Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Completed comprehensive air conditioning tune-up on older Trane outdoor condensing unit and Trane XE 80 furnace system. Performed standard preventive maintenance procedures including inspection of all major components, electrical connections, refrigerant levels, and system operation. Unit found to be in good operating condition with no deficiencies noted or repairs required at this time.
Responded to water leak complaint on 7-year-old furnace. Found condensate drain line and pan completely filled with sludge buildup, restricting proper drainage. Discovered collector box plug had been leaking, causing rust spots on surrounding components. Vacuumed out accumulated sludge and debris from condensate system, removing foreign material including a dead bat from the pan. Flushed drain system with approximately 10 bottles of water to verify proper flow and pump operation. Resealed collector box plug to prevent future leakage. Cleaned condensate pan and drain line thoroughly. System tested and draining properly upon completion.
Responded to clogged toilet caused by foreign object lodged in trapway. Upon inspection, determined that a baby wipe container lid had been accidentally flushed, creating complete blockage. Successfully cleared obstruction using toilet auger, restoring full drainage and proper flush function. Verified toilet operation with multiple test flushes to ensure complete removal of blockage and normal water flow.
Completed comprehensive rooftop unit maintenance on multiple RTUs, replacing various sized filters including 16x25x2, 20x20x2, 18x24x2, and 24x24x2 units. Installed new belts across all units including Ax43, Bx71, Ax46, 3L200, Ax26, Ax21, Bx64, and Bx62 specifications. Performed thorough coil flushing on all rooftop units using approximately 200 feet of garden hose to clean equipment, then ran and tested all systems to verify proper operation.
Performed comprehensive tune-up and maintenance inspection on a 24-year-old Lennox air conditioning system utilizing R22 refrigerant. Completed thorough system evaluation including condenser unit inspection, electrical component testing, and refrigerant charge verification. All components tested within manufacturer specifications and system operating properly at time of service.
Responded to emergency call for flooding in showroom caused by wall-mounted toilet fixture. Upon inspection, identified active leak at flush valve assembly with water dripping from mounting nut. Tightened flush valve nut to stop leak that had been creating puddle on floor throughout the weekend. Verified proper operation of flush mechanism and checked for additional leaks. Photographed completed repair and documented previously installed flush valve assembly from prior service visit.
Responded to no-cooling complaint on 28-year-old residential air conditioning system. Upon arrival, confirmed indoor blower operational but outdoor condenser unit fan not running. Diagnostic testing revealed failed dual-run capacitor preventing compressor and condenser fan operation. Additionally, system found to be low on R22 refrigerant, indicating potential leak in aged system. Replaced defective capacitor to restore immediate cooling function and recharged system with R22 refrigerant to proper operating levels. Due to advanced age of equipment, obsolete refrigerant type, and overall condition showing significant weathering and deterioration, scheduled follow-up consultation with comfort advisor to discuss system replacement options and long-term solutions.
Completed comprehensive tune-up service on both furnace and air conditioning systems for an 8-year-old HVAC installation. Performed electrical testing on both units with all readings confirming operation within manufacturer specifications. Cleaned the outdoor condensing unit, cycled both systems through operational testing, and verified proper performance with temperature differentials measuring 20 degrees on heating and 45 degrees on cooling.
Responded to no-heat call on furnace under 10 years old. Upon arrival, found homeowner had recently replaced thermostat but unit still would not operate properly. Diagnosed ignition system failure where flame would light but would not remain lit. Tested control board and confirmed millivolt signal present, indicating faulty board as root cause of ignition lockout. Provided estimate for replacement control board installation. Homeowner opted to replace entire furnace system instead of proceeding with board replacement. Scheduled complete furnace replacement for following day.
Conducted comprehensive plumbing assessment addressing multiple issues including two deteriorated exterior hose bibs requiring replacement, one with continuous dripping that could not be shut off. Inspected water heater exhibiting leak from overhead piping connections and insufficient recovery rate. Evaluated laundry room drainage problems where washing machine discharge and utility sink were improperly connected, causing water to drain directly onto floor rather than into proper waste lines. Provided estimate for immediate replacement of most severely compromised outdoor faucet and recommended scheduling comprehensive repair of all identified issues in single service visit for optimal efficiency.
