We’ve assisted homeowners for over 65 years and will proudly service your home as well.

The weather in Mendota Heights tends to be chilly for much of the year. Heavy snowfall creates ideal conditions for skiing at places like Afton Alps or Welch Village. The freezing temperatures also make for great ice fishing at Rogers Lake. However, this cold weather can pose a challenge to homeowners. You’ll need a dependable heating system to keep your property warm and cozy during the winter. With our help, you’ll be able to heat your home without worrying about utility expenses going through the roof.
Turn To Our Heating Services For Great Results
- Heating repair: Problems like a malfunctioning heat exchanger or a failing blower motor make the heater use more energy, wearing out its parts faster. We can address these problems and others, like ignition failures, uneven heating, or strange noises coming from the system.
- Heating installation: We’ll help you select the best heating system for your house based on factors like its square footage, insulation quality, and existing ductwork. We can also assess your property for a heat pump. A heat pump is a great idea for many homes because it can reverse itself during the summer to provide cooling.
- Heating maintenance: One of the easiest ways to help your heater perform better is to sign up for our Hurlburt Family Rewards Program. We’ll clean the whole system and add lubrication to its moving parts once a year so it achieves peak efficiency at all times.
- Indoor air quality
Your cooling system greatly affects your sleep quality and overall health during the warm weather seasons. We offer services that fix issues like refrigerant leaks so your home stays cool, even when it gets really hot. With our installation help, you can be certain that your property will have the best AC right from the start. It will be much easier to unwind and rest since your home will be cool and comfortable. Plus, you won’t have to worry about the AC constantly breaking down. This gives you more energy and time to check out some of Mendota Heights’ best attractions, like Mendakota Park and Friendly Marsh Park.
We Provide a Wide Range of Trusted Cooling Services
- Cooling repair: Don’t let a failing compressor or clogged condensate drain line impact your home’s cooling. Our experts offer repairs to fix these issues and many others.
- Cooling installation: The wrong size AC can cause major problems, like inefficient cooling or excessive energy consumption. Need help choosing the right model? We’ll consider many factors to ensure you get the right size and type of cooling system for your house.
- Cooling maintenance: It’s easy to boost the performance of your AC with our maintenance. We even offer the Hurlburt Family Rewards Program to provide exclusive discounts and priority service.
See all of our HVAC services in Mendota Heights.
Water leaks and pipe corrosion can cause major damage to your home, affecting its foundation, walls, and structural integrity. Leaks can also harm your health by promoting mold growth. The plumbers at Hurlburt know how to find hidden leaks to prevent costly water damage. We even provide emergency plumbing for leaks and plumbing problems that cause flooding. Our water treatment solutions will improve your home’s water quality and help prolong your plumbing system’s lifespan.
See all of our plumbing services in Mendota Heights.
There are so many ways a Hurlburt electrician can make your home more efficient, safe, and convenient. We can add smart outlets so you can easily control appliances with your smartphone. Installing smart lights is a great way to enhance security and customize the brightness in each room. Our team also handles lighting installations for decorative, outdoor, and under-cabinet fixtures. Want to ensure your house will have power during a power outage in the Twin Cities area? We can install a dependable whole-home backup generator.
Our professionals service all of Mendota Heights and its many neighborhoods. We want you to have a home where you enjoy spending time and relaxing. Our plumbing, electrical, and HVAC services help homeowners just like you create optimal living spaces with the latest amenities.
We want to welcome you to the Hurlburt Family! Our team always strives to exceed customer expectations. That’s why we’ve received more than 6,000 5-star reviews. Our commitment to making the local community a better place to live drives us to deliver exceptional service every day.
Access the most honest and dependable plumbing, electrical, and HVAC company in Mendota Heights by calling Hurlburt now.
Hurlburt Heating & Plumbing has completed 20 jobs in Mendota Heights, MN between July 2026 and November 2026.
The most recent job was on November 13, 2026.
Hurlburt Heating & Plumbing has completed 51 jobs in Mendota Heights, MN in the last 12 months. The first job there was in October 2025.
Diagnosed a no-heat condition on a Crown boiler stuck in standby, with no response to a thermostat call or a jumpered T-T circuit; the unit attempted to start and then shut down. Traced the fault to defective control wiring at the boiler control board and gas valve, then replaced the faulty wiring and restored proper operation.
Responded to a no-heat call on a 10+ year old gas furnace. Found the Honeywell thermostat running on its schedule program, which was dropping the setpoint to 68°F, so the thermostat was set to Hold to maintain the desired temperature. Also removed and cleaned the flame rod to restore reliable flame sensing, then verified normal ignition and heating operation with a measured temperature rise of 64°F.
