Recent Jobs and Reviews in Lake Hallie, WI
Job Locations and Reviews
Responded to no cooling complaint on 10-year-old air conditioning system. Upon arrival, found outdoor unit fan motor operating but compressor not running. Performed diagnostic inspection of electrical components and identified failed compressor capacitor reading approximately 4 microfarads instead of rated 30 microfarads. Replaced defective compressor capacitor with proper replacement. Tested system operation and confirmed compressor engaged properly. Measured temperature split of approximately 15 degrees across evaporator coil and verified refrigerant pressures within acceptable range. During inspection, observed contactor showing significant pitting on contact surfaces and condenser fan motor exhibiting stiffness during rotation, indicating these components are nearing end of service life. Advised customer of deteriorating condition of remaining electrical components and recommended obtaining replacement system pricing given the age of equipment and cumulative repair costs, as curren
Responded to basement water leak caused by pinhole leak in copper pipe upstream of sediment filter and pressure tank system. Replaced defective ball valve and repaired compromised copper piping to restore proper water flow and eliminate active leak. System tested and verified operational with no additional leaks detected.
Responded to water leak complaint affecting interior of home. Upon inspection, identified leak originating from irrigation line at the pressure vacuum breaker (PVB) assembly located on building exterior. Documented condition with photographs showing corroded piping and PVB components. Submitted parts order request to prepare replacement estimate for damaged irrigation system components.
Completed comprehensive plumbing inspection as part of recurring maintenance program. Inspected water heater and identified corrosion at base of unit with rust staining on surrounding concrete floor, indicating potential leak or age-related deterioration requiring monitoring. Documented all plumbing systems, HVAC ductwork, and utility infrastructure throughout mechanical spaces to ensure proper operation and identify any maintenance concerns.
Responded to service call for loud noise coming from furnace. Upon arrival, performed diagnostic inspection and discovered a piece of previous filter wrapper lodged in the blower wheel causing the noise complaint. Removed foreign material from blower assembly, restoring quiet operation. Additionally completed annual AC maintenance inspection, verifying evaporator coil and filter were clean, condensate pan draining properly, and all routine electrical components on outdoor unit within manufacturer specifications. Conducted operational test of complete system with 15-minute runtime, confirming 18-20 degree temperature drop across evaporator coil and proper system function. All equipment operating normally upon departure.
Responded to no cooling complaint with warm air blowing and minimal airflow. Upon arrival, diagnosed compressor clicking sound and identified failed capacitor as primary issue. Performed complete condenser coil cleaning, replaced defective capacitor, installed new air filter, and tested system operation to verify proper cooling restored.
# HVAC Maintenance Agreement Completed Performed comprehensive 12-point air conditioning tune-up on residential split system with Guardian furnace and outdoor condenser unit. Cleaned outdoor condenser equipment and coils, tested all electrical components for proper operation, and cleaned indoor evaporator drain line to ensure proper condensate removal. System evaluated and found to be cooling adequately, though operating near freezing threshold which will require monitoring. Captured detailed photographs of equipment including make, model, and serial number information for service records. Unit age uncertain; system appears to be functioning within acceptable parameters despite borderline temperature readings on evaporator coil.
Completed annual plumbing inspection on duplex unit. All plumbing systems and fixtures were found to be in proper working condition. Identified worn left basket strainer on kitchen sink and replaced it with new unit upon approval. Documented conditions with photographs for service records.
Completed annual AC maintenance tune-up on residential air conditioning system as part of membership agreement. During inspection, discovered one speed connector had disconnected from the capacitor and successfully reconnected it. Identified condenser fan blade wobble and noted unusual ductwork configuration throughout the home. Requested quote for replacement condenser fan blade to address the wobble issue and ensure optimal system performance.
Completed FRP plumbing inspection of residential property, examining newly installed PVC piping system with proper connections and securing mechanisms within wood-framed structure, and verified functionality of bathroom sink fixture with chrome faucet. Documentation and inspection sheet completed with supporting photographic evidence of all plumbing components.
