Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Our HVAC repair services are tailored to ensure your heating, ventilation, and air conditioning systems operate at peak efficiency and comfort. Our skilled technicians possess extensive experience in diagnosing and fixing a wide array of heating and AC repair issues, from minor malfunctions to major breakdowns. We prioritize prompt response and timely repairs to restore your system’s functionality swiftly.
Our services encompass a thorough assessment of your heating and cooling system, identifying the root cause of any problems before implementing efficient and effective air conditioner and heating repair solutions. Whether it’s a faulty thermostat, a malfunctioning compressor, air duct issues, or refrigerant leaks, we have the expertise to address them all. We use top-quality replacement parts and advanced tools to guarantee lasting repairs and improved system performance.
Furthermore, we strive to educate our clients on preventive heating tune-ups and air conditioning maintenance to minimize future breakdowns and extend the lifespan of their HVAC systems. Our commitment to customer satisfaction, expertise in the field, and dedication to excellence set us apart as a trusted HVAC repair service provider.
Our HVAC installation services encompass a wide array of offerings to cater to your heating and cooling needs. Our team excels in air conditioning installation, ensuring a smooth and efficient process when integrating new AC units into your space.
If you require air conditioning replacement or are looking to upgrade to a more energy-efficient model, we’re here to guide you through the selection process and execute a seamless AC replacement. Our expertise in central air installation solutions allows for consistent and effective cooling throughout your property.
We understand the importance of a well-functioning heating and cooling system, which is why we specialize in air conditioner replacement, HVAC replacement, and furnace replacement, providing you with top-tier service to enhance your comfort and efficiency.
During the colder Wisconsin months, the humidity levels outside and inside of your home can also fluctuate. To combat this issue, we provide whole home humidifier and whole home dehumidifier options. Whether your home has an excess or a deficit of humidity, our indoor air quality servicescan provide a solution. If your home’s humidity is as it should be, but you are still seeking to improve your indoor air quality, we also offer UV light air purifier installations.
In Menomonie, WI, Hurlburt delivers a comprehensive suite of electrical services to ensure the safe and efficient operation of your home’s electrical systems.
Our expert technicians perform precise electrical repairs to solve urgent problems and install whole-home generators to provide continuous power during electrical outages.
We offer critical services for electrical panels, the cornerstone of your home’s electrical system, to protect against hazards and enhance electrical functionality. Whether you are updating your panel for additional appliances or ensuring compliance with safety regulations, Hurlburt’s team offers confidence with every visit.
We deliver outstanding electrical installation services that cater to enhancing both the comfort and functionality of your home. Whether it’s the installation of transformative new lighting or the addition of outlets to support various devices, Hurlburt’s adept team is ready to assist.
We also excel in the installation of ceiling fans, which promote a comfortable living environment and better energy efficiency. With a focus on safe and meticulous installations, Hurlburt ensures all services are implemented perfectly to integrate effortlessly into your lifestyle.
People in Menomonie, WI can enjoy duct cleaning services that boost the efficiency of air conditioning units and improve the air quality their your home. When ducts accumulate dust, allergens, and debris, they can obstruct airflow and diminish HVAC efficiency.
Hurlburt’s duct cleaning restores airflow to optimal levels, ensuring maximum efficiency of your air conditioning system. This contributes to lower energy expenditures and increased system longevity. Additionally, the enhanced cleanliness of your ducts greatly betters the air quality in your home, which minimizes irritants and fosters a healthier environment.
The average HVAC repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your HVAC repair service!
HVAC installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs.The cost will be affected by a few things:
Are you interested in a new HVAC system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
The plumbing services provided by Hurlburt are designed to cover a wide spectrum of needs, ensuring a reliable and smoothly functioning water system in your home or business. Our skilled plumbers in Menomonie, WI specialize in professional plumbing repair, addressing a range of issues from minor leaks to more complex plumbing system malfunctions.
We excel in water heater installation, making sure you have a steady and efficient supply of hot water. Our team also offers options for tankless water heaters. Whether you need plumbing service for routine maintenance or emergency repairs, we are dedicated to delivering high-quality solutions that meet your unique requirements and ensure the proper functioning of your plumbing system.
Another way we can help keep your plumbing and HVAC systems protected is with our Hurlburt Family Rewards Club. As a member of our maintenance program, you will get discounts on repairs as well as annual or semi-annual servicing. To learn more about our HVAC repairoptions and plumbing services, give us a call today. To see what our loyal customers are saying about our services, read our reviews below!
