Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Responded to upstairs toilet leaking into ceiling below. Removed toilet to diagnose issue and found cast-iron repair flange loose and rocking excessively. Secured and tightened repair flange to cast-iron drain to ensure stable connection. Reset toilet with proper shimming to achieve level installation and prevent future movement. Performed multiple flush tests to verify watertight seal. Additionally replaced deteriorated fill valve to restore proper tank function.
Responded to service call for toilet not flushing properly with handle feeling unstable. Upon inspection, identified unit as Mansfield model toilet with worn flush valve gasket causing flush failure. Removed old deteriorated gasket showing significant wear and mineral buildup. Installed new Mansfield-compatible flush valve gasket and tested flush mechanism for proper operation. Toilet now flushing correctly with restored handle functionality. Provided replacement toilet options but repair was completed per customer preference.
Responded to service call for two toilet installations following customer's removal of basement toilet after new flooring installation. Successfully completed installation of first toilet in bathroom with new laminate flooring, ensuring proper seating, seal integrity, and secure mounting to flange. Second toilet location required additional work beyond initial scope; performed inspection of flange condition and subfloor preparation, noting rust staining and potential flange repair needs. Provided estimate for completion of second toilet installation with necessary preparatory repairs.
Responded to multiple A.O. Smith Vertex 199 MBtu tankless water heaters experiencing simultaneous performance issues. Verified gas fuel pressure at inlet and discovered pressure dropping significantly below the required minimum of 1 inch water column during operation. Attempted to boost gas pressure to restore proper function, but units continued to fail under load conditions. Diagnosed inadequate gas supply as root cause affecting multiple water heaters concurrently. Documented existing conditions including water heater installations, gas piping system, pressure regulation equipment, and utility connections. Provided quote for necessary gas supply system repairs to restore proper operating pressure and water heater functionality.
Responded to no-cooling complaint on approximately 35-year-old system where outdoor fan operates but compressor fails to start. Upon arrival, delayed initial inspection due to severe lightning and heavy rain for safety. After weather cleared, began diagnostic evaluation and discovered unit lacks proper disconnect switch at condenser, with unclear power shutoff location at pole-mounted electrical equipment. Observed evaporator coil freeze-up and oil residue on suction line indicating potential refrigerant leak. Unable to complete full diagnostic or repairs due to unsafe electrical configuration requiring licensed electrician to establish proper disconnect and verify power source before proceeding with compressor circuit testing. Recommended electrical service prior to HVAC repairs to address failed compressor start (suspected capacitor failure) and low refrigerant charge.
Responded to no cooling complaint on 29-year-old R-22 system. Upon inspection, found unit operating with critically low refrigerant charge at approximately 7 psi suction pressure, indicating system was nearly flat. Diagnosed significant refrigerant leak in aging system that reportedly requires annual recharging. Educated customer on closed-loop refrigerant system operation, explaining that recurring annual refrigerant loss indicates substantial leak requiring repair rather than simple recharge. Discussed R-22 phase-out status and obsolescence, recommending system replacement evaluation given age of equipment and discontinued refrigerant type. Provided repair options and replacement recommendations to prevent potential compressor damage from continued low-charge operation. Customer declined service and opted to pursue alternative service provider. Recommended shutting down system to prevent further component damage until proper repairs completed, but customer declined any further action
Responded to gas leak complaint at water heater location where odor was detected outside when unit operated. Upon investigation, determined that incorrect fuel type water heater had been installed - natural gas unit was present where propane unit was required. Coordinated with team to obtain correct propane water heater for replacement. Drained existing natural gas water heater and disconnected all plumbing connections in preparation for removal. Assisted with removal of incorrect unit and installation of proper propane water heater to resolve gas leak issue and ensure safe operation.
Responded to emergency water leak call with water actively damaging flooring from dishwasher area. Upon inspection, determined leak originated from the dishwasher unit itself rather than kitchen sink plumbing. Located and shut off dedicated water supply valve to dishwasher to stop active leak and prevent further water damage to flooring. Confirmed shutoff valve was functioning properly and leak was fully stopped. Advised customer that dishwasher repair falls outside scope of plumbing services and recommended contacting appliance repair specialist. Provided option for dishwasher replacement installation if appliance deemed non-repairable.
Completed comprehensive AC tune-up and maintenance service on residential cooling system. Performed thorough inspection of outdoor condensing unit including washing exterior coils, testing electrical components and connections, and verifying all measurements within manufacturer specifications. System demonstrated proper operation with 19-degree temperature differential across evaporator coil, confirming optimal cooling performance.
