Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Performed comprehensive air conditioning tune-up and maintenance on 3-year-old Lennox system. Completed full system cleaning and operational check of all AC components, including inspection of electrical connections, refrigerant levels, and airflow performance. System operating within normal parameters with no deficiencies noted.
# HVAC Service Completed Responded to no cooling call on 40-year-old residential air conditioning system. Upon arrival, confirmed unit would not start. Performed comprehensive diagnostic evaluation of outdoor condenser unit, which showed significant age-related deterioration including extensive rust on fan grille and overall weathering of cabinet. Testing revealed failed contactor preventing system startup. Used digital multimeter to measure run capacitor, which tested at 24.17 microfarads, significantly below manufacturer specifications, confirming capacitor failure. Visual inspection identified failing condenser fan motor showing signs of wear and reduced operational capacity. Given the system's age at 40 years—well beyond typical 15-20 year equipment lifespan—and multiple simultaneous component failures, advised customer that repair costs would be substantial with limited long-term reliability. Discussed that even with component replacement, additional failures are likely imminen
Replaced malfunctioning Honeywell ZD20X8TZ zone damper serving the basement area. Installed new damper unit, verified proper mounting and wiring connections, and tested full open/close operation to confirm system functionality.
Completed routine cooling maintenance on a 22-year-old R22 air conditioning system. Obtained equipment documentation photos of make, model, and serial number information. Testing revealed the dual capacitor was operating outside manufacturer specifications, which was replaced to restore proper system operation. Comfort advisor was scheduled due to the age of the unit and R22 refrigerant type.
Responded to no cooling complaint on 3-year-old air conditioning system. Found debris lodged in contactor preventing proper electrical contact. Removed debris from contactor assembly, verified all electrical connections, and tested system operation. Unit restored to normal cooling function with contactor making proper contact and compressor running as designed.
Responded to no cooling complaint on Gibson condensing unit at residential property. Upon arrival, discovered no high voltage power to outdoor condenser. Found circuit breaker in off position and attempted to restore power by resetting breaker multiple times, but unit failed to receive power. Confirmed electrical fault preventing power delivery to condensing unit. Left disconnect switch in off position for safety until electrical issues can be resolved. Coordinated with electrician for follow-up service to diagnose breaker failure and evaluate existing knob and tube wiring that requires replacement. Unit remains non-operational pending electrical repairs to restore proper power supply to condensing unit.
Responded to warranty call for 12-5 Mitsubishi mini split system installed two months prior with water leaking from indoor unit on east side of home. Inspected system and traced issue to improper condensate drainage at outdoor unit. Found condensate line had improper pitch with upward curve causing water backup. Cut back approximately one foot of exterior condensate line to establish proper downward slope for gravity drainage. System drained accumulated water for approximately one minute and indoor unit leak resolved. Verified proper drainage operation and system returned to normal function.
Responded to no hot water complaint affecting entire home. Upon inspection of Richmond brand tanked water heater, determined unit had no electrical power supply. Verified water heater installation with proper copper piping connections and seismic restraint strapping in place. Advised customer that electrical issue requires licensed electrician to diagnose and restore power to unit before water heater can operate.
Responded to no cooling complaint on 9-year-old system at rental property. Upon arrival, found thermostat control wire completely severed at exterior penetration. Repaired wire by splicing and reconnecting to restore communication between thermostat and outdoor unit. Once system was operational, performed diagnostic testing with manifold gauges and confirmed system was operating with low refrigerant charge. System utilizes R-22 refrigerant. Coordinated with property owner to schedule service advisor appointment to discuss options for refrigerant recharge or further system evaluation. System left in safe operating condition pending owner decision on refrigerant service.
Responded to no hot water call on electric American Polaris water heater system with integrated air coil assembly. Upon inspection, discovered significant leaking from the air coil unit mounted on top of the water heater, with visible moisture and condensation present on connected piping. Confirmed complete loss of hot water functionality. Documented system configuration including all plumbing connections, ductwork, and air handler components. Awaiting property management authorization and confirmation of replacement unit availability on-site before proceeding with repair or replacement recommendations.