Performed a seasonal tune-up on two gas furnaces, each over 15 years old, including inspection of the gas valve assembly, burner area, wiring connections, and blower motor with electrical testing of components. Found dirty air filters restricting airflow and replaced them to restore proper system airflow and efficiency. Noted general dust accumulation and light corrosion on gas pipe fittings, with systems operating normally at completion.
Performed annual fall heating inspection on a slant fin boiler, verifying piping integrity with no leaks and confirming proper operation of the backflow preventer, pressure relief valve, expansion tank, circulator pump, heat exchanger, and burners, with a satisfactory combustion analysis and system pressure. Detected 1-2 ppm of CO emanating from the lower heat exchanger seal, which is below shutdown thresholds, and recommend monitoring this condition during future visits.
Performed a full tune-up and inspection on an 11-year-old Bryant condensing furnace. The control board, flame sensor, gas valve, and blower motor tested good, and the combustion analysis and temperature rise were within specification. Found the hot surface igniter near failure with extremely high resistance, the draft inducer motor drawing above its rated amperage with an intermittent rattle, condensate leaking from the exhaust piping down into the furnace, and heat exchanger showing signs of thermal stress. Reviewed all findings and repair options and scheduled a follow-up with a service advisor.
Completed annual heating maintenance visit on a 10-year-old Bryant furnace and gas fireplace as part of recurring preventive maintenance agreement. Performed comprehensive tune-up including verification of gas pressure within specifications, carbon monoxide testing in flue with safe readings confirmed, and visual inspection of heat exchanger showing no signs of deterioration or cracking. Cleaned flame sensor to ensure proper ignition reliability, inspected air filter finding it in acceptable condition, and tested all system components including gas valve assembly, blower motor, ignition system, and burner operation confirming all equipment operating within manufacturer specifications. System left in fully operational condition with all safety controls functioning properly.
Completed annual maintenance agreement service on Lennox furnace and high-efficiency boiler, both approximately one year old. Performed comprehensive tune-up on furnace including cleaning flame rod, testing HSI ohms, and measuring inducer and blower motor amperage—all readings within specification. Conducted test mode on S30 thermostat for first and second stage heating cycles. Measured combustion analysis with CO reading at 15ppm using Testo 310 II analyzer. Verified furnace heating operation satisfactory. Performed maintenance on high-efficiency boiler including cleaning flame rod and clearing drain trap. Tested igniter glow and flame ignition sequence—both operating properly. Measured boiler combustion with CO reading at 7ppm. Confirmed boiler heating operation normal. Property also equipped with Honeywell steam humidifier. All systems tested and operating within manufacturer specifications.
Completed seasonal inspection on 20-year-old residential boiler system as part of maintenance agreement. Performed comprehensive operational check of boiler unit, verified all safety controls, inspected gas connections and venting system, and confirmed proper heating operation. System found to be functioning within normal parameters with no deficiencies noted at time of service.
Responded to water leak concern at residential property. Upon inspection, found oxidized copper piping at the first few joints connecting to the main water supply line. Previous repairs had been attempted using electrical tape, which is not an appropriate method for plumbing applications. Confirmed no active leaking was present at time of inspection; visible oxidation on copper pipes indicated aging and deterioration of the water supply connections. Documented existing plumbing configuration showing exposed copper, PVC, and black piping running through floor joists with various fittings and connections. Provided detailed estimate to customer for cutting out deteriorated sections and replacing old copper piping with new materials to prevent future leaks and ensure system integrity.
Completed scheduled maintenance visit on two residential gas furnaces as part of recurring heating system agreement. Performed comprehensive tune-up on 16-17 year old single-stage unit including filter replacement, and conducted preventive maintenance inspection on 14 year old two-stage furnace. Inspected control boards, wiring connections, and all internal components to ensure proper operation for the heating season.
Completed scheduled heating maintenance tune-up on residential HVAC system. Performed routine system inspection and maintenance procedures, replaced dirty air filter with new filter, and verified proper operation of furnace components. All manufacturer specifications and safety labels were documented, and system is operating within normal parameters.
Completed comprehensive maintenance on Daikin heat pump system including rinsing outdoor coils, flushing condensation drain line in crawl space attic, and inspecting blower assembly. Verified system performance with supply temperature at 92°F and return at 73°F, achieving optimal 18-degree delta-T. Air filter replacement recommended. Additionally inspected Navien high-efficiency water heater/boiler and identified critically elevated carbon monoxide levels at 1200 ppm. Consulted with Navien technical support, followed diagnostic checklist, and successfully reduced CO levels to safe operating range of 78 ppm. Both heating systems tested and confirmed operational for winter season.
