Maple Grove is well-known for its bitter winters. The heavy snowfall makes for some great skiing at places like Elm Creek, and our freezing temperatures are ideal for ice skating at the arena. But to stay cozy at home without breaking the bank, you’ll need a heating system that operates efficiently. Our technicians provide repairs, installation, and maintenance for reliable heating all winter long.
Our Heating and Furnace Services Cover the Range:
- Heating repair: Is your heater acting strange? Our repair services restore your comfort and can lower your heating bills.
- Heating installation: Make sure you have the best heater for your house with our installation team. We offer energy-efficient heat pumps and more.
- Heating maintenance: Sign up for our Hurlburt Family Rewards Program to help your heater last longer and use less energy with expert maintenance. We will clean the whole system and make adjustments to achieve better energy efficiency.
Maple Grove offers lots of outdoor activities to enjoy the warm summer weather. You can go swimming at Weaver Lake, play tennis at Central Park, or picnic at Fish Lake. To stay comfortable at home, though, you’ll need a cooling system that doesn’t break down. That’s why we offer comprehensive cooling services.
Enjoy a Comfortable Home All Summer With:
- Cooling repair: Don’t let problems like refrigerant leaks or dirty filters affect your comfort at home. We can make cooling repairs to fix these problems and keep your AC working as it should all summer.
- Cooling installation: Achieve better cooling and lower your energy bills with an efficient AC installation. We consider multiple factors, like your home’s layout and square footage, to help you pick the perfect AC.
- Cooling maintenance: Boost the performance of your cooling system and ensure it lasts its full lifespan with regular maintenance. Check out our Hurlburt Family Rewards Program to save money and take the hassle out of keeping your AC running great.
- Indoor air quality
See all of our HVAC services in Maple Grove.
Plumbing systems can experience lots of problems that cause disruptions to your daily routine. A leaky water heater can make it impossible to enjoy a hot shower. A broken pipe can cause low water pressure, damaged walls, and water waste, which raises your bills. You can have our plumber from Hurlburt address these problems to protect your home.
See all of our plumbing services in Maple Grove.
You risk injuring yourself, damaging appliances, or starting a fire if you try to do electrical work yourself. Working on these systems requires great skill and knowledge. Our electricians have the experience, tools, and attention to detail to rewire your house, upgrade outlets, and much more. You can also upgrade your home in Maple Grove with new lighting that makes your property more beautiful, safe, and productive. Ask about recessed, decorative, under-cabinet, task, and outdoor lighting solutions. Our team can also install home generators and smoke detectors.
Our Electricians in Maple Grove Do It All:
- Electrical repair: Our professional repair services protect your home and family from electrical hazards. We can fix outdated outlets, damaged electric panels, faulty circuit breakers, and more.
- Electrical installation: Our electrical installations can make your home safer and more efficient while increasing its value. Ask about rewiring, adding outlets, upgrading panels, and installing generators. We can even add a home EV charger.
No matter where you live in Maple Grove, we want to help you create a home that you love spending time in. That way, you can feel rested and energetic to take in all that the city has to offer. Locals love hiking and biking the Rush Creek trails and paddleboarding at Rice Lake. But to keep their homes safe and comfortable after all the fun, they turn to us for all their HVAC, plumbing, and electrical needs.
Hurlburt is the plumbing, electrical, and HVAC company with a true passion for serving Maple Grove. We have thousands of 5-star reviews that show why homeowners hire us as their go-to home service provider. Our knowledge and industry experience are crucial, but what really sets us apart is delivering a warm, caring service that you’ll never forget. That’s why we exceed expectations on projects large and small.
If you want a home that’s energy-efficient, reliable, safe, and modern, you can count on us for top-tier HVAC, plumbing, and electrical solutions. As we’ve grown, we have stuck to our roots as a small-town business but have the skills and tools to deliver big-time results.
Contact Hurlburt now to schedule services with Maple Grove’s best electrical, plumbing, and HVAC company. Welcome to the Hurlburt Family!
Responded to no cooling condition caused by failed blower motor. Removed and replaced defective blower motor with premium PSC blower motor rated at 825/1075 RPM, single phase (28F01). Verified proper electrical connections to capacitor and control board, tested system operation, and confirmed restoration of airflow and cooling functionality.
