When you have your furnace or plumbing systems repaired or installed by Hurlburt, you can be assured that it is done right. To read about other customer’s experiences with our furnace and plumber services in Fall Creek, WI, check out our online reviews below!
Hurlburt Heating & Plumbing has completed 20 jobs in Fall Creek, WI between February 2026 and May 2026.
The most recent job was on May 20, 2026.
Hurlburt Heating & Plumbing has completed 137 jobs in Fall Creek, WI in the last 12 months. The first job there was in October 2015.
Responded to no cooling call on 10+ year old air conditioning system. Found condenser unit not running with high pressure switch tripped due to severely restricted airflow. Condenser coil was completely plugged with debris, preventing proper heat rejection and causing system shutdown. Reset high pressure switch and thoroughly cleaned condenser coil to restore airflow. Tested capacitor and contactor, both within acceptable parameters. Verified indoor air filter in satisfactory condition. System restarted successfully with 21-degree temperature differential across evaporator coil, confirming proper operation. Unit now cooling effectively and operating within normal parameters.
Responded to no hot water complaint on electric tanked water heater. Upon inspection, found tripped breaker and failed upper heating element with visible damage to electrical components. Replaced faulty upper element and restored power to unit. Performed comprehensive electrical testing on both upper and lower heating elements, thermostats, and all associated wiring to verify proper voltage and functionality throughout the system. Confirmed unit began heating properly after repairs. Provided replacement options for future consideration given the unit's history as a warranty replacement and ongoing concerns about equipment longevity at this location.
Responded to complaint of sewage odor occurring only when air conditioning system operates. Removed evaporator coil cover and discovered heavy contamination with visible mold growth on both sides of coil. Blower motor exhibited rough operation during inspection. Measured temperature drop across coil at approximately 8 degrees, indicating insufficient cooling performance. Connected manifold gauges to R-22 system and confirmed low refrigerant charge. Due to combination of biological contamination, failing blower motor, refrigerant loss in R-22 system, and age of equipment, recommended complete system replacement. Customer approved thorough cleaning of existing equipment and requested estimate for new air conditioning system installation. Documented equipment condition with photographs showing Coleman brand wall-mounted unit with louvered grille. System temporarily serviced pending replacement.
Responded to a leaking electric water heater in a 3,000 square foot residential property. Upon arrival, confirmed active water leak from the existing 50-gallon electric water heater with visible water accumulation on the floor. Removed and disposed of the failed unit, then installed a new 50-gallon electric water heater with proper connections to existing copper supply lines, drain lines, and electrical service. Verified all plumbing connections for leaks, tested temperature and pressure relief valve operation, and confirmed proper electrical function and heating capability of the new unit.
Completed annual cooling maintenance visit on one-year-old Lennox air conditioning system. Performed comprehensive electrical testing with all readings within manufacturer specifications. Removed condenser panels and thoroughly cleaned coil, cleared condensate drain line, and demonstrated proper air filter replacement procedure to homeowner. System operational testing confirmed 22-degree temperature split across evaporator coil, indicating proper refrigerant charge and optimal cooling performance.
Completed plumbing inspection and addressed leaking outdoor hose bib. Upon evaluation, determined the hose bib stem was faulty and required replacement. Replaced the entire hose bib assembly to restore proper function and eliminate the leak.
Completed annual AC maintenance tune-up including exterior unit wash-down, contactor inspection, and capacitor testing. Identified unusual drain trap configuration where furnace condensate, AC drain, reverse osmosis backflush, and water softener discharge converge into single drain point. Plumbing follow-up visit scheduled to evaluate drain trap setup and ensure proper drainage functionality.
Completed Family Rewards cooling maintenance visit on heat pump system. Upon inspection, found condenser coil heavily soiled with accumulated dirt and debris, which was thoroughly cleaned to restore proper airflow and efficiency. Discovered kinked condensate drain line from evaporator coil causing potential drainage issues; removed damaged section and installed barbed 90-degree fitting to ensure proper condensate flow. Replaced air filter and performed standard heat pump operational checks. System tested and verified operating within normal parameters at 42° outdoor ambient temperature.
Completed annual air conditioning tune-up under maintenance agreement. Performed comprehensive inspection of all AC components, which were found to be in good working condition with clean coils. Due to cold ambient temperatures preventing cooling mode operation, tested system in heating mode to verify functionality, confirming proper operation with an 18-degree temperature rise across the heat exchanger.
Responded to emergency call for burst lawn faucet that caused water intrusion into basement. Upon inspection, confirmed freeze damage to exterior hose bib requiring full replacement. Installed new frost-proof sillcock with copper supply line connections, ensuring proper pitch for drainage and securing all solder joints. Homeowner elected to defer completion pending coordination with home warranty company for reimbursement authorization.
Responded to no heat call on residential HVAC system over 10 years old. Upon arrival, confirmed unit was not blowing air. Diagnosed inducer motor with locked bearing causing system failure. Removed inducer assembly and inspected for debris; confirmed bearing failure as root cause. Replaced inducer motor and reassembled draft system. While unit was open, performed heat exchanger inspection to ensure safe operation and cleaned flame sensor to optimize ignition performance. Tested draft system operation and verified proper airflow. System restored to full heating operation.
Performed comprehensive inspection and cleaning on 1995 furnace system to assess remaining service life and overall condition. Heat exchanger inspection revealed good condition with no cracks or deterioration. Addressed abnormal popping noise from burner assembly by adjusting manifold angle, which successfully eliminated the issue. Provided estimate for recommended next steps and future system considerations.
Completed annual cooling system maintenance as part of family rewards membership program. Performed comprehensive AC tune-up including cleaning routine components, flushing outdoor condenser unit, and testing system operations with satisfactory results. Inspected and replaced 1-inch furnace filter at no charge as customer had not received furnace maintenance this year.
Responded to emergency call for well system leak with water gushing from plumbing connections leading to pressure tank. Upon inspection, identified failed factory-soldered joints on tank tee fitting between well and pressure tank. Removed defective tank tee assembly and installed new tank tee with all necessary components including isolation valves, pressure switch, and pressure gauge to restore proper well system operation and eliminate active leak.
Performed furnace tune-up on 34-year-old system including flame sensor cleaning, condensate drainage verification, and electrical component inspection. Heat exchanger was examined with no concerning issues found. System was tested and confirmed to be operating properly. Homeowner elected to continue using existing equipment as it remains functional with no reported problems.
Responded to no heat complaint for aging natural gas furnace. Diagnosed blower motor locked up and failed thermostat. Performed comprehensive safety inspection with no immediate hazards found, replaced thermostat to restore basic functionality, and scheduled follow-up consultation for replacement options due to unit's overall deteriorated condition and age.
Responded to service call for water heater leaking from top connections. Diagnosed significant corrosion and rust streaking down tank side originating from upper fittings. Removed failed 50-gallon electric water heater and installed new replacement unit with proper connections to existing plumbing system.
Responded to no hot water call for A.O. Smith water heater showing error code 6-3 (lost flame). Diagnosed dirty burner assembly affecting flame sensor operation. Performed cleaning of burner unit and thermocouple to remove accumulated debris causing ignition failure. Reset system after service, confirming proper operation and flame maintenance.
Replaced 26-year-old Bradford White electric water heater experiencing electrical issues with new 50-gallon electric model. Installation completed in utility area with proper electrical connections and copper piping, restoring hot water service to the residence.
Responded to service call for no hot water. Diagnosed 50-gallon electric water heater with burnt wiring and non-functioning thermostat. Determined 26-year-old Bradford White unit with Defender Safety System requires full replacement; scheduled installation for following day pending customer approval.