Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

How long has it been since your last electrical safety inspection? At Hurlburt, we bring your wiring up to code for safety and add features you need, like outlets and lighting. Our skilled Fridley electricians answer questions and help you plan remodeling and power panel updates. When it’s time for a new EV charging station, smart home installation, or even a whole home generator, count on local Fridley electricians to help!
For heater repair in Fridley and winter preparations or any HVAC services you need, we’re ready to help. Our team can help you understand today’s new equipment, review SEER2 and AFUE ratings for comparison, and make a smooth changeover.
For more than half a century, we’ve kept Minnesota winters at bay with expert Hurlburt heater repair in Fridley, offering summer cooling as well. Our thorough maintenance services help you get repaired for each season, raising efficiency and reliability for our valued customers!
Our Hurlburt plumbers, electricians, and heater repair experts in Fridley, MN are ready to serve you. Call today!
Hurlburt Heating & Plumbing has completed 20 jobs in Fridley, MN between November 2025 and November 2026.
The most recent job was on November 14, 2026.
Hurlburt Heating & Plumbing has completed 22 jobs in Fridley, MN in the last 12 months. The first job there was in October 2025.
Diagnosed a no-heat condition with water leaking during furnace operation by inspecting the collector box, gasket, inducer assembly, condensate trap and drain, humidifier, and related hoses; no humidifier leak was found, but rust below the blower motor confirmed water traveling through the cabinet. During extended run testing, excess water was drawn through the exhaust into the inducer assembly, causing excessive inducer noise and overflowing the condensate trap at the rear of the furnace. The vertical roof terminations for the exhaust and combustion air PVC allow rain, snow, and freezing to block the exhaust, so I recommended installing an approved rain cap or gutter-style termination and reinstalling the PVC piping with proper termination, pitch, and drainage to prevent water intrusion, blockage, and repeated condensate overflow.
Performed annual backflow prevention assembly testing to bring the expired certification current, verifying proper operation of the device in accordance with applicable cross-connection control requirements. Test results were recorded and documented to restore compliance for the boiler system's water supply connection.
Performed annual maintenance and inspection on an aging gas furnace that was operating at the time of arrival. Testing found the inducer motor drawing amperage above its rated specification, and the internal inspection camera showed rust, corrosion, and scale on the heat exchanger brackets and surrounding metal components consistent with age-related wear. Replaced the dirty air filter, and provided a quote for inducer motor replacement as well as full furnace replacement due to the unit's age and condition.
Completed comprehensive tune-up service on both air conditioning and furnace systems as part of newly activated maintenance agreement. Performed full system inspection, filter assessment, and operational testing on both units with no issues identified. All components functioning within normal parameters and systems operating efficiently.
Performed comprehensive boiler inspection for municipal compliance on a 23-year-old unit serving a multi-unit building originally constructed in 1963. Conducted thorough examination of boiler operation, safety controls, and overall system condition per city inspection requirements. During inspection, identified significant rust accumulation in the bottom of the water heater, documented findings with photographic evidence, and recommended plumber evaluation for potential water heater replacement or repair to prevent future failure or water damage.
Completed comprehensive AC tune-up and maintenance on one Rudd air conditioning system utilizing R22 refrigerant with ambient outdoor temperature at 76 degrees. Thoroughly inspected indoor air handler including filter condition, condensate drain line, blower motor operation, electrical wiring connections, and all electrical components with all items found in acceptable working condition. Verified temperature split across evaporator coil within manufacturer specifications. Conducted complete inspection of outdoor condensing unit including condenser coil cleanliness, capacitor condition and ratings, and physical condition of cabinet and components. Measured and recorded amp draw on condenser fan motor, compressor, and contactor with all readings within normal operating parameters. Evaluated refrigerant charge using industry-standard testing methods and confirmed proper charge level. System operating normally with no deficiencies noted at time of service completion.
Completed scheduled maintenance on 2-year-old Lennox heat pump and furnace system under maintenance agreement. Performed comprehensive AC tune-up including inspection of outdoor unit coils, electrical connections, control board, and contactor—all components found in good working condition with no debris or rodent nesting. Replaced air filter, verified condensate pump operation, and confirmed refrigerant charge levels within manufacturer specifications. System tested and operating properly, ready for cooling season.