Responded to no-cooling complaint on 10-year-old Lennox central air system experiencing evaporator coil icing. Performed comprehensive diagnostic including airflow verification, air filter inspection (found clean), and outdoor condenser coil evaluation and rinse-down. Connected manifold gauges to refrigerant system and identified low refrigerant charge as primary cause of cooling failure and ice formation. Discussed repair options including system recharge versus full system replacement given age of equipment. Customer declined immediate repairs and requested consultation with service advisor for new system pricing. Advised customer on temporary operation limitations until replacement decision is made.
Responded to complaint of unit running constantly without adequate cooling on 1-year-old Lennox system. Upon inspection, determined indoor blower was operating continuously. Identified thermostat fan switch had been inadvertently set to "ON" position instead of "AUTO" mode. Adjusted Honeywell Home ProSeries thermostat fan setting from continuous operation to AUTO mode, which resolved the issue immediately. Verified system now cycles properly with blower activating only during heating and cooling calls. Provided customer education on proper thermostat operation and function of fan control settings to prevent future occurrences. No mechanical defects found; unit operating within normal parameters.
Responded to callback for Steffes heat pump unit with non-functioning control board. Upon rediagnosis, identified that previously installed outdoor sensor was incorrectly connected to thermostat via Wi-Fi/Bluetooth instead of being hardwired directly to the unit's control board. Determined that correct hardwired sensor must be obtained and installed to the Steffes control board before further diagnostics can proceed. Recommended reinstalling original control board to unit. Documented equipment condition with photos for reference.
Responded to report of high-severity water leak with unknown source initially suspected to be from water heater or furnace. Upon investigation, determined leak originated in laundry room from HVAC mini giant pump discharge hose that had come out of standpipe. Leak was already addressed prior to arrival. Proceeded with scheduled replacement and installation of new iron filter as requested. Unit installed and operational.
Responded to callback for AC unit installed 13 days prior with reported basement flooding from condensate drainage issue. Upon arrival, found significant water accumulation near furnace area with floor drain backing up and unable to handle discharge volume. Documented conditions with photos showing extensive water pooling on basement floor and compromised drainage system. Diagnosed clogged floor drain as primary cause preventing proper condensate removal. Scheduled plumber to snake drain line and advised that condensate pump installation with upstairs drain routing would be required if drain clearing unsuccessful.
Responded to service call for mini split system with inadequate airflow in office area. Upon inspection, found both indoor air handler units operational but producing minimal airflow despite blower motors running. Diagnosed severely clogged blower wheels restricting air circulation in both heads. Provided updated estimate for complete blower wheel cleaning service, which was approved. System currently maintaining cooling function but operating at reduced capacity. Scheduled follow-up appointment to perform thorough cleaning of blower wheels and evaporator coils using appropriate cleaning solutions and containment equipment to restore proper airflow and system performance.
Responded to service call for furnace blower motor not operating and water dripping inside unit. Upon arrival, activated system and confirmed blower motor engaged properly. Connected manifold gauges and identified low refrigerant pressures on 31-year-old R-22 system. Conducted airflow verification and inspected filter, blower wheel, and evaporator coil for obstructions. Found minimal dust accumulation on blower wheel insufficient to cause pressure drop. Observed top half of evaporator coil not sweating, indicating partial freezing condition. Determined system is undercharged on R-22 refrigerant, causing evaporator to ice over and restrict airflow, which led to perceived blower failure. Documented extensive corrosion on unit base plate, electrical connections, and copper refrigerant lines with significant rust and oxidation present throughout equipment. Photographed deteriorated conditions showing moisture damage and age-related wear on metal components and housing. Reviewed findings in
Responded to service call for constantly running toilet and leaking outdoor hose bib. Diagnosed faulty flapper as cause of toilet issue. Addressed primary concern of exterior hose bib that continued leaking and running water after shut off. Removed defective hose bib and installed new replacement unit. Tested new hose bib for proper operation and verified no leaks upon shut off. Completed copper pipe connection work in crawl space area to ensure proper water flow and eliminate leakage issues.
Responded to no cooling complaint on 3-year-old HVAC system experiencing reduced airflow and inability to maintain temperature. Upon inspection, discovered excessive condensation and moisture accumulation in furnace cabinet caused by humidifier bypass damper left open in summer mode. Cold supply air mixing with warm, humid outside air through open damper created condensation on ductwork and components, resulting in visible rust on metal pipes and moisture throughout electrical compartment. Verified system producing proper 20-degree temperature split, confirming cooling function operational. Closed humidifier bypass damper to winter position to prevent continued moisture infiltration. Instructed homeowner on proper seasonal damper operation and recommended removing top access door temporarily to allow trapped moisture to evaporate and cabinet to dry completely, preventing further corrosion of components.
