Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Responded to no cooling call on geothermal HVAC system that would not maintain temperature below 75°F with non-operational loop. Diagnosed and cleared plugged condensate drain line, performed thorough condensate system cleaning, and verified proper drainage function before completing service. Unit restored to normal cooling operation.
Completed comprehensive plumbing inspection of residential water treatment system. Replaced filters on reverse osmosis unit, including sediment and carbon filters, as well as water softener filter cartridge. All filter media was sourced and installed per manufacturer specifications to maintain optimal water quality and system performance.
Replaced defective high limit safety switch on Lennox furnace under manufacturer part warranty. Installed new high limit switch, verified all electrical connections, and performed operational testing to confirm proper system function. Unit is operating within normal parameters.
Responded to standing water issue around furnace base in basement. Upon inspection, discovered condensate pump running continuously but failing to discharge water due to clogged backflow preventer blocking water flow. Disassembled condensate pump assembly, thoroughly cleaned all components including backflow preventer, and reassembled system. Tested operation by adding water to condensate pump reservoir and verified proper pumping function and drainage to discharge point. System now operating correctly with no water accumulation.
Responded to commercial water leak emergency at hotel guest room on third floor. Upon arrival, found CPVC waterline broken off behind toilet within wall cavity. Water supply had been shut off prior to arrival. Inspection revealed the CPVC line had fractured at mounting point, likely due to excessive force during toilet removal combined with material brittleness from age. Removed damaged section of CPVC waterline and made clean cut to establish solid connection point. Installed PEX adapter fitting to transition from existing CPVC to new PEX piping. Stubbed out new waterline to proper location and installed new shut-off valve. Restored water supply to fixture and conducted 10-minute pressure test to verify system integrity and confirm no active leaks at repair points or connections.
Performed routine maintenance on existing mini-split system including cleaning air filters, washing condenser coil, inspecting for rodent activity, and verifying condensate drain operation. Upon testing, discovered inadequate temperature differential across indoor units and confirmed system was low on refrigerant charge. Conducted thorough leak detection using electronic leak detector and UV light inspection of existing fluorescent dye at all flare connections, outdoor unit, and indoor heads with no leaks detected. Provided customer with pricing options for refrigerant recharge and scheduled follow-up with service advisor.
Performed comprehensive boiler tune-up on hydronic in-floor heating system. Removed burner assembly from heat exchanger, thoroughly cleaned heat exchanger components, and flushed system with water to remove accumulated debris and sediment. Cleaned flame sensor and igniter, reassembled all components, and started unit to verify proper operation. System brought to full operating temperature and confirmed running within normal parameters with all circulation pumps and controls functioning correctly.
Replaced failed igniter on 4-year-old IBC boiler that had experienced ongoing operational issues since original installation. Installed new dual probe igniter under full warranty coverage, completed startup procedures, and monitored unit operation for 20 minutes to verify consistent performance and proper functionality with no issues detected.
Responded to urgent leak under commercial kitchen sink that was causing water spillage onto the floor. Upon inspection, identified that the kitchen sink strainer had rotted out along with the connected piping leading to the T-fitting beneath the sink. Measured the existing sink strainer and determined it to be a non-standard 2-3/4 inch outside diameter size. Documented the deteriorated components with photographs showing the corroded strainer opening and measuring the dimensions for proper replacement parts. Submitted parts order request for the specialty-sized sink strainer and associated piping materials. Prepared estimate for the complete repair work, which will include removal of the failed strainer, installation of new strainer assembly, and replacement of deteriorated piping from the sink drain to the existing T-connection underneath the commercial sink.
Responded to active water leak on refrigerator ice maker supply line. Upon arrival, found homeowner had already shut off water to the affected area. Inspection revealed a failed saddle valve on the copper waterline causing the leak. Removed the defective saddle valve and installed a new replacement valve to restore water supply to the ice maker. Tested the new installation for proper operation and verified no leaks were present. Photographed the completed work showing the new valve installation and surrounding plumbing connections. Additionally provided an estimate for water treatment services based on observations during the service call.
Responded to low water pressure complaint at pantry faucet, which was the only affected fixture in the home. Diagnosed issue as malfunctioning faucet sprayer with stuck/broken button mechanism causing restricted flow to main spout. Advised customer to contact faucet manufacturer for replacement sprayer component, as the faucet body and supply lines were functioning properly.
