We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Minnesota is known for its cold winter weather, and the average high temperatures in Hopkins are well below freezing from December through February. When the cold hits, you can count on our heating experts to make sure your family keeps warm. Our technicians can take care of your furnace, boiler, or heat pump, ensuring it’s correctly maintained and deftly handling any repairs. If you’re struggling with a cold house, we won’t rest until it’s fully warm again. We can also help you enjoy greater comfort by upgrading your house with a new, high-efficiency heating system.
We’re Ready to Assist With Heating Services:
- Heating Repair: Even minor problems can put your heating at risk of giving out suddenly or shortening its lifespan. That’s why you should look to us for prompt heating repairs.
- Heating Installation: Tired of your heating bills rising year after year? Don’t wait until it’s too late! Contact us to get the new system you need.
- Heating Maintenance: Our reliable maintenance services are a great way to save on your energy bills and get the most out of your heating. With the Hurlburt Family Rewards Program, you’ll get discounted repairs and save even more!
Looking for ways to stay cool this summer without breaking the bank? Our service technicians can expertly maintain and repair your AC so it always works efficiently during our often hot and humid weather. We understand how frustrating and stressful it can be when your home is constantly too hot. We offer top-notch ACs, heat pumps, and mini-splits and will help you find the ideal new cooling system for your home.
Depend on Us for These Cooling Services:
- Cooling Repair: If your AC seemingly never shuts off or causes your electricity bill to spike, we can get it fixed straight away. We work on all brands and all types of cooling equipment and can handle any problem.
- Cooling Installation: If you live in an old home without ductwork, a mini-split AC system is the perfect solution to keep you cool. Have an old AC or heat pump that no longer works well? Ditch it and beat the heat with a new central cooling system from Hurlburt.
- Cooling Maintenance: Don’t struggle with frequent breakdowns and subpar energy efficiency. Our maintenance experts will keep your AC in peak condition. Experience the highest level of service and support with the Hurlburt Family Rewards Program!
See all of our HVAC services in Hopkins.
The worst thing you can do when it comes to your plumbing is neglecting issues that need to be fixed. Even a seemingly minor thing like a dripping faucet can cost you greatly due to the amount of water it wastes. No repair is too big or too small for our experienced plumbers to handle. Whether it’s insufficient hot water or a slab leak, we’ll help you overcome it. As one of the most experienced plumbing companies in the area, you can rely on us for professional installations and upgrades as well.
See all of our plumbing services in Hopkins.
Want to make 100% certain your electrical system is safe? Our team can identify any electrical hazards in your home and make sure they’re fully eliminated. Whether it’s smoke coming from an outlet or a switch that feels hot, count on us for rapid, reliable assistance. Upgrading your home with a new electrical panel is a great way to save on electricity costs. We can also keep you prepared for power outages with a backup generator and perform any other installation.
How Our Electricians Can Help You:
- Electrical Repair: We take pride in performing quality electrical repairs and improving electrical safety. From dead outlets and flickering lighting to malfunctioning circuit breakers, we’ll fix whatever problems your home has.
- Electrical Installation: Do you have an EV and are sick of slow charging speeds? Let us help by installing a new Level 2 charging station. We’re adept at installing all other types of electrical equipment and components and are ready to put our skills to work for you.
No matter if your house is near ArtStreet, the Pavilion, or the Artery, we’re ready to serve you. With more than 450 houses that are 100+ years old, Hopkins has a whole lot of historical charm. Whether you live in one of these homes or something newer, we can meet your needs while treating your house with the care and respect it deserves.
For more than 65 years, Hurlburt has been cultivating long-lasting partnerships with area homeowners by offering them honest advice and unbeatable service and support. The thousands of five-star reviews we’ve received are a testament to the quality of work we perform. We also believe in giving back however we can as a way to say thanks to our community.
For assistance from a dependable, trustworthy plumbing, electrical, and HVAC company, contact Hurlburt in Hopkins today!
Completed comprehensive air conditioning maintenance inspection per family rewards agreement. Verified and tested all major system components including thermostat operation, air filter condition, blower assembly, outdoor coil cleanliness, electrical connections, contactor, capacitor, condensate drain line, and refrigerant charge levels. Measured temperature split across evaporator coil and confirmed all readings within manufacturer specifications. System operating properly with no mechanical defects or safety concerns identified at time of inspection.
