We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The weather in Mendota Heights tends to be chilly for much of the year. Heavy snowfall creates ideal conditions for skiing at places like Afton Alps or Welch Village. The freezing temperatures also make for great ice fishing at Rogers Lake. However, this cold weather can pose a challenge to homeowners. You’ll need a dependable heating system to keep your property warm and cozy during the winter. With our help, you’ll be able to heat your home without worrying about utility expenses going through the roof.
Turn To Our Heating Services For Great Results
- Heating repair: Problems like a malfunctioning heat exchanger or a failing blower motor make the heater use more energy, wearing out its parts faster. We can address these problems and others, like ignition failures, uneven heating, or strange noises coming from the system.
- Heating installation: We’ll help you select the best heating system for your house based on factors like its square footage, insulation quality, and existing ductwork. We can also assess your property for a heat pump. A heat pump is a great idea for many homes because it can reverse itself during the summer to provide cooling.
- Heating maintenance: One of the easiest ways to help your heater perform better is to sign up for our Hurlburt Family Rewards Program. We’ll clean the whole system and add lubrication to its moving parts once a year so it achieves peak efficiency at all times.
- Indoor air quality
Your cooling system greatly affects your sleep quality and overall health during the warm weather seasons. We offer services that fix issues like refrigerant leaks so your home stays cool, even when it gets really hot. With our installation help, you can be certain that your property will have the best AC right from the start. It will be much easier to unwind and rest since your home will be cool and comfortable. Plus, you won’t have to worry about the AC constantly breaking down. This gives you more energy and time to check out some of Mendota Heights’ best attractions, like Mendakota Park and Friendly Marsh Park.
We Provide a Wide Range of Trusted Cooling Services
- Cooling repair: Don’t let a failing compressor or clogged condensate drain line impact your home’s cooling. Our experts offer repairs to fix these issues and many others.
- Cooling installation: The wrong size AC can cause major problems, like inefficient cooling or excessive energy consumption. Need help choosing the right model? We’ll consider many factors to ensure you get the right size and type of cooling system for your house.
- Cooling maintenance: It’s easy to boost the performance of your AC with our maintenance. We even offer the Hurlburt Family Rewards Program to provide exclusive discounts and priority service.
See all of our HVAC services in Mendota Heights.
Water leaks and pipe corrosion can cause major damage to your home, affecting its foundation, walls, and structural integrity. Leaks can also harm your health by promoting mold growth. The plumbers at Hurlburt know how to find hidden leaks to prevent costly water damage. We even provide emergency plumbing for leaks and plumbing problems that cause flooding. Our water treatment solutions will improve your home’s water quality and help prolong your plumbing system’s lifespan.
See all of our plumbing services in Mendota Heights.
There are so many ways a Hurlburt electrician can make your home more efficient, safe, and convenient. We can add smart outlets so you can easily control appliances with your smartphone. Installing smart lights is a great way to enhance security and customize the brightness in each room. Our team also handles lighting installations for decorative, outdoor, and under-cabinet fixtures. Want to ensure your house will have power during a power outage in the Twin Cities area? We can install a dependable whole-home backup generator.
Our professionals service all of Mendota Heights and its many neighborhoods. We want you to have a home where you enjoy spending time and relaxing. Our plumbing, electrical, and HVAC services help homeowners just like you create optimal living spaces with the latest amenities.
We want to welcome you to the Hurlburt Family! Our team always strives to exceed customer expectations. That’s why we’ve received more than 6,000 5-star reviews. Our commitment to making the local community a better place to live drives us to deliver exceptional service every day.
Access the most honest and dependable plumbing, electrical, and HVAC company in Mendota Heights by calling Hurlburt now.