Responded to callback for recently installed furnace and AC system with inadequate cooling performance. Upon inspection, identified insufficient airflow through the system as the primary issue. Documented internal components and measurements, confirming installation deficiencies requiring correction by installation crew to restore proper system operation and achieve manufacturer specifications.
Completed annual AC tune-up on 1-year-old furnace replacement system as part of maintenance agreement. Performed comprehensive inspection per standard maintenance form, verified all components operating within normal parameters, and documented equipment condition with photos.
Responded to service call for toilet reseating evaluation. Upon arrival, removed toilet to inspect subfloor mounting system and discovered severely deteriorated toilet flange with visible cracking and extensive rust corrosion around mounting holes. The PVC flange exhibited structural damage and compromised integrity due to age and water exposure. Documented existing conditions through photography showing corroded flange, deteriorated mounting surface, and surrounding concrete substrate damage. Provided comprehensive estimates covering three options: repair and replacement of damaged toilet flange with reinstallation of existing toilet fixture, complete flange replacement with new toilet installation, and assessment of subfloor conditions requiring remediation prior to fixture reinstallation. Explained that proper flange replacement would require removal of damaged component, cleaning of drain pipe connection, installation of new flange assembly with secure fastening to subfloor, new wa
Completed comprehensive HVAC maintenance on a 13-year-old furnace and 24-year-old Amana air conditioning system as part of routine maintenance agreement. Performed thorough inspection revealing dirty burners on the furnace and pitted contactor on the AC unit. Cleaned burners to restore proper combustion efficiency and replaced worn contactor to ensure reliable compressor operation. Verified system levelness, inspected electrical connections and capacitor, and confirmed all components operating within specifications upon completion.
Performed comprehensive AC tune-up on residential cooling system. Removed exterior panels and rinsed condenser coil, inspected all electrical components with capacitor testing within specification, and verified system cleanliness. Proceeded to indoor unit where recently replaced filter was confirmed, checked blower speeds and wheel for proper operation and cleanliness, and cleared evaporator coil drain line. System startup confirmed proper operation with 20-degree temperature differential across coil, indicating optimal performance with no deficiencies noted.
Responded to service call for boiler making abnormal noise during operation. Upon arrival, activated system and observed vibration-type noise with flame rollback that stabilized after brief runtime. Performed comprehensive diagnostics including combustion analysis and gas valve testing, which confirmed proper operation of both components. Consulted with technical support regarding intermittent noise issue that has persisted since installation seven years ago. Based on technical recommendation and diagnostic findings, upgraded single-prong igniter to dual-prong igniter assembly to resolve ignition stability and noise concerns. System tested successfully following igniter replacement with normal operation confirmed. Documented conditions with photos for service records.
Responded to service call regarding intermittent gas odor detected near recently installed Navien tankless water heater. Performed thorough inspection of unit and all gas connections to identify potential leak or installation defect. Conducted operational test of water heater, verifying proper combustion, venting, and exhaust function. All gas connections tested and confirmed secure with no leaks detected. Unit operating within normal parameters with appropriate flame characteristics and exhaust discharge. Explained to customer that odor detected is normal exhaust smell from tankless water heater combustion process, particularly noticeable during initial break-in period and when unit cycles on. Confirmed proper installation of venting system and adequate clearances around exhaust termination. No safety concerns identified. Unit functioning as designed.
Responded to emergency call for leaking toilet causing water to flow into hallway at commercial office building. Upon arrival, building occupants had already shut off water supply to prevent further damage. Diagnosed failed toilet supply line as source of leak. Removed defective braided flexible supply line and installed new replacement, restoring proper connection between wall-mounted shut-off valve and toilet tank inlet. Verified all connections were secure, turned water supply back on, and tested system to confirm leak was eliminated and toilet was functioning properly.
Completed comprehensive maintenance inspection on 30-year-old residential HVAC system utilizing R22 refrigerant. Replaced failed dual capacitor and contactor due to significant corrosion and electrical deterioration observed at connection points. Performed standard air conditioning and furnace tune-up procedures including filter inspection, electrical connection evaluation, and system operational testing. Customer advised that unit is original equipment and plans to operate system until complete failure. Documentation provided to comfort advisor for future replacement consultation given advanced age of equipment and obsolete refrigerant type.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.