Completed annual cooling system maintenance and tune-up on Daikin HVAC system. Performed comprehensive inspection including thermostat calibration, air filter evaluation, blower assembly examination, outdoor coil assessment, electrical component testing, contactor and capacitor verification, condensate drain check, refrigerant charge analysis, and temperature split measurements. Investigated noise concern reported by neighbor regarding outdoor unit operation. All system parameters measured within manufacturer specifications with no mechanical defects, refrigerant issues, or safety hazards identified. System confirmed operating efficiently and properly. Recommended continued regular filter replacement and coil maintenance to ensure optimal performance and system longevity.
Completed biannual preventative maintenance plumbing inspection of residential property. Performed comprehensive assessment of all accessible plumbing fixtures and water heating equipment. Inspected Bradford White natural gas water heater, model RG1PV50S6N19, with 50-gallon capacity and 40,000 BTU input rating. Verified proper operation, checked for leaks, and confirmed all safety labels and operational instructions were intact and legible. Examined bathroom plumbing fixtures including toilet, observing proper flush operation and checking for leaks at tank connections and base seal. All fixtures found to be functioning within normal parameters with no signs of water damage, corrosion, or operational deficiencies. No repairs required at this time. System operating as designed with no issues identified during inspection.
Completed comprehensive tune-up and maintenance on both furnace and air conditioning systems. The furnace exhibited heavy dust accumulation due to recent construction activity. Cleaned and dusted burners, scrubbed flame sensor, inspected heat exchanger for cracks or damage, and replaced air filter. Tested carbon monoxide levels which measured 23 ppm, within acceptable safety range. Verified condensation drain line is clear and draining properly. Performed exterior AC unit maintenance including coil rinse-down to remove debris and improve heat transfer efficiency. Inspected and tested capacitor for proper microfarad rating, examined contactor for pitting or wear, verified all electrical connections are secure, and checked refrigerant charge levels. All components operating within manufacturer specifications. Both heating and cooling systems are now optimized and ready for seasonal operation.
Completed annual cooling maintenance visit on Lennox AC system, including comprehensive inspection of capacitor, contactor, refrigerant charge, condenser coil, evaporator coil, control board, and amp draws—all components found operating within manufacturer specifications with 19-degree temperature drop confirmed. Addressed customer concern regarding yellow indicator light and provided thermostat programming instruction for upstairs temperature optimization. Premier One Pure Flo 24x26 furnace filter ordered for replacement to complete preventive maintenance service.
Responded to service call for recently installed tanked water heater producing unusual sloshing sounds audible both at the unit and exterior vent, along with water softener displaying blue flashing indicator light. Upon inspection, identified water heater flutter and moisture present in exhaust system. Ran condensation drain line to address moisture accumulation and resolve flutter condition, restoring normal operation to the water heater unit.
Completed annual AC maintenance tune-up on two separate condensing units and one mini-split system. Performed comprehensive inspections including filters, thermostats, temperature splits, condensers, coils, motors, capacitors, compressors, refrigerant levels, and drain lines on all systems. Both standard AC units utilize R-410A refrigerant and were serviced with ambient outdoor temperature at 65 degrees. Homeowner-provided 16x25x4 filters were noted for both conventional systems. During inspection of the first AC unit, identified dual-run capacitor reading out of manufacturer specifications and recommended replacement with 40+5 MFD capacitor. Additionally, discovered contactor producing loud buzzing noise due to poor electrical contact, indicating imminent failure risk. Provided replacement estimates for both components; homeowner declined repairs at this time. Despite these findings, unit is currently operating within normal parameters. Performed maintenance on mini-split system con
Completed comprehensive AC tune-up for agreement member, including full system inspection and diagnostics of scroll compressor unit. Inspected electrical connections, wiring harness, and control panel components; all connections found secure and operational. Advised customer that air filter requires replacement and hinge-style filter needs attention for optimal system performance.
Completed biannual plumbing inspection of residential property. Thoroughly examined all accessible plumbing fixtures and components, including bathroom sink faucet assembly, water supply lines, shut-off valves, and drain system with P-trap configuration. All plumbing systems found to be functioning properly with no leaks, corrosion issues, or operational concerns identified. No repairs or replacements required at this time.
