We’ve assisted homeowners for over 65 years and will proudly service your home as well.

Lake Elmo is a great place to enjoy outdoor winter activities like sledding at Lake Elmo Park Reserve or ice fishing at Lake Elmo. At home, however, you’ll want to have a fully functional heating system. Our heating services keep your home warm and cozy during the coldest weather. We can even fine-tune your heater to help it perform better and save you money.
Our Heating Services Keep You Warm Through the Winter
- Heating Repair: We take care of everything from uneven heating to strange furnace noises to complete system breakdowns.
- Heating Installation: Get the best heating setup for your house with our expert installation services. We install furnaces, heat pumps, and more.
- Heating Maintenance: Join our Hurlburt Family Rewards Program to receive a comprehensive safety inspection and one furnace tune-up each year. Another benefit is that your membership fees can be applied toward the cost of a full furnace replacement.
Lake Elmo has some pretty warm weather throughout the summer, and a lot of residents beat the heat by swimming in the chlorinated swim pond at the Lake Elmo Park Reserve. You can also stay comfortable at home with our cooling services. We can make adjustments to ensure your AC helps with proper humidity control to ward off mold issues. With regular maintenance, your cooling system will use less energy, which means lower bills.
Create a Comfortable, Efficient Home with Our Cooling Services
- Cooling Repair: Cooling systems can experience a lot of problems, including refrigerant leaks, dirty air filters, or failing compressors. We know how to address all of these problems to keep your home cool all summer long.
- Cooling Installation: Use our installation support to guarantee you have the right cooling system for your home. You’ll save money and be more comfortable.
- Cooling Maintenance: Access the Hurlburt Family Rewards Program for annual maintenance that helps your AC last longer. You’ll get select discounts and perks, too!
- Indoor air quality
See all of our HVAC services in Lake Elmo.
Your home’s plumbing affects everything from bathing to washing clothes, doing dishes, and much more. Even small leaks can cause major inconveniences and costly water damage. We know how to find even hidden leaks. We also work on sump pumps and water heaters and offer water treatment solutions. When you need a reliable plumber, you’ll be happy you chose Hurlburt.
See all of our plumbing services in Lake Elmo.
Electrical systems are dangerous to work on and present hazards like electrical shock, fires, and equipment damage. This is why we never recommend trying to do any type of electrical repair or installation yourself. Our electricians have many years of experience working on electrical systems. We do full rewiring, panel replacements, and much more. If you have an electric vehicle, we can install a Level 2 EV charger in your garage or driveway.
Electrical Services to Keep Your Home Powered
- Electrical Repair: Are you experiencing issues with tripped circuit breakers or buzzing sounds coming from the outlets? Our electricians deliver the best repairs possible to keep your home safe and fully functional at all times.
- Electrical Installation: There are many processes involved in electrical installations that require expert-level skills and knowledge. Our electricians have the expertise to handle complex wiring while also ensuring compliance with all applicable codes.
Lake Elmo has so much to offer to its residents. You can spend the day picnicking at Lake Elmo Park Reserve, fishing at Sunfish Lake Park, or relaxing at Richard Walton Memorial Park. The Lake Elmo Inn Event Center has a banquet hall where you can celebrate special occasions like weddings or anniversaries. When you return home, it’s crucial to have effective indoor climate control and functioning plumbing and electricity. That’s why we offer the best home services throughout the area.
Hurlburt is one of the most trusted home service companies in Lake Elmo. We have over 6,000 5-star reviews that you can read to see why so many homeowners have turned to us since we first opened our doors in 1959. Our 65+ years of experience ensure that you will receive the best HVAC, plumbing, and electrical work possible. The level of service that we offer sets us apart from other home service companies in the area. We always aim to provide a world-class experience for every customer.
Contact Hurlburt today to access the best HVAC company in all of Lake Elmo. We can also help with all of your plumbing and electrical needs.
Hurlburt Heating & Plumbing has completed 20 jobs in Lake Elmo, MN between August 2026 and September 2026.
The most recent job was on September 25, 2026.
Completed comprehensive pre-winter maintenance on a 6-year-old Daikin furnace system. Performed full tune-up including flushing the condensation drain, cleaning the flame sensor, and conducting thorough inspection of heat exchanger, inducer motor, and blower motor—all components found in good working condition. Tested carbon monoxide levels at 16 ppm, which is within safe operating parameters. Verified air filter condition, confirmed proper operation of 2-zone motor system, and inspected ductwork with no abnormal sounds detected. Measured gas pressure at -0.45" W.C. and static pressure at 0.33" W.C. using dual port manometer to ensure optimal system performance. Despite initial customer concern regarding persistent ticking noise, no abnormal sounds were present during inspection. System tested, tuned, and confirmed ready for heating season.