Responded to no cooling call on 20-year-old residential HVAC system. Upon inspection, discovered damaged wiring and fried electrical components in outdoor unit. Replaced failed contactor and capacitor, repaired damaged wiring, and restored system operation. Verified proper system performance with good temperature splits across evaporator coil. System cooling effectively at time of departure, with partial warranty coverage applied to replaced components.
Responded to service call for 40-gallon Bradford White water heater experiencing loss of hot water and pilot light failure. Upon inspection, discovered active leak at tank base of 19-year-old unit. Attempted pilot relight resulted in water spray, confirming tank integrity failure. Removed and disposed of failed water heater. Installed new 40-gallon Bradford White residential water heater with proper venting, copper supply line connections, and code-compliant installation. Tested all connections for leaks, verified proper combustion and venting operation, and confirmed adequate hot water delivery throughout system.
Completed comprehensive plumbing inspection of residential property, including thorough examination of all water supply lines, drainage systems, and plumbing fixtures throughout the house. Hot water tank flushing was intentionally omitted per customer request due to the age of the unit to prevent potential complications. Inspected basement utility area containing iSpring water treatment system, standard water heater, and associated plumbing connections. All water lines, drains, and fixtures were found to be operating properly with no issues identified at this time.
Completed routine cooling system tune-up and maintenance inspection as part of recurring maintenance agreement. Upon evaluation, discovered compressor experiencing reduced efficiency with audible humming and significant rust corrosion present on unit exterior. Documented equipment condition with photographs showing furnace system installation and air filtration components. Advised customer that air conditioning system is losing operational efficiency and recommended planning for future compressor or complete system replacement due to deteriorating component condition.
Replaced corroded and seized laundry washing machine shut-off valves with new valves for both hot and cold water supply lines. The existing valves had deteriorated and would not turn to shut off water flow. After installation, restored water supply and performed a 10-minute leak inspection to verify proper operation before returning the system to service.
Completed pre-season AC maintenance on an 8-year-old residential air conditioning system. Upon inspection of the outdoor condenser unit, discovered significant debris buildup on the coil and an animal nest within the unit. Removed the nest material and thoroughly cleaned the condenser coil to restore proper airflow and system efficiency. Performed standard tune-up procedures to ensure the system is ready for the upcoming cooling season. System tested and confirmed operational with no current issues reported by homeowner.
Completed preventive maintenance tune-up on a 6-year-old Daikin side discharge air conditioning system under manufacturer warranty as part of plan agreement. Performed visual inspection of all components, verified temperature split across evaporator coil indicating proper refrigerant charge, and cleaned outdoor condenser coil to ensure optimal heat transfer. Due to equipment design specifications, refrigerant pressures were not measured; all other system components including blower operation, electrical connections, and safety controls tested within manufacturer specifications and system confirmed fully operational.
Replaced corroded cast iron waste lines under kitchen sink with new PVC piping to resolve active leakage. Installed new kitchen faucet fixture as part of complete plumbing update. All connections verified secure with no further signs of water damage or leakage.
Replaced noisy blower motor in bedroom ductless mini-split head unit. Performed additional cleaning of the system to address customer concern about air quality issues. Parts were ordered through comfort advisor for this first service call, with installation completed upon parts availability.
Completed warranty repair on heating system by installing replacement control board sourced from Johnstone. Verified proper system operation using Testo 510i diagnostic tool, with post-repair readings confirming successful restoration of heating function.
Responded to emergency no-heat call for 10+ year old boiler system. Found multiple issues including power/gas shutoff, low pressure, failed circulation pump, plugged vents, compromised expansion tank, and worn thermocouple. System also exhibited problems with seized water supply valve and required air vent replacement. Restored system functionality by addressing critical components; customer was advised of additional concerns regarding piping and air separator that will require future attention.
Diagnosed furnace shutdown during heating cycle. Determined circuit board was failing when gas valve energized, preventing ignition. Replaced defective control board to restore proper ignition sequence and heating function.
Responded to no heat service call for 15+ year old furnace exhibiting intermittent operation. Diagnostic inspection revealed two cracks in heat exchanger, presenting a significant safety hazard. Recommended complete heat exchanger replacement or full furnace replacement as appropriate remedial options given system age and condition.