Furnaces, boilers and heat pumps are the most common heating systems in Elk Mound. We’ll go over the benefits and drawbacks of each option so that you fully understand them. Many homeowners pair a heat pump with a furnace. The heat pump provides cooling during the summer and efficient heating during the winter. When the temperature drops below freezing, the furnace kicks on. Having this reliable form of backup heat ensures you never have to worry about staying warm.
Central AC is an excellent option for homes that prefer consistent comfort and powerful cooling. We’ll perform load calculations to choose the correct size equipment. Undersizing and oversizing both waste energy and increase your cooling costs. They also result in hot and cold spots that make the home uncomfortable. Our accurate sizing process avoids these issues from the start.
If you want the most precise form of cooling, we’ll recommend a zoned setup. You’ll have room-by-room temperature control, which is great for homes with multiple floors. When you need an AC repair in Elk Mound, WI, help is just a phone call away.
Remodeling your kitchen or bathroom? If so, we can do all of the plumbing upgrades. If you’re installing a garbage disposal, we may need to add a dedicated circuit. This helps keep the breaker from tripping when using the new appliance. If you want to update the bathroom with a new toilet, we can install a low-flow model that saves water.
If you’re constantly running out of hot water, it may be time to go tankless. Tankless water heaters not only provide continuous hot water but also use less energy. This means you save money on utility bills. And because they don’t require a storage tank, there’s a lower risk of leaks and flooding.
Our electricians in Elk Mound, WI have extensive training for installing and fixing electrical systems. If you want better airflow in your home, we can install new ceiling fans.
Remodeling often requires adding new switches and outlets. We’ll consider the home’s layout and lighting when choosing where to place them.
We’ll inspect your panel to make sure it has adequate capacity. Upgrades to breakers and wiring are sometimes necessary for safety or performance reasons. You may need a full-panel upgrade to add an EV charger. 100-amp panels don’t have enough capacity to safely support EV charging. By adding a larger panel with ample capacity, you won’t have to worry about overloads.
Many homes near County Road U need sump pumps to manage spring snowmelt and heavy rainfall. Our team installs these devices, including submersible, battery backup, and pedestal types.
Homeowners along Highway 93 often have us install whole-home generators to prepare for storm-related power outages. We’ll connect the transfer switch and set up the wiring so that everything functions reliably.
If you live near Beaver Creek Reserve and want better indoor air quality, we can install a whole-home air purifier. Other solutions for indoor air quality in Elk Mound, WI include whole-home humidifiers and dehumidification systems.
Our customers love our people-driven culture. They frequently leave us 5-star reviews, praising us for our professionalism and reliability. You can read through thousands of them to see why they keep choosing us.
We come to all jobs with fully stocked trucks to fix most problems in one visit. If we ever have to turn off the home’s water or electrical supply, we’ll let you know in advance. Our fast service for emergency HVAC in Elk Mound is greatly appreciated when there are refrigerant leaks or sudden system breakdowns. We’ll arrive quickly to restore comfort with a long-term solution. The Hurlburt Family Rewards Club helps you stay on top of essential maintenance that improves the home’s energy performance and comfort.
Contact Hurlburt today to book service for electric, plumbing, HVAC, and indoor air quality in Elk Mound, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Elk Mound, WI between November 2025 and December 2025.
The most recent job was on December 22, 2025.
Hurlburt Heating & Plumbing has completed 174 jobs in Elk Mound, WI in the last 12 months. The first job there was in October 2015.
Diagnosed leaking in-floor heating system water heater, discovering internal rust and water leaking onto burner assembly. Powered up unit to verify leak source and determine system condition. Deactivated water heater as customer has furnace for primary heating; discussed replacement options including potential conversion to tankless system to replace both existing water heaters.
Diagnosed no-heat issue on 15-year-old Gibson propane furnace. Found control board failing to supply required 24V to gas valve despite audible relay click. Replaced defective control board to restore proper system operation and heat production.
Completed replacement of 4" cast iron main stack for powder bathroom with PVC piping. Service included removal of deteriorated cast iron piping from main stack to floor level at toilet and main vent/lavatory drain. Successfully installed new PVC drainage system throughout the affected area, secured within structural framework, and reset existing toilet to complete the repair.
Responded to recurring error code F008 on recently installed tankless water heater. Diagnosed issue occurring primarily during windy conditions, indicating potential combustion air/venting problem. Recommended replacement of control board after determining existing one was malfunctioning.
Replaced malfunctioning kitchen faucet and side sprayer unit after assessing plumbing system. Installed new fixture with proper connection to existing supply lines and drain assembly, ensuring proper function and no leaks upon completion.