Responded to dispatch for inadequate hot water supply from a 10-year-old gas water heater. Customer reported hot water lasting only 7-8 minutes during showers. Upon arrival, conducted diagnostic testing and measured output water temperature at 102°F after 56 minutes of continuous operation, confirming insufficient heating capacity. Determined that the existing gas unit required replacement due to failed heating components and age-related deterioration. Removed old gas water heater and installed new Rheem residential tank water heater with proper venting, supply lines, and code-compliant connections including PEX supply piping and appropriate shut-off valves. Verified proper operation and tested output temperature at fixture, confirming 103.5°F delivery temperature. System restored to full operational capacity with adequate hot water recovery rate for household demand.
Responded to water leak complaint at rental property where bathtub was leaking during use. Upon inspection, discovered missing gasket on the overflow assembly. Accessed plumbing from below through basement/utility area, confirmed leak source at tub overflow connection, and installed replacement gasket to restore proper seal and eliminate water infiltration.
Responded to no cooling call where outdoor unit was running but indoor blower was not operating. Upon inspection, discovered water in condensate pan had triggered safety float switch, shutting down indoor fan operation. Diagnosed failed blower motor as root cause of cooling system failure and completed motor replacement to restore full system functionality.
Replaced both primary and secondary heat exchangers on a Noritz tankless water heater under warranty. Installed new gaskets and washers per manufacturer specifications, reconnected all electrical wiring, and pressure-tested the system for five minutes with no leaks detected. Verified proper operation by running hot water through the unit, confirmed functionality, and returned the system to service.
Responded to no-cooling complaint on DIY-installed Mr. Cool mini-split heat pump system less than one year old. Upon inspection, discovered visible crack in pre-vacuumed copper line set causing refrigerant leak, with extensive corrosion and oxidation present on the damaged section. Documented damage with photos showing compromised line set integrity and scheduled follow-up appointment with advisor to discuss line set replacement and system recharge options.
Completed seasonal AC tune-up on a 9-year-old Lennox system that was operating properly upon arrival. Performed standard maintenance protocol including electrical testing at the outdoor unit using digital multimeter to verify proper voltage and amperage readings. Inspected exterior electrical connections and terminal blocks, noting weathered housing with minor surface corrosion but secure wire terminations. System tested and confirmed to be functioning within normal parameters with no deficiencies requiring immediate attention.
Responded to a multi-unit property for persistent water leak investigation following a previous repair attempt. Upon arrival, discovered water on the floor of Unit A, traced the source to a pinhole leak in the piping system after the water meter serving Unit B. Diagnosed that the initial repair had not resolved the underlying issue, as moisture continued to accumulate. Replaced the defective shut-off valve and 90-degree elbow fitting on the affected line to eliminate the leak source. The work was performed on aging galvanized piping with existing oxidation and corrosion present throughout the system. Verified proper installation of new components and confirmed no active leaking upon completion of valve and fitting replacement.
Responded to no cooling complaint on 14-year-old air conditioning system. Upon inspection, discovered burnt wiring at capacitor caused by hard start kit wires contacting high voltage power supply. Rewired electrical connections to capacitor and hard start kit, ensuring proper separation from high voltage components. Cleaned condenser coil to improve heat transfer efficiency. Performed refrigerant system diagnostics using manifold gauges, which revealed low subcooling readings indicating refrigerant leak in system. Based on service history showing previous recharge without leak repair and current age of equipment, recommended system replacement. Scheduled same-day estimate for new air conditioning installation.
Completed comprehensive AC tune-up and maintenance inspection on 6-year-old residential air conditioning system. Verified and tested all major components including thermostat operation, air filter condition, blower assembly, outdoor condensing unit, electrical connections, contactor, capacitor, and condensate drain system. Measured condenser fan amperage at 5.2 amps using clamp meter, confirmed refrigerant charge and performance levels, and verified temperature split across evaporator coil. All operational parameters and electrical readings measured within manufacturer specifications with no mechanical defects, safety hazards, or performance issues identified. Outdoor coil and condenser unit found in clean condition with proper airflow. System operating at optimal efficiency with no immediate service needs or repairs required.
