preventer began leaking upon water supply activation, requiring immediate replacement with new brass backflow prevention device. Installed new indirect water heater with expansion tank, connected all copper piping, and verified proper integration with existing IBC boiler system. Purged air from hydronic heating system, tested all heating zones for proper operation, and confirmed system pressure stabilized at 22 PSI. All components functioning within normal parameters upon completion.
Completed comprehensive AC tune-up on Lennox system. Identified and resolved condensate drainage issue caused by pinched hose at furnace corner—repositioned hose to eliminate restriction and restore proper drainage flow. Performed outdoor unit cleaning, conducted electrical testing with all readings within manufacturer specifications, and verified system performance with 20-degree temperature split across coil.
Completed comprehensive AC tune-up maintenance agreement including filter replacement, blower inspection, and evaporator coil evaluation which was found clean and draining properly. Performed routine electrical component inspection on outdoor unit, cleaned condenser coils, and conducted operational testing with 15-minute run cycle confirming proper system performance with 17-18 degree temperature differential. Addressed customer concerns regarding window condensation, explaining that current high humidity levels make condensation difficult to avoid, and confirmed all equipment operating within normal parameters.
Responded to a bathroom plumbing emergency where both the bathtub and toilets were not draining properly. Upon arrival, confirmed that the tub had stopped draining mid-shower and multiple fixtures in the bathroom were experiencing severe drainage issues. The homeowner had previously attempted to clear the blockage using a chemical drain cleaner (Green Goblin), which provided minimal temporary relief but did not resolve the underlying obstruction. Assessed the situation and determined that the clog was affecting multiple fixtures simultaneously, indicating a main drain line blockage beyond the scope of standard drain cleaning methods. Due to the severity and location of the blockage in the drainage system, the job required specialized equipment and techniques beyond what was available on-site. Documented the condition of the affected fixtures with photographs and referred the customer to a specialist drain cleaning service (Roto-Rooter) equipped with professional-grade augering and
Responded to water leak in south utility room identified in home inspection report. Replaced leaking valve behind structural beam and installed proper discharge piping for water heater temperature and pressure relief valve, which was previously missing and posed a safety hazard.