Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Responded to no-cool complaint on Goodman GSX130241FA condenser (approximately 5 years old, installed 2021-2022, single-phase R-410A system). Found outdoor unit repeatedly blowing 30-amp Edison fuses at disconnect; homeowner had previously replaced capacitor and installed hard start kit with no improvement. Diagnosed one compressor terminal leg electrically grounded to case, with active refrigerant leak detected at same terminal. Confirmed compressor failure requiring replacement and initiated warranty verification due to unit age.
Responded to reported water leak in master shower dripping into basement mechanical room. Upon arrival, area had been dried and no active leak was visible. Conducted diagnostic testing by running shower for 20 minutes to attempt replication of leak condition. No dripping or moisture detected during test period. Removed escutcheon plate and shower valve handle to inspect behind wall assembly. All components and surrounding areas were completely dry with no evidence of moisture intrusion or valve failure. Based on findings and information provided, determined likely cause was water dripping from washcloth that had been hanging on shower rack near valve, creating appearance of plumbing leak. Reassembled shower valve components. Advised to monitor after each shower use and contact if leak recurs.
Completed comprehensive preventive maintenance on Lennox furnace and air conditioning system. Cleaned condenser coils, inspected all electrical components and connections, cleaned flame sensor and drain system, blew out pressure switch ports, and verified blower assembly cleanliness. Confirmed air filter in clean condition, drain line clear and flowing properly, temperature rise and temperature drop measurements within manufacturer specifications. All system components tested and operating correctly with no deficiencies noted.
Responded to no cooling complaint on 3-year-old R22 system and found evaporator coil frozen. Identified potential causes as restricted airflow from dirty filter or low refrigerant charge. Arranged follow-up appointment with comfort advisor to assess system condition and discuss repair options.
Completed comprehensive AC tuneup on residential system. Upon arrival, customer reported squeaking sound from AC lines in basement during operation. Performed full system diagnostics and testing, including capacitor testing which revealed out-of-specification readings. Contactor showed pitting but remained functional. Presented findings and recommended replacement of capacitor and contactor to prevent future system failure. Customer declined both repairs at this time. Documented equipment condition with photos showing outdoor unit components, wiring configuration, and electrical measurements. System remains operational but with noted component degradation that may require attention in the near future.
Returned for callback on continuously running toilet that was not resolved during initial visit. Upon inspection, removed old flapper valve which was found to be cracked and causing the constant water flow. Installed new flapper assembly and performed dye test to verify proper seal and confirm issue was fully resolved.
Responded to service call for melting observed on top of 50-gallon natural gas chimney vent water heater. Upon inspection, discovered improper chimney venting installation identified during home inspection. Measured chimney vent and found back pitch of approximately 1 inch over 1-foot span, preventing proper draft. Observed heat damage and melting on trim rings at water heater nipple connections due to inadequate venting. Additionally found flue damper cocked approximately quarter turn out of proper position, further restricting exhaust flow. Disassembled existing chimney vent system and shortened vertical portion to correct improper pitch. Reinstalled chimney vent piping with proper upward pitch to ensure adequate draft. Adjusted and repositioned flue damper to correct alignment. Fired water heater and verified proper draft by confirming heat rising through vertical chimney portion. Confirmed all exhaust gases venting appropriately with no heat buildup at trim rings or top of unit. S
Responded to no cooling complaint on 15-year-old York central air conditioning system with indoor temperature at 78°F. Upon arrival, found evaporator coil completely frozen with severely clogged air filter restricting airflow. Removed plugged filter and left blower running in fan-only mode to thaw frozen coil. Advised homeowner that once coil is fully thawed, system should be restarted to verify proper cooling operation. Informed homeowner that if cooling issues persist after thaw cycle completes, a refrigerant leak or low charge is likely and system replacement should be considered given age of equipment.