Responded to call back on newly installed garage heater where gas line pressure had dropped from 30 psi at initial installation to 20 psi. Performed comprehensive leak detection using gas probe on all joints and connections throughout the gas line system with no leaks detected. Opened gas line from meter, started garage heater unit, and verified proper operation and heating function. System tested and confirmed operational with all safety protocols observed.
Completed comprehensive seasonal tune-up on 8-year-old American Standard HVAC system including both furnace and air conditioning components. Performed thorough inspection of furnace revealing heat exchanger clean and free of rust or cracks, cleaned flame rod, verified blower motor and inducer motor amp draws within specifications, confirmed hot surface igniter ohm reading within acceptable range, and measured carbon monoxide at safe level of 7ppm. Identified inducer capacitor reading slightly below manufacturer specifications and replaced with new capacitor to ensure optimal performance. Inspected air conditioning system including component box, confirmed outdoor coils clean and free of debris, verified all wiring intact without damage, tested capacitor and contactor with readings within normal range, and measured temperature differential at 18 degrees indicating proper refrigerant charge and system operation. Both heating and cooling systems operating efficiently with all components f
Completed comprehensive maintenance tune-up on high-efficiency Lennox furnace per maintenance agreement. Performed full system inspection including verification of air filter condition, temperature splits, gas pressure readings, electrical connections, and combustion safety. Cleaned flame sensor and inspected igniter to ensure reliable ignition and combustion performance. Inspected humidifier pad and housing assembly, confirming proper installation and condition. All safety checks passed, system operating efficiently with no deficiencies identified.
Completed comprehensive plumbing inspection including hot water heater maintenance and full system evaluation. Performed complete flush of Rheem water heater unit (manufactured 08/2022) to remove sediment buildup and ensure optimal performance. Conducted thorough inspection of all visible plumbing components including water heater connections, copper piping, PEX lines, brass valves, and circulation pump assembly. All plumbing systems found to be in good working condition with no leaks, corrosion, or operational concerns identified. Recommended adding one bag of salt to water softener to maintain proper water treatment system function and prevent hard water issues.
Responded to service call for automated kitchen faucet with solenoid failure causing operational issues. Diagnosed faulty solenoid component and assisted customer in sourcing replacement parts through manufacturer warranty. Addressed leaking faucet concern in bathroom during visit and documented existing fixtures for reference.
Completed HVAC installation callback to address gas line routing issues. Installed 4-inch stainless steel tee and applied gas line lubricant to establish proper gas connection to exterior meter assembly. Performed pressure test with gauge to verify system integrity and confirmed all connections are gas-tight and meet code requirements.
Completed comprehensive plumbing inspection of residential property including basement mechanical room and bathroom facilities. Inspected water treatment system consisting of green filtration tank and black brine tank, verified proper operation of water softener controls and PEX manifold distribution system, examined water heater connections and supply lines for leaks or corrosion, and assessed all visible plumbing infrastructure in utility area. Evaluated bathroom plumbing fixtures including toilet with bidet attachment, vanity connections, and shower/tub assembly to ensure proper function and identify any potential issues requiring attention.
Completed comprehensive furnace tune-up inspection on residential heating system. Performed full diagnostic evaluation including thermostat operation, air filter condition, blower assembly, burner and heat exchanger compartment, inducer operation, ignition system, flame sensor, safety controls, electrical components, condensate drain, and temperature rise measurements. Utilized dual port manometer to verify gas pressure readings, which measured within manufacturer specifications at 350 and 358 on digital display. All system components found operating within normal parameters with no mechanical deficiencies or safety concerns identified. Documented equipment make, model, and serial number information with photographs. System verified to be functioning properly and safely at time of inspection.
Installed LF25 gas unit heater in residential garage with wall mounting. Ran flexible gas line up to 10 feet from supply point to heater location, incorporating two gas fittings for proper connection. Performed complete leak check on all gas connections and fittings to ensure safe operation and code compliance.
Completed comprehensive heating maintenance tune-up on 11-year-old Daikin gas furnace system. Performed full system inspection including flame sensor cleaning, heat exchanger examination, burner assembly check, and safety control verification. System tested and confirmed operating safely with proper combustion and airflow parameters.