Completed annual cooling maintenance on one residential air conditioning system utilizing 410A refrigerant under Family Rewards membership agreement. Performed comprehensive inspection of indoor air handler including filter assessment, condensate drain verification, blower motor operation, and electrical wiring and component evaluation—all components found within normal operating parameters. Homeowner supplied filter for replacement during service visit. Verified temperature split across evaporator coil within acceptable range. Conducted thorough inspection of outdoor condensing unit including coil cleanliness assessment and capacitor condition check. Measured and recorded amperage draw on condenser fan motor, compressor, and contactor—all readings within manufacturer specifications. Verified refrigerant charge level appropriate for ambient temperature of 81 degrees. System demonstrated proper cooling cycle operation with Lennox smart thermostat displaying 74 degrees indoor temperature
Responded to no cooling complaint on 10-year-old Lennox air conditioning system. Upon inspection, discovered system was significantly low on refrigerant charge, indicating an active leak in the system. Verified proper airflow through evaporator coil and confirmed air filter was clean and unobstructed. Discussed leak detection and repair options with homeowner, including electronic leak search procedures and potential repair costs. Homeowner elected to schedule consultation with service advisor to evaluate replacement options rather than proceed with leak repair on existing unit. System remains non-operational pending customer decision on repair versus replacement.
Responded to no cooling complaint on Amana air conditioning system installed four years ago. Upon arrival, confirmed outdoor fan was running but unit not producing cool air. Inspected attic-mounted air handler and found it in acceptable condition. Replaced dirty air filter and proceeded to outdoor condenser unit for further diagnostics. Discovered condenser coils heavily clogged with cottonwood debris restricting airflow. Tested dual-run capacitor and found it reading 10/5 MFD against rated specification of 45/5 MFD, indicating significant capacitor degradation affecting compressor and fan motor operation. Advised customer of findings and recommended capacitor replacement and system cleaning to restore cooling function. Replaced failed dual-run capacitor with proper 45/5 MFD rated component. Thoroughly cleaned condenser coils to remove cottonwood accumulation and restore proper heat exchange. Performed complete system tune-up including all electrical connections and component inspect
Responded to multiple plumbing concerns including toilet leaks, kitchen sink faucet leak, and water hammer noise from washing machine supply lines. Replaced faulty fill valve on one toilet and tightened packing nut on leaking toilet valve to stop water seepage. Replaced leaking angle stop valve servicing upstairs bathroom fixture. Installed bidet attachment to existing toilet as requested. All repairs completed during single service visit to address immediate plumbing needs.
Responded to no cooling complaint on 2-year-old Lennox system. Upon arrival, thermostat was calling for cooling with indoor temperature at 78°F and setpoint at 73°F. Inspected indoor unit and found GFCI outlet tripped with red indicator light illuminated. Reset GFCI outlet and system powered on successfully. Verified system operation with delta-T reading of 20°F, indicating proper cooling performance. Cleaned and flushed condensation pump to ensure proper drainage. Noted air filter requires replacement and advised homeowner accordingly. Performed exterior inspection of condensing unit, confirming coils are clean, refrigerant lines properly insulated and cold to touch, and unit operating within normal parameters. System restored to full cooling operation and ready for summer season.
Responded to a non-flushing toilet issue. Upon inspection, determined the fill valve was malfunctioning and becoming stuck, preventing proper tank refilling. Removed the defective fill valve and installed a new replacement unit, restoring full functionality to the toilet's flush system.
Completed air handler tune-up with system operating efficiently and providing adequate cooling. Air filter inspected and found to be in clean condition. Outdoor condenser unit identified as requiring cleaning due to dirt accumulation, but service could not be performed due to lack of water access on roof. System performance verified satisfactory at time of service.
Responded to no cooling call on recently installed air conditioning system. Upon diagnosis, found system low on refrigerant charge and incorrect dip switch configuration preventing proper operation. Added 7 pounds of R-454B refrigerant to bring system to proper charge level. Identified and tightened loose flare connection on suction line that was causing refrigerant loss. Corrected dip switch settings to manufacturer specifications. Verified system operation with proper cooling performance restored upon completion.
Responded to water leak emergency with mitigation crew already on-site. Diagnosed dishwasher as the source of active water leak affecting kitchen flooring. Upon inspection, found dishwasher pump had failed, causing water to discharge onto floor rather than drain properly. Unit exhibited heavy accumulation of lint and debris on exterior components and housing, indicating age and lack of maintenance. Verified internal components showed water pooling in bottom basin with compromised drainage system. Pulled appliance from cabinet opening to fully assess leak source and extent of damage. Confirmed pump assembly failure as primary cause of water intrusion. Documented conditions with photographic evidence for insurance claim purposes. Recommended complete dishwasher replacement due to pump failure and overall deteriorated condition of unit.