Completed comprehensive furnace and air conditioning tune-up on 6-year-old system. Addressed water pooling issue on basement floor caused by kinked condensate drain line from AC evaporator coil; straightened drain line to restore proper drainage and prevent overflow from drain pan. Performed full furnace inspection including blower assembly, heat exchanger, and safety controls; verified all components operating within manufacturer specifications and confirmed safe carbon monoxide levels in flue exhaust. Conducted air conditioning system evaluation including refrigerant charge verification, electrical component testing, and airflow measurements; all parameters within acceptable ranges. Cleaned debris and buildup from outdoor condenser coils to restore optimal heat transfer efficiency. Both heating and cooling systems tested and confirmed fully operational.
Completed annual preventative maintenance agreement covering both cooling and heating systems. Performed comprehensive inspection and maintenance on one air conditioning unit and one boiler system. All equipment was found to be operating within normal parameters with no deficiencies noted. Photographically documented interior cabinet condition of air handler showing condensate pump assembly, drainage lines, and insulation integrity, as well as electrical components including capacitor and terminal connections.
Completed annual cooling maintenance on one residential air conditioning system utilizing 410A refrigerant under Family Rewards membership agreement. Performed comprehensive inspection of indoor air handler including filter assessment, condensate drain verification, blower motor operation, and electrical wiring and component evaluation—all components found within normal operating parameters. Homeowner supplied filter for replacement during service visit. Verified temperature split across evaporator coil within acceptable range. Conducted thorough inspection of outdoor condensing unit including coil cleanliness assessment and capacitor condition check. Measured and recorded amperage draw on condenser fan motor, compressor, and contactor—all readings within manufacturer specifications. Verified refrigerant charge level appropriate for ambient temperature of 81 degrees. System demonstrated proper cooling cycle operation with Lennox smart thermostat displaying 74 degrees indoor temperature
Responded to no cooling complaint on 10-year-old Lennox air conditioning system. Upon inspection, discovered system was significantly low on refrigerant charge, indicating an active leak in the system. Verified proper airflow through evaporator coil and confirmed air filter was clean and unobstructed. Discussed leak detection and repair options with homeowner, including electronic leak search procedures and potential repair costs. Homeowner elected to schedule consultation with service advisor to evaluate replacement options rather than proceed with leak repair on existing unit. System remains non-operational pending customer decision on repair versus replacement.
Responded to no cooling complaint on Amana air conditioning system installed four years ago. Upon arrival, confirmed outdoor fan was running but unit not producing cool air. Inspected attic-mounted air handler and found it in acceptable condition. Replaced dirty air filter and proceeded to outdoor condenser unit for further diagnostics. Discovered condenser coils heavily clogged with cottonwood debris restricting airflow. Tested dual-run capacitor and found it reading 10/5 MFD against rated specification of 45/5 MFD, indicating significant capacitor degradation affecting compressor and fan motor operation. Advised customer of findings and recommended capacitor replacement and system cleaning to restore cooling function. Replaced failed dual-run capacitor with proper 45/5 MFD rated component. Thoroughly cleaned condenser coils to remove cottonwood accumulation and restore proper heat exchange. Performed complete system tune-up including all electrical connections and component inspect
Responded to multiple plumbing concerns including toilet leaks, kitchen sink faucet leak, and water hammer noise from washing machine supply lines. Replaced faulty fill valve on one toilet and tightened packing nut on leaking toilet valve to stop water seepage. Replaced leaking angle stop valve servicing upstairs bathroom fixture. Installed bidet attachment to existing toilet as requested. All repairs completed during single service visit to address immediate plumbing needs.
Responded to no cooling complaint on 2-year-old Lennox system. Upon arrival, thermostat was calling for cooling with indoor temperature at 78°F and setpoint at 73°F. Inspected indoor unit and found GFCI outlet tripped with red indicator light illuminated. Reset GFCI outlet and system powered on successfully. Verified system operation with delta-T reading of 20°F, indicating proper cooling performance. Cleaned and flushed condensation pump to ensure proper drainage. Noted air filter requires replacement and advised homeowner accordingly. Performed exterior inspection of condensing unit, confirming coils are clean, refrigerant lines properly insulated and cold to touch, and unit operating within normal parameters. System restored to full cooling operation and ready for summer season.
Responded to a non-flushing toilet issue. Upon inspection, determined the fill valve was malfunctioning and becoming stuck, preventing proper tank refilling. Removed the defective fill valve and installed a new replacement unit, restoring full functionality to the toilet's flush system.