Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Completed comprehensive air conditioning tune-up on 2021 unit with no operational issues identified. Cleaned outdoor condenser coil, inspected evaporator coil, and flushed 40 ounces of water through the furnace condensate pump to verify proper drainage. Discovered minor crack in condensate pump housing and advised homeowner that a replacement pump will be sourced to prevent future leakage issues.
Responded to no-cool complaint on 2014 Nordyne R-22 air conditioning system at rental property. Tenant reported severe suction line icing with water intrusion into furnace cabinet. Upon arrival, system had been off approximately 12 hours per previous instruction. Conducted pressure diagnostics revealing equalized standing pressure of 59 psig on both suction and liquid lines with 85°F outdoor ambient temperature, confirming system is substantially undercharged. Visual inspection confirmed previous ice formation on suction line and water damage to furnace area. Pressure readings indicate significant refrigerant leak in sealed refrigerant circuit. Per company policy, no leak search, coil repair, or R-22 recharge was performed on this aging system. Advised property owner that system requires either complete leak repair with refrigerant circuit restoration or full equipment replacement to restore cooling operation.
Completed annual AC and furnace maintenance plan inspection with full system evaluation. AC system operating within manufacturer specifications with proper subcooling levels confirmed. Inspected blower assembly and ductwork components, documenting condition with photos. Addressed comfort concerns in living room area, identifying insufficient supply venting as primary issue rather than equipment malfunction. Scheduled follow-up consultation to discuss ductless mini-split installation as supplemental solution for problem area.
Replaced defective gas regulator on residential Honeywell standby generator under full parts and labor warranty. Installed new regulator, performed leak test on all gas connections, and verified proper gas pressure delivery to unit. All systems tested and operational with no leaks detected. Additionally provided consultation regarding existing boiler system and discussed annual maintenance requirements including system pressurization and water level monitoring.
Responded to water leak complaint with visible ceiling damage in kitchen area directly below master bathroom shower. Upon investigation, determined leak was isolated to shower usage only. Inspection revealed improperly closing shower door allowing water to escape containment area, run down shower curb, and accumulate on tile floor. Water penetration occurred through grout lines and substrate, migrating to ceiling below. Performed exploratory opening in kitchen ceiling to confirm moisture source and verify water damage location corresponded with shower curb position. Documented conditions with photographic evidence showing ceiling water staining and bathroom floor conditions including moisture accumulation near shower door track. Advised property owner that shower door requires adjustment or replacement to establish proper seal and prevent continued water escape. No plumbing system defects identified; issue attributed solely to shower enclosure door malfunction allowing water bypass dur
Responded to emergency call for burst pipe under kitchen sink. Upon inspection, discovered the drinking water filter was leaking and had caused significant water damage, with the sink base cabinet completely rotted out from prolonged moisture exposure. Disconnected the drinking water faucet assembly and installed new shut-off valve on the cold water supply line. Replaced deteriorated supply line to cold side of kitchen faucet and tested all connections. Verified no leaks present after repairs and system restored to full operation.
Completed scheduled preventive maintenance tune-up on residential Lennox furnace system located in basement utility area. Performed comprehensive inspection of heating unit, ductwork connections, and PVC venting system per manufacturer specifications. No issues or deficiencies were identified during inspection, and all system components were found operating within normal parameters.
Responded to leak under kitchen sink caused by deteriorated drain assembly. Upon inspection, found that the existing drain assembly had failed due to age and previous attempted repair by homeowner. Removed old drain assembly and installed new replacement unit. Additionally installed Studor vent to ensure proper drainage system function and prevent future issues. System tested and verified leak-free operation upon completion.
Completed routine cooling maintenance and AC tune-up on 6-year-old Amana HVAC system located in unfinished basement utility area. Performed comprehensive inspection per maintenance agreement protocol, including checking refrigerant levels, cleaning condenser coils, inspecting electrical connections, testing thermostat operation, and verifying proper airflow through ductwork. System operating within normal parameters with no issues identified or repairs required at time of service.
