Completed annual AC tune-up on residential air conditioning system. Performed outdoor condenser coil wash, tested all electrical components confirming readings within manufacturer specifications, and verified system operation with proper temperature differential of 20 degrees across the evaporator coil. Air filter was in good condition and unit operating normally with no deficiencies noted.
Performed scheduled maintenance on 2019 Goodman R410A air conditioning system paired with 2010 Bryant 40-inch furnace. Conducted comprehensive system inspection including refrigerant charge analysis, airflow measurements, and component evaluation. Job Link diagnostic readings indicated airflow below manufacturer specifications due to severely restricted 4-inch media filter heavily loaded with pet hair after only one month of service. Measured superheat at 9°F against target of 7°F, indicating refrigerant charge within acceptable parameters. Visual inspection revealed high pet hair contamination throughout system suggesting additional ductwork restriction from accumulated debris. Recommended immediate filter replacement and implementation of shortened filter change interval due to elevated pet dander load in residence. Advised duct cleaning service to address contamination and restore proper system airflow to manufacturer specifications. System operational at time of departure with all
Completed insulation of vent pipe penetrating through roof and unit heater chimney in attached garage. Applied white fibrous insulation material to exposed piping and ductwork connections to provide thermal protection and condensation control, ensuring proper wrapping coverage on all vertical penetrations and HVAC system components.
Completed routine plumbing inspection at owner-occupied residential property. Investigated reported tub drain overflow leak but was unable to recreate the issue during visit. Recommended monitoring the overflow assembly and provided estimate for replacement if leaking persists, as intermittent leaks can indicate deteriorating gaskets or improper seal at overflow connection.
Responded to a callback for a leak underneath a bathroom sink that had been previously serviced. Upon inspection, discovered that the tailpiece installed during the prior visit had sheared off, causing the leak. Removed the failed tailpiece and installed a new replacement tailpiece, securing all connections to the drain assembly and P-trap. Verified proper drainage and tested all connections for leaks to ensure the repair was complete and functioning correctly.
Responded to dispatch for iron staining issues with existing water softener system. Upon inspection, determined that the two-year-old water softener was not adequately addressing iron contamination in the water supply, resulting in brown staining throughout the home. Conducted water hardness testing and documented existing North Star water softener installation. Identified that current system configuration only includes water softening capability and lacks dedicated iron filtration equipment necessary to resolve the staining issue. Recommended installation of iron removal tower to work in conjunction with existing softener system. Submitted request for comprehensive water testing to determine iron levels and appropriate treatment specifications for proper system design.
Performed comprehensive maintenance on 11-year-old geothermal heating and cooling system. Verified all pressures and temperatures were within manufacturer specifications, inspected capacitor and contactor for proper operation, and tested electrical components with multimeter showing no voltage drop despite minor pitting observed on contactor contacts. Cleaned condensate drain line, evaluated overall cooling operation, and confirmed system is functioning properly with an estimate provided for future contactor replacement as preventive maintenance.
Performed comprehensive maintenance agreement cooling visit for newly occupied residence with multiple HVAC systems. Inspected and serviced main house air conditioning unit, including condenser coil cleaning, electrical component testing (all readings within manufacturer specifications), air filter inspection, and condensate drain line clearing. Refrigerant pressures checked and confirmed proper operation of primary cooling system. Evaluated two aging R-22 mini-split systems serving detached garage. First unit found with failed capacitor and seized fan motor; second unit had failed capacitor, incorrect contactor installed, and binding fan motor. Due to age of equipment, obsolete refrigerant, and extent of multiple component failures on both units, recommended against repair investment. Provided estimate request for electric baseboard heater installation in basement area for supplemental heating.
Responded to no-cool complaint on 10-year-old mini split system with active water leak from indoor head unit. Upon arrival, unit was off due to heavy water discharge. Connected cordless vacuum to exterior condensate drain line and extracted accumulated sludge and debris causing blockage. Cycled unit on and continued clearing drain line until flow was restored and no additional material was removed. Monitored system operation to verify proper drainage and cooling function restored.
Completed annual air conditioning tuneup on 3-year-old system per maintenance agreement. System inspected and tested with no issues found; unit operating within normal parameters with proper cooling performance.