Completed oil boiler tune-up service including nozzle and filter replacement. Inspected heat exchanger and checked for leaks throughout the system. After testing, confirmed boiler achieves target temperature with proper pressure settings and all components functioning correctly.
Performed comprehensive annual maintenance on a Lennox furnace system. Conducted full component inspection with all parts functioning properly and system operating within normal parameters. Replaced air filter and verified proper operation; no issues identified at this time.
Responded to customer complaint regarding gas burner ignition failure on outdoor wood/gas central boiler system. Diagnostic inspection revealed proper burner starting sequence but insufficient gas pressure. Determined that customer's 100lb LP tank with low-pressure regulator cannot provide adequate pressure through the underground line. Advised customer to upgrade to minimum 250-gallon LP tank with appropriate regulators to resolve the issue.
Performed scheduled furnace maintenance on 3-year-old FRP unit. Replaced dirty filter, inspected and verified clean blower assembly, tested all electrical components, and confirmed heat exchanger integrity. System operating within specifications with proper 60°F temperature rise and correct gas pressure. Verified proper venting with exterior PVC pipes clear during winter conditions.
Responded to emergency call for leaking pipe. Diagnosed a hole in the pressure switch plate causing water to gush when well pump activated. Replaced the defective 40/60 pressure switch with a new unit, restoring proper function to the residential water system.
Diagnosed 10+ year old natural gas furnace exhibiting no-heat condition. Investigation revealed system was displaying pressure switch code, but all pressure switch hoses were clear. Determined root cause was empty propane tank resulting in no gas supply to furnace. Powered down system to prevent continuous ignition attempts; advised customer to restore power after refilling propane and recommended regular tank level monitoring.
Completed comprehensive heating system maintenance across multiple areas. Addressed low water in parlor boilers, replaced defective slab sensor at parlor entry, cleaned accumulated nesting debris from two LB white heaters in half bar, and restored them to operational condition. Documented pin-hole leak in expansion tank that customer elected to monitor rather than immediately repair.
Performed diagnostic on 16-year-old heating system that was blowing cold air intermittently after resets. Inspection revealed improper combustion and upon removal of blower assembly, discovered water accumulation, darkening, evidence of rodent intrusion, and completely failed secondary heat exchanger. Equipment was tagged unsafe for operation and replacement options were provided to customer.
Responded to no-heat call for a barn boiler system. Diagnosed low water level in the aging boiler and replenished system water to restore operation. Unit is showing significant deterioration with corrosion on copper piping connections. Recommended replacement options to owner, including commercial water heater and unit heater installations, with estimates to follow.
Replaced incorrectly supplied LP water heater with appropriate natural gas model after customer reported no hot water. Original unit had been installed by third party approximately one month prior. Verified proper installation of new water heater with all gas, water, and vent connections secured and functioning correctly.
Performed comprehensive furnace tune-up on aging system for new homeowner. Discovered significant dirt accumulation on blower wheel requiring thorough cleaning. Identified deteriorating ductwork with direct exterior opening that needed replacement to restore proper system functionality and efficiency.
Performed routine maintenance tune-up on 20-year-old Lennox high-efficiency furnace. Inspected heat exchanger (good condition) and verified proper combustion. Identified corrosion on condensation trap indicating possible crack requiring replacement. System currently functioning correctly but recommended condensation trap replacement and consultation with comfort advisor for long-term reliability.
Evaluated ongoing dehumidifier installation issues in basement where customer expressed concerns about restricted access to mechanical/laundry room area. Documented current installation configuration showing dehumidifier placement and 10-inch round ductwork connection to return that blocks doorway. Assessed options for repositioning dehumidifier adjacent to furnace, which would require reworking ductwork and drain line to improve accessibility while maintaining proper system function.
Diagnosed furnace failure caused by broken intake elbows in the attic that allowed insulation to be drawn into the burner box, preventing ignition. Cleaned all plugged burner components and orifices, temporarily disconnected the intake to allow room air usage, and taped off the intake end to prevent further insulation ingestion. Requested installation crew return to properly re-vent the system.
Responded to a no heat emergency for a 20-year-old Amana LP furnace that was blowing cold air and running constantly. Discovered tripped rollout switch. Performed thorough inspection of heat exchanger but could not definitively locate compromise despite checking through blower access and top of unit. CO readings measured at 120 ppm on exhaust with visible black residue on vent pipe. Due to age and safety concerns, recommended immediate discontinuation of furnace operation and provided temporary electric heating while scheduling follow-up for replacement options.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.