Completed follow-up visit on recent HVAC installation. Installed new RDS sensor on coil to replace defective unit. Upon arrival, discovered customer was expecting furnace tune-up and repair of leaking collector box based on previous communication with installation team. Performed inspection of collector box and identified active leak requiring replacement. Captured photographs of equipment model and serial number information and forwarded to parts department for replacement collector box quote.
Responded to a leaking shower complaint and diagnosed a faulty cartridge as the source of the leak. Removed the defective cartridge and installed a replacement unit, restoring proper function to the shower system. The dual showerhead fixture now operates without leakage.
Responded to warranty call for AC system installed in May 2026 not maintaining temperature during high ambient conditions. Performed comprehensive system evaluation including visual inspection of attic-mounted equipment and ductwork. Measured and documented temperature differentials and system performance parameters using calibrated digital instruments. Observed installation conditions and equipment placement in unconditioned space with surrounding fiberglass insulation. Assessed mechanical components, refrigerant lines with foil-wrapped insulation, electrical connections, and supporting infrastructure in crawl space area. Documented findings with detailed photographs of equipment location, structural mounting, and overall installation quality. Completed follow-up form for installation team review to address performance concerns and ensure system meets design specifications for proper cooling capacity in current weather conditions.
Replaced control board on heat pump air handler due to system malfunction. After installation, discovered the new board exhibited the same issue as the original, failing to send 24V signal to the outdoor condensing unit. Implemented temporary solution by directly wiring the outdoor unit's thermostat wiring to the thermostat terminals on the control board, restoring cooling operation while both boards remain installed pending further diagnosis.
Completed annual air conditioning tuneup on 11-year-old Lennox outdoor condensing unit. Performed comprehensive system inspection and testing with all electrical components measuring within manufacturer specifications. Cleaned and washed outdoor unit coil and cabinet to ensure optimal airflow and heat transfer. Unit operating properly with no deficiencies noted at time of service.
Replaced IBC indirect water heater tank under manufacturer parts warranty, including complete removal and disposal of failed unit. During system restoration, the backflow preventer began leaking upon water supply activation, requiring immediate replacement with new brass backflow prevention device. Installed new indirect water heater with expansion tank, connected all copper piping, and verified proper integration with existing IBC boiler system. Purged air from hydronic heating system, tested all heating zones for proper operation, and confirmed system pressure stabilized at 22 PSI. All components functioning within normal parameters upon completion.
Completed comprehensive AC tune-up on Lennox system. Identified and resolved condensate drainage issue caused by pinched hose at furnace corner—repositioned hose to eliminate restriction and restore proper drainage flow. Performed outdoor unit cleaning, conducted electrical testing with all readings within manufacturer specifications, and verified system performance with 20-degree temperature split across coil.
Completed comprehensive AC tune-up maintenance agreement including filter replacement, blower inspection, and evaporator coil evaluation which was found clean and draining properly. Performed routine electrical component inspection on outdoor unit, cleaned condenser coils, and conducted operational testing with 15-minute run cycle confirming proper system performance with 17-18 degree temperature differential. Addressed customer concerns regarding window condensation, explaining that current high humidity levels make condensation difficult to avoid, and confirmed all equipment operating within normal parameters.
Responded to a bathroom plumbing emergency where both the bathtub and toilets were not draining properly. Upon arrival, confirmed that the tub had stopped draining mid-shower and multiple fixtures in the bathroom were experiencing severe drainage issues. The homeowner had previously attempted to clear the blockage using a chemical drain cleaner (Green Goblin), which provided minimal temporary relief but did not resolve the underlying obstruction. Assessed the situation and determined that the clog was affecting multiple fixtures simultaneously, indicating a main drain line blockage beyond the scope of standard drain cleaning methods. Due to the severity and location of the blockage in the drainage system, the job required specialized equipment and techniques beyond what was available on-site. Documented the condition of the affected fixtures with photographs and referred the customer to a specialist drain cleaning service (Roto-Rooter) equipped with professional-grade augering and
Responded to water leak in south utility room identified in home inspection report. Replaced leaking valve behind structural beam and installed proper discharge piping for water heater temperature and pressure relief valve, which was previously missing and posed a safety hazard.
Performed comprehensive air conditioning tune-up and maintenance on 3-year-old Lennox system. Completed full system cleaning and operational check of all AC components, including inspection of electrical connections, refrigerant levels, and airflow performance. System operating within normal parameters with no deficiencies noted.