Responded to a no-cooling complaint on a Trane S9V2B080U gas furnace with Honeywell T10 thermostat. Performed systematic low-voltage troubleshooting to isolate the failure point. Verified 28 VAC present at R to C terminals on furnace control board, confirming transformer and control power circuit integrity. Measured Y to C during cooling call and found 0 VAC while indoor blower operated normally, indicating no cooling output signal from thermostat. Tested outdoor unit and contactor circuit by jumping R to Y terminals at furnace board, which produced proper 28 VAC at contactor and successfully energized the condenser, confirming outdoor unit, field wiring, and contactor circuit were functional. Identified thermostat was wired using Honeywell wire-saver/K terminal configuration with no direct Y output at subbase. Determined the failure point was thermostat wire-saver control strategy or compatibility issue, not condenser circuit or outdoor unit malfunction. Recommended abandoning wire-
Responded to report of water leaking from air handler unit. Upon inspection, found water leaking from seams of air handler and evaporator drain hose. Discovered evaporator drain line was partially obstructed and flushed to clear blockage. Identified severely clogged air filter creating negative pressure in the system, which was preventing proper condensate drainage by drawing air through the drain line. Removed and replaced dirty air filter, which immediately restored proper drainage function. Advised occupant on importance of monthly air filter replacement to prevent recurrence of drainage issues. System tested and confirmed draining properly after service completion.
Performed preventive maintenance on 5-year-old residential air conditioning system in response to concerns about inadequate cooling below 72°F during hot weather. Conducted comprehensive inspection including condenser coil cleaning, air filter verification, condensate drain line clearing, and electrical component testing. All measurements including temperature differential were within manufacturer specifications, air filter was clean, and all electrical components in condenser unit tested within normal operating parameters with no deficiencies identified.
Responded to a frozen and cracked hose bibb that resulted from improper installation and inadequate drainage. The exterior spigot supply line, approximately 3 feet in length, sustained freeze damage due to incorrect grading that allowed water to remain trapped in the fixture. Removed the damaged hose bibb, installed a new frost-proof hose bibb with proper pitch to ensure complete drainage, and verified the dedicated shut-off valve was functioning correctly to allow for seasonal winterization.
Responded to callback for Lennox AC system not maintaining temperature following recent tune-up. Upon inspection, found heavily soiled and deflected air filter blocking airflow, causing inadequate cooling performance. Educated homeowner on proper maintenance schedule, emphasizing 30-day filter replacement intervals based on home size and system requirements to prevent future performance issues.
Responded to a water leak at the pressure valve assembly located above the pressure tank, which serves both the domestic water supply and boiler system. Upon inspection, identified a leaking Amtrol air vent (15 PSI rated) on the boiler system with visible moisture damage and oxidation on the surrounding components. Confirmed the leak was active and provided an estimate for replacement of the defective Amtrol air vent part to resolve the issue.
Responded to service call for mini split condensate pump replacement in attic location. Upon arrival, removed existing 230V condensate pump and attempted installation of 115V replacement unit. During installation, incorrectly wired new 115V pump with 230V power supply, resulting in incompatible voltage application to unit. Identified voltage mismatch error and ceased operation to prevent equipment damage. Coordinated with parts department to order correct 230V condensate pump replacement. Return visit required to complete proper installation with voltage-matched pump and remove incorrectly specified unit.
Responded to leaking hose bib caused by deteriorated piping. Removed outdated whole home filter system and replaced old supply piping with new lines to accommodate new hose bib installation. Verified proper operation and confirmed no leaks upon completion.
Performed AC tuneup and discovered system operating with only an 11-degree temperature split in cooling mode. Pressure readings indicated the unit was low on R410A refrigerant. Recharged the system with R410A refrigerant and added UV dye to aid in leak detection. Scheduled follow-up visit to locate and address potential refrigerant leak in the system.
Responded to kitchen sink clog caused by vegetable matter accumulation in the drain line. Successfully cleared the blockage using plunging techniques, restoring proper drainage through the garbage disposal system. Additionally, replaced a worn toilet flapper to address secondary plumbing issue identified during the service visit.