Responded to service call for two malfunctioning Kohler toilets with fill valve failures. One toilet was completely non-functional and would not flush, while the second toilet required manual manipulation of internal components to fill intermittently. Diagnosed both units with defective fill valves and performed complete fill valve replacements on both toilets, restoring proper flush and refill operation to both fixtures.
Replaced failed S30 thermostat with new Lennox S40 model due to recurring thermostat failures. Thoroughly inspected and verified all low-voltage wiring connections at terminal block to identify potential causes of previous failures, ensuring proper wire termination and secure connections across all control circuits. Successfully commissioned new Wi-Fi enabled control board and confirmed proper system operation.
Responded to no cooling complaint on 3-year-old residential AC system. Diagnosed failed S30 communicating thermostat hub preventing system operation. Provided estimate for replacement S40 communicating thermostat to restore full system functionality.
Completed annual cooling tune-up on residential AC system, which included comprehensive inspection and testing of all components. During inspection, identified a cracked heat exchanger requiring attention, with comfort advisor scheduled for follow-up consultation. System verified to be running normally with proper cooling operation, and thermostat confirmed functioning correctly at setpoint of 70°F in cooling mode.
Performed comprehensive furnace inspection and tune-up on forced air heating system. Upon inspection, discovered critical safety hazard: cracked flue pipe with carbon monoxide levels exceeding 500 ppm. Verified gas manifold pressure within manufacturer specifications. Air filter and blower motor condition satisfactory, though blower wheel exhibited rust and dirt accumulation requiring attention. Heat exchanger inspection limited by restricted access, but visible areas showed significant soot, rust, and corrosion buildup indicating potential compromised integrity. During operational testing, observed abnormal safety control behavior—circulating blower energized within 30 seconds then shut off while burner flame remained active and rolling, indicating potential limit switch malfunction or heat exchanger failure. Due to dangerous carbon monoxide levels and unsafe operating conditions posing immediate health and safety risk, shut off gas supply to unit and red-tagged system as unsafe for
Responded to service call for ductless mini-split system maintenance. Performed comprehensive cleaning of blower wheel assembly on indoor unit, which had accumulated significant buildup affecting system performance. Thoroughly cleaned both indoor evaporator coils and outdoor condenser unit to restore proper airflow and heat exchange efficiency. Utilized protective collection tarp during service to contain water and debris. Verified electrical connections at service disconnect panel and confirmed all circuit breakers were properly functioning. System tested and returned to full operation with improved airflow and cooling capacity.
Completed comprehensive AC tune-up on Lennox system with indoor furnace and outdoor condensing unit. Addressed thermostat filter change reminder issue by adjusting settings to disable recurring prompt after customer had already replaced filter. Performed full system inspection including checking refrigerant levels, electrical connections, and airflow; confirmed all components operating within manufacturer specifications and system running as designed.
Completed annual cooling maintenance on Mitsubishi ductless mini-split system with one indoor head unit. Performed comprehensive inspection of unit components and identified buildup on blower assembly. Opened front panel to access internal components, removed and thoroughly cleaned blower wheels to restore optimal airflow and system efficiency. Verified filter condition and overall unit operation upon completion with no concerns noted.
Completed annual AC tune-up on 2-year-old system located behind residence. Addressed customer concern regarding insufficient airflow to second floor by adjusting supply-side damper in basement to increase air distribution to upper level. Performed comprehensive system inspection, confirmed all components operating within normal parameters, and conducted duct cleaning to optimize system performance.
Performed comprehensive A/C maintenance on single condenser unit with R-410A refrigerant in 65-degree ambient conditions. Inspection included filter, thermostat operation, temperature differential, condenser coil condition, motors, capacitors, compressor function, refrigerant charge level, and condensate drain system. System found to be low on refrigerant charge indicating potential leak in refrigeration circuit. Presented repair options for refrigerant leak and recharge, which homeowner declined. Comfort advisor consultation scheduled for system replacement evaluation.
Responded to kitchen sink plumbing issue following remodel conversion from double bowl to single bowl sink. Successfully installed and connected tubular drain assembly with P-trap configuration to existing garbage disposal unit, restoring proper drainage function to the kitchen sink system.