Responded to service call for corroded water supply line preventing washing machine installation. Replaced deteriorated water line feeding the washer connection, as appliance installers required updated plumbing before proceeding with equipment installation. Although the existing shut-off valves showed corrosion on exterior surfaces, they remained fully operational and did not require replacement. Completed the water line installation and successfully installed the washing machine, which had been staged outside the laundry room. All connections tested and verified leak-free with proper water flow to the appliance.
Responded to service call for AC control board replacement under parts and labor warranty. Upon diagnostic inspection of the unit's control system and circuit boards, determined the issue was related to a faulty sensor rather than the control boards themselves. Identified the specific sensor requiring replacement and ordered the necessary part for return visit to complete the repair.
Responded to no cooling complaint on Mitsubishi Electric mini-split system installed 6 months prior. Upon arrival, outdoor unit was not running despite indoor unit powering on. System restored to full operation after homeowner cycled power at breaker while describing issue to technician. Consulted with technical support who confirmed unit likely entered fault state following power outage from backup generator cycling. Advised homeowner to cycle power at breaker panel if issue recurs. Inspected Aprilaire whole-home dehumidifier per homeowner concern regarding door sticking and humidity control. Verified dehumidifier operating within normal parameters but noted current duct configuration requires HVAC system blower operation for proper air circulation and dehumidification effectiveness. Documented equipment with photographs of outdoor condenser unit and dehumidifier control panel showing model and serial number information for service records.
Completed comprehensive plumbing inspection of residential water heating and treatment systems. Performed maintenance flush on wall-mounted tankless water heater unit per homeowner request, removing mineral buildup and sediment to maintain optimal efficiency and extend equipment lifespan. Inspected associated plumbing connections including PEX supply lines, PVC venting system, and all mechanical components for proper operation. Verified water softener system with digital control head and brine tank functioning correctly. All equipment found in good working condition following service completion.
Responded to no cooling call following power outage on one-year-old system. Upon arrival, verified thermostat settings, air handler operation, and filter condition—all satisfactory. Inspected outdoor unit and confirmed contactor engagement with proper 240V and 24V supply. Retrieved error code E414 from AC control board indicating High Discharge Line Temperature Fault. Noted outdoor coil had accumulated dirt and debris. Performed hard reset and successfully restarted system on cooling mode. Verified refrigerant pressures within normal operating range and temperature split acceptable despite dirty coil condition. Cleaned outdoor coil with water rinse to improve heat transfer efficiency. Cycled system multiple times for testing; E414 fault code returned consistently. Consulted with technical support to confirm diagnosis of faulty control board causing false high temperature reading. System operates temporarily after reset but fault recurs, indicating electronic failure rather than mechani
Completed full HVAC system replacement including installation of Lennox EL297V 97% AFUE two-stage multi-speed upflow furnace (135K BTU), EL18KCV 18.0 SEER2 single-stage 5-ton air conditioner, and 5-ton D-frame cased coil with factory-installed TXV valve. Replaced existing thermostat with Lennox S40 programmable unit. Reused existing outdoor disconnect and whip where applicable. During inspection, identified electrical code deficiencies requiring new whip and breaker installation for proper AC connection. Coordinated with electrician to install compliant electrical whip and dedicated breaker to meet current electrical code requirements. Leveled outdoor condenser unit to manufacturer specifications. All equipment installed to code, system tested and operational.
Responded to a furnace service call for a recurring blown fuse issue on the control board. Upon inspection, discovered the high limit switch was improperly secured with only one mounting screw, causing it to tilt and make contact with the heat exchanger metal, which created a ground fault and repeatedly blew the fuse. Removed high voltage wiring and systematically tested the inducer motor, gas valve, and safety switches to isolate the problem. Replaced the blown fuse, properly secured the high limit switch with correct mounting hardware, and verified all wiring connections. Cycled the system through heating, cooling, and fan-only modes to confirm normal operation across all functions.
Responded to a non-operational outdoor condensing unit and diagnosed a failed condenser fan motor. Replaced the defective PSC motor (825/1075 RPM) with a new standard unit, restoring proper airflow and system operation. Verified unit functionality upon completion with all components running within normal parameters.
Responded to no-cool complaint on 14-year-old residential central air conditioning system. Diagnosed failing condenser fan motor preventing proper unit operation. Submitted parts order for replacement condenser fan motor and scheduled follow-up appointment for installation upon part arrival.