Responded to water leak emergency call for pinhole leak on copper supply line near water meter entry point in basement. Upon arrival, confirmed active leak on vertical copper pipe where main water line enters structure from ground. Leak was located on aged copper piping showing oxidation and patina, positioned adjacent to AO Smith ProLine water heater and water softening system. Performed repair of pinhole leak using appropriate copper pipe repair method. Applied white cloth wrapping at repair joints to secure connection points. Verified water meter shutoff valve was operational with red handle control. Tested repaired section under full water pressure to confirm leak was eliminated and no additional seepage was present at repair site or surrounding connections. Main water supply remained active throughout service as customer had not needed to shut off water to home prior to arrival. Documented basement utility area configuration including proximity to water heater, filtration equip
Installed four vacuum breakers on exterior hose bibs to prevent backflow contamination of the potable water supply. Investigated no hot water issue at master bathroom shower by cutting access opening through closet wall to expose shower valve assembly. Upon inspection, found corroded valve components with significant oxidation preventing proper hot water flow. Due to limited access and valve condition, recommended complete shower valve replacement, as repair attempt through existing access point was not feasible.
Completed scheduled air conditioning maintenance and tune-up on residential HVAC system. Documented equipment make, model, and serial number information with clear photographs as requested. System operational with no deficiencies noted at time of service.
Completed preventive maintenance agreement service on a 15-year-old Bryant air conditioning system. Inspected and verified air filter condition, flushed condensation drain pump, and confirmed proper blower speed operation. Removed heavy cottonwood debris buildup from outdoor condenser unit and performed thorough rinse-down. Tested and verified proper operation of capacitor, contactor, electrical wiring, control board, refrigerant charge levels, and temperature delta-t readings—all components found to be functioning within normal parameters.
Completed annual cooling maintenance on multi-zone mini split system consisting of two outdoor condensers serving three indoor head units. Performed comprehensive maintenance including filter inspection, thermostat verification, temperature differential measurements, condenser evaluation, and drainage system checks on all zones. All head units confirmed operating with proper cooling capacity and temperature output at time of service. Identified drainage issue with Mitsubishi head unit in master bedroom during initial inspection due to customer report of water appearing on stairway wall below unit location. Upon further diagnosis, discovered drain line had become disconnected from the head unit, causing improper condensate drainage. Coordinated follow-up visit to reconnect drain line and restore proper drainage function. System otherwise operating within normal parameters.
Completed annual cooling maintenance on two A/C systems utilizing R-454B refrigerant and two mini-split systems. Performed comprehensive inspection and testing of all condensers, evaporator coils, motors, capacitors, compressors, thermostats, air filters, and condensate drains. Verified proper temperature differential across coils, checked refrigerant charge levels, and confirmed electrical component operation. Serviced mini-split systems including one condenser with two indoor heads and one condenser with one indoor head. All systems tested and operating within normal parameters with no deficiencies noted at ambient temperature of 87 degrees.
Responded to water leak complaint originating from master bathroom shower/tub area with visible damage to garage ceiling below. Upon inspection, identified deteriorated grout lines and caulking around tub-to-tile transition points showing significant discoloration and moisture infiltration. Observed compromised waterproofing at shower fixture penetrations and along bathtub perimeter where tile meets tub surface. Documented existing conditions with photographs showing aged grout, possible mildew presence, and darkened caulk joints indicating chronic water seepage. Due to extent of water damage and need for comprehensive moisture remediation in affected ceiling area, referred customer to restoration specialist for proper drying, mold assessment, and structural repair before plumbing repairs can be completed.
# Galvanized Pipe Replacement Removed and replaced 15 feet of deteriorated galvanized piping with new materials. The complete repair addressed corrosion and flow restriction issues, restoring proper water delivery throughout the affected plumbing system.
Responded to return visit for recurring water leak in same location as previous repair. Located and identified pinhole leak in 1/2" copper supply line behind wall. Opened sheetrock to access affected area, cut out damaged section of copper pipe, and installed new section with proper fittings. Tested system for proper operation and verified no additional leaks present.
Responded to service call for HVAC system producing abnormal buzzing noise during operation. Upon inspection, identified the contactor as the source of the issue, exhibiting excessive vibration and audible buzzing indicating worn contact points and compromised internal components. Removed the failed contactor and installed a new 3-pole, 50-amp rated replacement unit. Verified all electrical connections were secure, tested system operation, and confirmed unit now runs quietly with proper contactor engagement and no abnormal sounds.
Completed annual cooling maintenance visit on one rooftop unit and one mini split system. Performed comprehensive tune-up procedures on both units. Identified and replaced dirty air filter with 20x25x1 filter. Inspected Daikin furnace installation and associated components including PVC venting and gas lines. All equipment operating within normal parameters upon completion of preventative maintenance procedures.