Responded to no cooling complaint on 12+ year old system where condenser fan would not run but unit attempted to start with humming noise. Diagnosed failed capacitor on outdoor condenser unit, which had visibly failed. Replaced capacitor and restored normal operation. Verified system performance with temperature drop measurement of 14°, which was acceptable given extremely high ambient humidity levels and elevated dewpoint conditions at time of testing. Performed condenser coil cleaning as part of maintenance membership benefits. System operating normally upon completion, with recommendation to monitor performance and recheck if cooling issues persist once humidity levels normalize.
Responded to emergency water heater failure with severe leaking from tank bottom and ruptured condition causing water discharge onto basement floor. Removed and replaced failed 40-gallon natural gas Bradford White water heater with new unit, including all necessary connections to existing copper supply lines and gas piping. Completed installation with proper venting, pressure relief valve assembly, drain valve configuration, and tested all connections for leaks and proper operation.
Responded to service call for newly installed Mitsubishi mini-split system with no heating or cooling operation. Diagnosed wiring issue at indoor air handler terminal connections and corrected wire assignments between heads A and B at the control panel. Verified proper operation of both zones, confirmed condensate drainage from drain lines, and identified improper condensate discharge onto window sill requiring installer callback to install PVC drainage piping away from building structure to prevent wood damage.
Responded to no cooling complaint on 20-year-old AC system where condenser fan was running but compressor would not engage. Found contactor with excessive residue buildup preventing proper closure and electrical contact. Performed temporary cleaning of contactor contacts to restore immediate functionality. Advised that contactor requires replacement due to age and condition, noting unit utilizes 120V coil contactor which may require special ordering. System restored to operational status temporarily, but recommended replacement of failed component for reliable long-term operation.
Replaced failed exterior hose bibb with new frost-free model to eliminate the need for seasonal water shut-off and prevent freeze damage during winter months. The original hose bibb was malfunctioning and required complete replacement. Installation of the frost-free hose bibb was completed successfully, providing year-round outdoor water access with built-in freeze protection.
Responded to return visit for ongoing geothermal cooling issues following two previous service calls within the past month. Upon arrival, performed comprehensive system diagnostics including loop field temperature and pressure verification—all readings within manufacturer specifications. Found unit in low pressure lockout condition. Conducted thorough inspection of all geothermal unit components and confirmed proper operation once reset. Instructed homeowner on manual reset procedure using circuit breaker for future lockout conditions. Due to intermittent nature of fault and unit age of 22 years, recommended scheduling consultation for replacement options including new geothermal system or conventional HVAC equipment, as unit has reached expected end of service life and fault may not manifest during service visits.
Responded to a leaking exterior hose bibb and associated interior shut-off valve. Upon inspection, determined both the outdoor hose bibb and indoor shut-off valve required replacement due to active leaks. Successfully removed the failed hose bibb and shut-off valve, then installed new units to restore proper function and eliminate all leaking.
Responded to no cooling complaint on 15-year-old split system. Found unit low on refrigerant charge due to known leak in wall line set. Recharged system to manufacturer specifications and added UV dye to aid in future leak detection. System restored to cooling operation; however, replacement recommended due to age and ongoing chronic refrigerant loss requiring annual recharging.
Responded to emergency water leak caused by damaged PVC supply line to washing machine, which occurred during appliance installation by third-party installers. Replaced broken water line and installed new shutoff valves to restore proper water supply and prevent future leaks. All connections tested and verified leak-free upon completion.
Responded to no cooling call on 3-year-old heat pump system. Upon arrival, found indoor air handler fan operational but no outdoor unit engagement. Diagnosed faulty air handler control board preventing Y call signal from reaching outdoor condenser unit. Board failed to send cooling call to outdoor unit despite receiving proper thermostat signal. Performed temporary repair by relocating Y1, Y2, and reversing valve (O) wires from defective board to separate terminal block where thermostat connects directly. Jumpered O wire to 24V common to maintain reversing valve in cooling position. System restored to operational cooling mode. Recommended ordering and installing new air handler control board for permanent repair.
Completed preventive maintenance tune-up on residential standby generator unit as part of priority maintenance agreement. Found and replaced dirty air filter; advised customer to change filter monthly to maintain optimal performance and prevent system strain. Inspected electrical control panel, circuit boards, capacitors, and all wiring connections, confirming all components operating within normal parameters.