Completed air conditioning tune-up on outdoor condensing unit. During inspection, found the capacitor reading out of specification and replaced it with a new unit. Performed coil cleaning, washed the exterior unit, and verified proper system operation upon completion.
Responded to service call for assistance with Rusco spin-down sediment filter maintenance on residential well water system. Upon arrival, determined homeowner had been rotating filter housing in incorrect direction, resulting in overtightening rather than removal. Successfully loosened filter housing and demonstrated proper removal technique and rotation direction for future maintenance. Removed and inspected internal stainless steel screen element, showing homeowner correct cleaning procedure for sediment removal. Filter housing and screen were in good condition with no damage from overtightening. Reassembled unit properly and verified system operation with no leaks. Provided instruction on routine maintenance intervals and proper disassembly/reassembly procedures to ensure homeowner can independently perform future filter cleaning.
Responded to customer complaint of high-pitched, steady whistling noise occurring when air conditioning system activated and during operation. Upon inspection of Lennox furnace system, identified improperly seated air filter as source of noise. Repositioned filter to proper seated position within filter rack, eliminating air bypass and resolving whistling noise completely.
Responded to no-cooling complaint on 30-year-old air conditioning unit. Upon inspection, found compressor not operating due to failed capacitor leaking oil and rodent-damaged wiring. Repaired chewed wire and replaced defective capacitor. System restarted with outdoor fan operating, but compressor experienced delayed startup, indicating impending compressor failure. Advised customer that compressor is deteriorating and recommended obtaining replacement pricing due to age of unit and declining compressor performance.
Responded to repeat no-water issue at residence with well system. Verified electrical power supply to home was functioning properly. Based on recurring nature of problem and previous service call where tripped breaker was identified, recommended homeowner contact licensed well service company for comprehensive system evaluation and repair, as issue appears to be related to well pump or well-specific components beyond scope of general plumbing service.
Responded to a water heater leak at a residential property. Upon inspection, identified a 45-gallon natural gas power vent water heater, over 10 years old, actively leaking from the top connections. Determined the unit required full replacement due to age and extent of deterioration. Documented the existing A.O. Smith power vent installation with photographs showing the leaking connections, power vent motor assembly, copper supply lines, and overall system configuration. Provided replacement options for both 40-gallon and 50-gallon natural gas power vent units suitable for the existing installation location and venting requirements. Awaiting customer decision on replacement sizing and scheduling.
Responded to no cooling complaint on 10+ year old residential air conditioning system. Upon inspection of outdoor condensing unit, discovered one leg of power supply to contactor had melted and burnt off due to loose connection. Diagnosed failed contactor with burnt wiring requiring replacement. Documented findings with photos and contacted homeowner with repair recommendations. Customer declined service at this time to research options. Unit remains non-operational pending contactor and wiring repair.
Responded to no cooling complaint on 10+ year old R22 air conditioning system that had previously frozen up. Upon arrival, system had been off and evaporator coil was fully thawed. Performed diagnostic testing using refrigerant manifold and gauges, which revealed system was significantly low on R22 refrigerant charge. Measured operating pressures and temperatures on both low and high side of system. Low refrigerant charge was determined to be primary cause of freezing and loss of cooling capacity. Added R22 refrigerant to bring system back to proper operating charge levels. Verified proper system operation with corrected pressures and temperatures after recharge. System restored to normal cooling operation.
Responded to no cooling complaint on 2021 Amana air conditioning system with condenser fan running but no interior cooling. Diagnostic testing revealed failed dual run capacitor rated 40/5 µF—compressor section measured 0 µF while fan section read 5 µF. Replaced defective capacitor with new 40/5 µF unit, restarted system, and verified proper operation with 20°F supply/return temperature split after ten minutes of runtime. System restored to normal cooling operation.
Removed and replaced existing toilet with customer-provided fixture in commercial restroom facility. Installation included proper seating, wax ring replacement, water supply connection, and verification of proper flush operation and seal integrity.