Responded to no cooling complaint on central air conditioning system. Upon arrival, confirmed compressor was not starting. Performed diagnostic testing on electrical components and identified failed capacitor preventing compressor operation. Replaced defective capacitor with new unit and verified system startup. Checked refrigerant charge levels, which tested within acceptable range with 17-degree temperature differential across evaporator coil. Inspected air filter, condenser coil, and condensate drain line—all found clean and clear. System restored to proper cooling operation.
Completed comprehensive air conditioning tune-up and maintenance inspection on Amana outdoor condenser unit and associated indoor HVAC system. Performed thorough cleaning and multi-point system check, confirming all components operating within normal parameters with no deficiencies identified.
Responded to multiple plumbing issues throughout the residence involving kitchen and bathroom fixtures. Addressed leak underneath kitchen sink caused by deteriorated continuous waste piping; removed and replaced corroded metal drain assembly with reconfigured piping to ensure proper drainage and eliminate leak. Resolved low cold water pressure issue at bathroom faucet by removing and cleaning stem assembly, restoring adequate flow. Installed replacement pop-up drain assembly in bathroom vanity where previous mechanism was missing. Assessed toilet with inefficient flushing performance; replacement deferred pending homeowner decision. All completed repairs tested and verified operational.
Completed comprehensive AC tune-up on residential split system with all components found operating within manufacturer specifications. Replaced air filter, cleaned outdoor condenser coil, inspected electrical connections and circuit boards, verified capacitor operation, and tested system performance through full 15-minute run cycle with no issues observed.
Responded to a slow-draining kitchen sink complaint and successfully cleared a clog located approximately 40 to 50 feet into the drain line using an auger. Additionally cleaned the kitchen sink drain using a 1.5 to 3-inch bladder to ensure proper flow and prevent future blockages.
Performed return visit to investigate reported moisture leaking from roof around furnace vent pipe. Conducted thorough inspection of roof penetration and flashing, then performed water test by hosing down the vent pipe while monitoring for leaks. No active dripping was observed during testing, and pipe sealing appeared intact. Documented findings with photos of the galvanized vent stack and flashing assembly, noting weathered sealant condition. Forwarded information to install department with recommendation for follow-up visit in spring when roof is dry to reseal flashing and verify attic interior conditions.
Responded to no cooling complaint on 12-year-old Comfortmaker air conditioning system with condenser clicking but not running. Diagnosed failed dual run capacitor (35+5 MFD 440/370VAC). Replaced capacitor with ProSelect PSIRC2R355A unit and performed complete system run test. Verified proper refrigerant charge levels, inspected all electrical components, and confirmed 18-degree temperature split across evaporator coil. System restored to normal operation.
Completed comprehensive AC tune-up on 3-year-old Lennox system as part of Family Rewards maintenance agreement. Performed full inspection of indoor and outdoor components, verified air filter had been recently replaced and blower assembly was clean and properly balanced. Inspected evaporator coil, confirmed clear and draining properly. Conducted electrical testing at outdoor condenser unit with all readings within manufacturer specifications, cleaned condenser coils. Ran system through complete operational cycle for 15 minutes, measured 18-20 degree temperature split across evaporator, confirming proper refrigerant charge and system performance. All components operating to specifications with no issues identified.
Responded to service call for garbage disposal that was making loud noise before ceasing operation. Upon inspection, discovered the air switch had become unplugged from its power source. Reconnected the air switch plug and tested the disposal unit, which resumed normal operation without requiring any tools or replacement parts. Issue resolved with simple reconnection of disconnected air switch component.
Responded to no-cool complaint on 14-year-old residential air conditioning system running constantly and unable to maintain temperature setpoint. Upon inspection, identified severely restricted airflow due to heavily soiled furnace filter and dirty outdoor condenser coil causing poor heat rejection. Cleaned condenser coil thoroughly to restore proper airflow and heat transfer capability. Replaced furnace filter with customer-supplied unit. Post-service testing revealed system achieving 18–19°F temperature split across evaporator coil, indicating satisfactory cooling performance restoration. Refrigerant charge assessment inconclusive due to inclement weather conditions during testing; recommended recheck during dry, stable ambient conditions before making any refrigerant adjustments. Documented findings with photos and communicated results to homeowner with recommendations for increased filter maintenance frequency and basement dehumidification to reduce system runtime.