Responded to no-heat service call for Lennox furnace displaying E250 error code (primary limit switch open). Diagnosed completely plugged air filter as source of issue. Replaced filter, reset equipment, and monitored system operation for approximately 20 minutes until proper heating function was restored. Customer expressed interest in whole-home humidifier installation; provided information as requested.
Responded to service call for non-functional sump pump affecting downstairs fixtures. Diagnosed issue as a stuck float mechanism. Resolved problem by connecting hose and thoroughly cleaning the float assembly, restoring proper pump operation.
Responded to no heat call for 20+ year old Amana system. Inspection revealed multiple cracks and holes in the heat exchanger, which was confirmed by visible corrosion and deterioration around pipe connections. Due to safety concerns, system was shut down and emergency service scheduled for 8am following day. Owner was present during diagnosis and was shown the damaged components.
Diagnosed and replaced damaged internal toilet components. Removed tank lid to access and replace broken fitting and malfunctioning flush mechanism. Installation included new toilet "guts" to restore proper operation.
Performed comprehensive furnace tune-up on 8-year-old primary residential unit and garage hanging unit. Replaced humidifier pad, checked all electrical components, cleared condensate lines, and inspected heat exchangers—noting stress on garage unit's heat exchanger back bends but no compromises requiring immediate attention. Both systems tested for proper operation with primary unit showing appropriate temperature rise of 55 degrees and gas pressures within specification.
Conducted furnace tune-up on 8-year-old FR furnace system. Replaced humidifier pad, verified all electrical components within specification, cleared condensate lines, and inspected heat exchanger (no compromises found). Also serviced hanging unit in garage, noting stress on heat exchanger back bends but no operational issues. Both systems demonstrated proper operation with appropriate temperature rise and gas pressures during extended testing.
Performed scheduled furnace maintenance including comprehensive inspection, operational checks, and air filter replacement. Examined existing humidifier which is functioning properly. All HVAC components are operating within normal parameters with no issues identified.
Performed furnace maintenance tune-up on an Amana system. Identified heavily clogged MERV 14 filter restricting airflow; adjusted high/low fire settings and verified proper temperature operation. Recommended switching to MERV 8 filters with replacement 2-3 times monthly to improve system performance and airflow. Noted homeowner's concern about cooling season performance issues to be addressed during next seasonal maintenance visit.
Performed semi-annual maintenance on a furnace as per agreement. Replaced dirty filter, cleaned and balanced blower, and inspected heat exchanger which showed normal hotspots on first back bends with no compromises. All electrical components tested within specifications, trap was clean with clear lines, and system demonstrated proper operation with appropriate gas pressures and 50-degree temperature rise during 15-minute operational test.
Includes: -Gas Line and Fittings -Gas Manifold -Vent Kit -Honeywell Digital Programmable Thermostat -Installation
Colton C. was very professional, answered my questions and explained what I need and what he did. Great to be a Hurlburt customer!!
Hi Gary, thank you so much for leaving a 5-star review for Hurlburt Heating & Plumbing! It's feedback like yours that gets us excited to continue providing top-notch service to our customers. We're so glad that Colton was able to assist you with professionalism and answer your questions. We appreciate you being a loyal Hurlburt customer!
Went out to a home to fix a plumbing issue. I carefully inspected the toilet in the guest bathroom and found that the flapper was not sealing properly, causing the water to leak. Once the flapper was replaced, I tested the toilet to ensure everything was working properly and there were no leaks.
Went out to assist a customer who was experiencing issues with their heating system. The furnace was not producing enough heat, and the thermostat was not working properly. I replaced the faulty parts and tested the furnace to ensure it was working properly again for the home.
Plumbing Repair: Responding promptly to a client's urgent plumbing concerns, our seasoned team adeptly addressed a leaking pipe. Conducting a thorough diagnosis to precisely identify the leak's source, we replaced the damaged section and performed a comprehensive check. This guaranteed a durable, leak-free solution, ensuring the overall integrity of the plumbing system.
Working on Goodman Air Conditioner