Completed annual air conditioning tune-up and comprehensive maintenance inspection on residential cooling system. Performed thorough evaluation of all major components including thermostat operation, air filter condition, blower assembly, outdoor condenser coil, electrical connections, contactor, capacitor, condensate drain system, refrigerant charge levels, and temperature differential across the evaporator coil. All operational readings measured within manufacturer specifications with no mechanical defects or safety concerns identified. System verified to be operating at proper efficiency levels. Documented dust accumulation on return air grille and provided maintenance recommendations including regular filter replacement, periodic coil cleaning, and continued scheduled preventive maintenance to ensure optimal performance and system longevity.
Replaced compressor under full parts and labor warranty on 4-ton AC system. Charged system to proper specifications achieving 8 degrees subcooling and 21-degree temperature split. Corrected airflow setting from F4 to F2, increasing CFM from approximately 1000 to 1560 for proper tonnage match. Static pressure measured at 0.65"wc. Removed plugged 4" furnace filter and installed 1" temporary filter. Verified all three zone dampers operating correctly on command. Identified two older damper assemblies on main and second floor zones with history of intermittent failure; recommended replacement quote for these units. Recommended shutting down air exchanger during warmer weather. System operating within manufacturer specifications upon completion.
Responded to utility room for multiple water leaks affecting tankless water heater system and main water supply line. Upon inspection, identified corroded copper 90-degree fittings on cold water supply line causing active leak. Replaced damaged copper fittings and restored water service, pressure testing system to confirm successful repair. During secondary inspection of tankless unit, removed front access panel and discovered water accumulation around secondary heat exchanger with sporadic dripping. Consulted with Noritz technical support to diagnose heat exchanger failure. Coordinated replacement part order through manufacturer (Sales Order #812376-SO) for secondary heat exchanger component to be shipped directly to property for follow-up installation. System restored to temporary operation with main supply leak fully resolved.
Performed comprehensive AC tune-up on single-zone residential air conditioning system. Conducted thorough maintenance inspection including thermostat function verification, air filter condition assessment, blower assembly examination, outdoor coil inspection, electrical component testing, contactor and capacitor evaluation, condensate drain check, refrigerant performance analysis, and temperature split measurement. All system readings were within manufacturer specifications with no mechanical defects or safety concerns identified. System confirmed operating properly at time of service. Advised customer to maintain regular filter changes, keep indoor and outdoor coils clean, and schedule routine preventative maintenance to ensure optimal performance and longevity.
Installed customer-provided garbage disposal and kitchen faucet beneath kitchen sink. Connected braided stainless steel supply lines to angle stop valves with proper escutcheons at wall penetrations. Installed dishwasher supply line to existing water connection. Verified all connections for proper operation and checked for leaks. All fixtures tested and functioning correctly upon completion.
Completed annual cooling system maintenance visit on residential air conditioning unit. Performed comprehensive AC inspection confirming operational status of all components. Cleaned evaporator coil to ensure optimal heat transfer and system efficiency.
Responded to a sump pump system requiring code compliance for a home sale. The primary sump pump was operational, but the battery backup pump had never been properly connected and was improperly positioned in the basin. Disassembled both the primary pump and battery backup system, installed a new check valve to ensure proper flow direction and prevent backflow, and reassembled both pumps with correct positioning and electrical connections. The battery backup system is now fully functional and integrated with the primary pump, bringing the entire sump pump assembly up to code requirements.
Completed annual air conditioning tune-up on 10-year-old system. Performed comprehensive inspection and testing of all components, verified refrigerant charge levels within manufacturer specifications, and confirmed proper operation of all system functions. Identified worn contactor with pitted contacts and replaced with new unit to ensure reliable performance and prevent potential system failure.
Responded to service call for leaking water heater in basement utility area. Upon inspection, found 50-gallon electric Rheem Classic series water heater with visible corrosion and active leak originating from bottom of tank. Unit was approximately 3 years old and showed signs of internal tank failure with rust-through condition. Documented existing installation including copper supply lines, brass fittings, flexible gas connections, and orange PEX distribution piping. Noted water softener system and Logic filtration equipment in immediate vicinity of failed heater. Assessed plumbing configuration including pressure gauge, wall-mounted connections, and hot water return line. Provided estimates for complete water heater replacement due to irreparable tank corrosion and leak severity.
Replaced malfunctioning zone valve motor head that was stuck open, causing hot water to pass through the system during air conditioning operation. Upon installation of new motor head, discovered relay was also stuck open, causing improper zone motor operation during both heating and cooling calls. Corrected relay issue and verified proper system operation with all zones functioning correctly.