Responded to no cooling complaint on 26-year-old central air conditioning system running but unable to maintain temperature. Upon arrival, found evaporator coil frozen solid. Allowed coil to thaw sufficiently to perform diagnostics. Verified adequate airflow across coil once thawed. Performed refrigerant charge check and confirmed system was significantly low on R-22 refrigerant. Inspected outdoor condenser unit and refrigerant lines, noting severe corrosion and rust deterioration on copper piping connections and mounting hardware, indicating age-related degradation and potential leak points. System showing multiple signs of end-of-life failure including refrigerant loss, corroded components, and diminished cooling capacity. Given the age of the equipment, obsolete R-22 refrigerant requirements, extent of corrosion damage, and cost of repairs versus replacement, provided customer with comprehensive pricing options for both refrigerant recharge repair and complete system replacement. Co
Completed installation call back to address AC startup issue and missing components from original install. Replaced two sections of yellow CSST gas line with FlashShield, installed missing 2-1/4" x 12" brown floor register, and troubleshot non-operational air conditioning system. Charged AC system to correct subcooling specifications, restoring full functionality to unit.
Responded to no-cool complaint on 4-year-old residential air conditioning system that was cooling inadequately throughout the home. Performed diagnostic evaluation and determined system was operating with low refrigerant charge. Added R-410A refrigerant to system from available supply and injected UV dye into refrigerant circuit to facilitate future leak detection and monitoring. System returned to operational status following refrigerant charge adjustment.
Responded to callback for persistent loud gurgling noise from reverse osmosis system drain line following previous filter replacement service. Rerouted RO drain line to dishwasher standpipe and installed check valve to eliminate noise and prevent backflow. Tested system operation to verify complete resolution of drainage noise issue.
Responded to service call for mini-split system experiencing inadequate cooling due to excessive dirt accumulation. Performed thorough cleaning of two mini-split indoor unit heads and blower wheels, removing substantial debris that was restricting airflow. Upon completion, system demonstrated significantly improved airflow and rapid cooling performance in affected rooms, restoring unit to proper operating condition.
Replaced undersized residential air conditioning unit with upgraded 2.5-ton Lennox EL15KC1-030 system to address inadequate cooling capacity. Existing coil was evaluated and determined to be compatible with new unit, allowing for retention and cost savings. Removed original equipment, installed new condenser on existing concrete pad, connected refrigerant lines to existing coil, completed electrical connections, and tested system for proper operation and cooling performance.
Responded to no cooling complaint on residential Goodman air conditioning unit. Upon arrival, confirmed system was not operating and outdoor unit was not running. Performed diagnostic testing and identified failed dual run capacitor with no measurable capacitance. Replaced defective capacitor with properly rated replacement part. Cycled system through complete operational test, verified compressor and condenser fan motor startup, confirmed proper amp draw on both components, and validated adequate airflow and cooling performance. Unit restored to normal operation.
Installed customer-supplied garbage disposal with air switch in kitchen with no previous disposal unit. Property operates on well and septic system, which was taken into consideration during installation. Also installed new customer-supplied kitchen faucet to complete the kitchen plumbing upgrade.
Completed routine cooling system maintenance as part of membership agreement for unit less than five years old. Performed comprehensive AC tune-up including washing outdoor condenser coil, inspecting electrical connections and components to verify all readings within manufacturer specifications, and replacing air filter. System operating properly with no issues found.
Responded to service call for reverse osmosis system producing excessive gurgling noise that had progressively worsened since installation. Upon inspection, diagnosed low storage tank pressure as primary cause of the issue. Performed annual maintenance by replacing all RO filters, re-pressurized the storage tank to manufacturer specifications, and installed a new flow regulator to resolve the gurgling condition and restore proper system operation.
Responded to gas leak emergency at dryer location that had been yellow-tagged by utility company. Upon inspection, identified two loose fittings on the gas line supply piping adjacent to the dryer unit. Disassembled the compromised fittings, applied fresh pipe sealant, and properly reassembled and torqued connections to manufacturer specifications. Performed comprehensive leak detection testing using soap solution on all gas line connections and joints to verify system integrity. Confirmed no further leaks present and restored safe operation of gas supply line to appliance.
Responded to a water heater failure with active leaking and no hot water production. Upon inspection, determined the existing tanked water heater was beyond repair and required complete replacement. Successfully removed the failed unit and installed a new tanked water heater with proper connections to existing copper supply lines, pressure relief valve, and electrical service. Verified all plumbing connections for leaks, confirmed proper operation of the new water heater, and ensured the system was functioning correctly with adequate hot water delivery.