Diagnosed garage ceiling-mounted heating unit that was cycling on briefly then shutting down. Determined gas valve was malfunctioning - valve would initially open but then fail during operation. Replaced faulty gas valve to restore proper heating function.
Diagnosed garage heater with no-heat condition and found stuck gas valve and high gas pressure setting. Restored temporary operation by manually freeing valve and calibrating gas pressure to correct specifications. Recommended gas valve replacement to prevent recurrence of the issue.
Performed maintenance inspection on an inactive barn furnace that hasn't operated for several years. Discovered improper horizontal venting installation contrary to manufacturer specifications requiring vertical venting, and noted complete absence of ductwork and LP gas supply. Successfully tested ignition sequence to verify ignitor glow and gas valve operation. Recommended proper vertical venting installation per manufacturer requirements, addition of necessary ductwork, and suggested possible replacement with a hanging heater as potentially more suitable for the application.
Diagnosed noise concerns in customer's HVAC systems. Found heat pump noise was normal operation during defrost cycle, but identified locked inducer motor on natural gas furnace requiring replacement. Also inspected barn woodstove with locked fan motor; noted parts may be difficult to source as manufacturer is no longer in business. Prepared estimates and parts orders for both repair issues.
Responded to no-heat service call for a first-generation Heil furnace. Upon inspection, identified cracked secondary heat exchanger with water and combustion gas leakage. Visual inspection with camera confirmed failure to customer. Due to safety concerns and component failure, recommended complete system replacement. Scheduled follow-up consultation with service advisor for replacement options.
Successfully installed customer-supplied garbage disposal, ran refrigerator water line for ice maker, and replaced outdoor spigot (had to cut hose as it could not be detached). Secured all connections and verified proper operation.
Responded to a service call for a 5-year-old furnace experiencing intermittent morning no-heat issues and lockouts on ignition failure code. Performed comprehensive system inspection and tuneup, noting slightly dirty flame sensor that was not severe enough to cause malfunction. System operated normally throughout visit with no detectable faults; advised customer that intermittent control board issue could be possible but cannot be diagnosed while unit is functioning properly.
Responded to customer's initial service call for furnace inspection at recently purchased property. Upon examination, discovered multiple significant cracks in the secondary heat exchanger, which were visually confirmed with homeowner present. Due to safety concerns, the furnace was tagged out and decommissioned. Recommended replacement options and scheduled follow-up for new furnace installation quote.
Performed routine furnace tune-up on 15-year-old FRP system, including flame sensor cleaning, burner maintenance, and heat exchanger inspection. Critical finding: discovered multiple holes in the heat exchanger, presenting a significant safety concern. Tagged out and shut down the furnace per safety protocols, informed homeowner of findings and recommended immediate replacement. Customer has requested a sales advisor visit to discuss replacement options.
Diagnosed washing machine with no cold water supply. Inspection revealed failed boiler drains affecting water flow. Replaced both boiler drains to restore proper cold water supply to washing machine, ensuring full functionality of appliance.
Performed annual maintenance on two residential furnaces (17 and 21 years old). Services included cleaning flame sensors, verifying proper condensate drainage, inspecting heat exchangers, and checking electrical components on both units. Both systems operated within specifications, with temperature rises of 60° and 55° respectively. Noted minor rust on burners in the shop furnace but confirmed it remains serviceable. Customer declined scheduled boiler maintenance as it was previously serviced in July.
Replaced exterior faucet that was leaking. Accessed plumbing components through wall panel to complete installation. Customer confirmed repair was completed successfully during initial service visit with no need for follow-up appointments.
Responded to emergency service call for a broken main water valve. Customer had no water service due to gate valve stem breaking during operation. Successfully replaced the damaged gate valve with a new ball valve on the city side of the water meter, restoring full water service to the residence.
Inspected 25-year-old central wood boiler experiencing airflow issues when door is closed. Identified significant buildup in flue and cleanout areas as confirmed by visual inspection. Checked front door damper, actuator, and inside damper; recommended deep cleaning, chimney stack replacement, and scheduled follow-up consultation to discuss repair options or potential replacement given the unit's age.
Diagnosed overheating issue in upper bedrooms of residence with geothermal system. Inspection revealed two defective zone power heads that were causing constant heat calls and temperature control problems. Removed and replaced malfunctioning actuators to restore proper zoning functionality and temperature regulation.
Successfully installed customer-supplied kitchen faucet with high-arc spout and brushed nickel finish. Performed complete installation according to manufacturer specifications, ensuring proper water flow and no leaks. All connections were secured and tested for functionality.
Performed scheduled maintenance on 13-year-old Amana furnace with heat pump system. Inspected internal ductwork components and identified moisture presence requiring attention. Customer was educated on proper thermostat operation for emergency heat settings on their Pro thermostat.
Responded to no-heat complaint on a 2-year-old furnace. Discovered a chipmunk lodged in the inducer motor. Removed the obstruction, thoroughly cleaned the inducer assembly, reassembled components, and verified proper operation. System is now functioning normally with no evidence of additional blockages.
Replaced two deteriorated hose bibs (front and back of home) on this 1970's property, re-piped the kitchen sink, and installed isolation valves for both hose bibs to improve functionality and prevent future leaks. Performed thorough inspection of connecting plumbing infrastructure to ensure proper operation.