Responded to low water pressure complaint in upstairs bathroom shower. Upon inspection, removed and examined dual shower head system, including rainfall head and handheld unit. Found no debris or blockages in shower heads or supply lines. Determined that factory-installed flow restrictor was limiting water pressure to the fixture. Verified adequate water pressure at shower arm connection, confirming well system and supply plumbing functioning properly. Discussed option to remove flow restrictor with customer, explaining potential risks of debris accumulation without restriction in place. Customer elected to maintain current configuration with flow restrictor installed.
Responded to no cooling complaint on 5-year-old air conditioning system displaying fault code 179 for outdoor unit communication failure. Upon arrival, confirmed outdoor unit was completely inoperative with no low voltage present. Performed diagnostic testing on both indoor and outdoor units to isolate the issue. Testing revealed the outdoor unit's control board/inverter module had failed, preventing proper communication and power distribution to the compressor and fan motor. Removed access panel, disconnected all wiring harnesses from the defective board, and removed the failed component. Installed new outdoor unit control board/inverter, reconnected all electrical connections including low voltage communication wiring and high voltage power leads, and secured the board properly within the housing. Verified all wire terminations were tight and properly seated. Restored power to the system and tested operation. Confirmed outdoor unit now communicates properly with indoor unit, compress
Completed comprehensive AC tune-up on residential cooling system per maintenance agreement. Replaced dirty air filter, verified blower assembly was clean and properly balanced, confirmed evaporator coil was clean with proper condensate drainage, and inspected all electrical connections and components on outdoor unit with readings within manufacturer specifications. Noted outdoor fan motor operating louder than normal during 15-minute runtime test, though system achieved proper temperature split of 18+ degrees and all components functioned as designed; customer declined repair estimate at this time and elected to monitor condition.
Responded to a water leak underneath the kitchen sink caused by a failing basket strainer on the right side basin. The existing basket strainer had been sealed with plumber's putty that had deteriorated and was no longer maintaining a watertight seal. Removed the old basket strainer assembly and installed a new basket strainer, utilizing silicone sealant instead of putty to ensure a durable, leak-proof connection. Tested the repair to confirm proper drainage and verified no additional leaks were present.
Performed routine cooling maintenance on a 26-year-old Amana air conditioning system utilizing R22 refrigerant. During inspection, identified capacitor reading significantly out of manufacturer specifications and suboptimal temperature differential across the evaporator coil. Customer declined recommended repairs at this time, opting to pursue system replacement in the fall season.
Responded to water leak under bar sink in basement. Upon inspection, discovered that a hammer arrestor previously installed had failed at the 1/2 inch polypropylene adapter connection, causing active water leakage. Removed the defective hammer arrestor assembly and replaced the failed PP adapter and associated components. Installed new braided flexible supply lines and verified all compression fittings on copper piping were secure. Tested system under full water pressure to confirm leak was resolved. Referred water damage restoration to appropriate contractor. Work performed under warranty coverage.
Responded to a water leak originating from an upstairs shower trap that was dripping into the downstairs bathroom. Upon inspection, identified a faulty tub waste and overflow assembly as the source of the leak. Presented repair options to the customer and proceeded with the replacement of the complete tub waste and overflow system. Successfully installed new chrome-plated waste and overflow assembly, ensuring proper sealing and drainage function. Tested the installation for leaks and verified the repair eliminated water intrusion to the lower level.
Responded to no cooling call on geothermal HVAC system that would not maintain temperature below 75°F with non-operational loop. Diagnosed and cleared plugged condensate drain line, performed thorough condensate system cleaning, and verified proper drainage function before completing service. Unit restored to normal cooling operation.
Completed comprehensive plumbing inspection of residential water treatment system. Replaced filters on reverse osmosis unit, including sediment and carbon filters, as well as water softener filter cartridge. All filter media was sourced and installed per manufacturer specifications to maintain optimal water quality and system performance.
Replaced defective high limit safety switch on Lennox furnace under manufacturer part warranty. Installed new high limit switch, verified all electrical connections, and performed operational testing to confirm proper system function. Unit is operating within normal parameters.
Responded to standing water issue around furnace base in basement. Upon inspection, discovered condensate pump running continuously but failing to discharge water due to clogged backflow preventer blocking water flow. Disassembled condensate pump assembly, thoroughly cleaned all components including backflow preventer, and reassembled system. Tested operation by adding water to condensate pump reservoir and verified proper pumping function and drainage to discharge point. System now operating correctly with no water accumulation.