Since 1959, Hurlburt has made it our mission to keep your home comfortable and protected.

Our local HVAC technicians recognize just how tough the freezing Minnesota winters can be on a home’s heating system. High heating bills and occasional breakdowns are just some of the things you can encounter when living in the area. We have what it takes to properly take care of your furnace, heat pump, or boiler and ensure your home stays nice and toasty. We can also help you find ways to ensure you don’t have to pay an arm and a leg to keep your home warm.
See our specific HVAC and IAQ services.
Heating Services We Provide:
- Heating Repair: If your heating won’t come on or isn’t keeping your house warm, you can always turn to us for help. Our team has years of experience dealing with the full range of heating issues and can work on all makes and models of heating equipment.
- Heating Installation: Looking to save money this winter by replacing your outdated heating system? We offer a range of top-quality heating solutions.
- Heating Maintenance: Join the Hurlburt Family Rewards Program and get the help you need to keep your heating in tip-top shape. Our comprehensive maintenance services will make sure you have effective, long-lasting heating.
Does your home constantly feel overly hot and muggy during the summer months? With our professional air conditioning services, you can enjoy the feeling of a cool, comfortable home all summer long. From repairs and maintenance to a new installation, our AC experts are here to help.
Count On Us for These Cooling Services:
- Cooling Repair: From refrigerant leaks to electrical issues and everything in between, we’re always ready to fix AC issues whenever they arise. We work on central ACs, central heat pumps and ductless mini-split systems.
- Cooling Installation: Are you sick of running noisy, inefficient window air conditioners in the summer? Let us help get you the right cooling system so you can save on energy and stay more comfortable.
- Cooling Maintenance: As part of the Hurlburt Family Rewards Program, we’ll also fully maintain your cooling system every year. Joining the program also provides other excellent benefits like a 15% discount on repairs.
Don’t let plumbing issues in your home spiral out of control. Common issues like leaks and poor water quality can be a nightmare to deal with every single day. Whatever plumbing problem you’re dealing with, our experienced plumbers can handle it. We’re ready to put our expertise to work for you whenever your plumbing needs repair or you require any installations.
See our specific Plumbing services.
We offer customized electrical services perfectly suited to any home. The fact that many homes in the area were built around 40 years ago means that many of them have outdated, inefficient electrical systems. Whether you need to rewire an older home or are experiencing electrical issues with a newer house, we’re the company to turn to. Our electricians maintain the highest industry standards and make sure all the work they perform is up to code.
Let Us Perform Your Electrical Work:
- Electrical Repair: Have you noticed burn marks on an outlet or lights in your house that continually flicker? Many electrical issues can be extremely dangerous and potentially lead to a fire. That’s why we offer prompt repair services and can repair any problems to make sure your electrical system is safe.
- Electrical Installation: Want to upgrade your home with a backup generator or an EV charging station? Our electricians can install anything and everything from lighting and ceiling fans to smart home equipment and more.
Whether your house is near Flying Cloud Airport or Miller Park, you can always count on us to provide timely service. When you schedule an appointment, we’ll arrive when we said we would, with everything we need to get straight to work. Our local professionals know the area well and fully understand the unique challenges that can come with living in the big city suburbs.
Our motto is “Welcome to the Hurlburt Family!” Our goal is to create long-lasting relationships by performing exceptional work at fair prices and providing top-notch customer service. When performing any HVAC, plumbing, or electrical service, we’re always ready to go the extra mile and never rest until the customer is satisfied. Check out the thousands of five-star reviews we’ve received from previous customers over the years!
Call us today to get the help of the most trusted plumbing, electrical, and HVAC company in Eden Prairie, and experience the Hurlburt difference for yourself.
Hurlburt Heating & Plumbing has completed 20 jobs in Eden Prairie, MN between May 2026 and June 2026.
The most recent job was on June 11, 2026.
Hurlburt Heating & Plumbing has completed 162 jobs in Eden Prairie, MN in the last 12 months. The first job there was in September 2025.
Completed annual cooling maintenance on two AC systems and one air source heat pump pool heater. Performed comprehensive preventative maintenance on both condensers with 454B refrigerant, including inspection and testing of filters, thermostats, temperature differential, condenser coils, motors, capacitors, compressors, refrigerant levels, and condensate drains. Both primary AC systems tested and confirmed operating within normal parameters at 68-degree ambient temperature. Inspected pool heater/AC unit and identified water leakage issue. Conducted thorough examination of filter, belt, motor, and refrigerant system, all functioning properly. Located source of water leak at drain pan, which shows rust deterioration at front section. Tested condensate drain line, confirmed draining correctly at time of service. Advised property owner of drain pan condition and recommended replacement to prevent future water damage. Property owner elected to defer drain pan replacement at this time and w
Responded to no cooling complaint on commercial rooftop unit. Upon inspection, found bent thermostat base pins preventing proper signal transmission. Repaired thermostat pins and verified connections. Discovered low voltage wiring incorrectly terminated at furnace control board. Cut and prepared new wire ends, reconnected to proper terminals per wiring diagram. Inspected rooftop condenser unit, verified refrigerant charge within specifications. Cycled system through complete operation, confirmed heating and cooling functions restored to normal parameters.
Responded to a no cool call on an older Carrier air conditioning system. Upon arrival, checked the furnace fault code which indicated a short in the low voltage circuit. Inspected the 3 amp fuse and confirmed a direct short was present. Traced the low voltage wiring through the outdoor unit and re-terminated connections between the indoor control board and outdoor low voltage terminals to isolate the fault. Tested the contactor coil and found it reading 0.5 ohms, confirming a failed and shorted coil. Replaced the outdoor contactor and re-terminated all low voltage wiring at both the indoor control board and outdoor unit connections. Rechecked system operation and confirmed the unit is now cooling normally with proper low voltage circuit function restored.
Responded to no cooling complaint and found system low on refrigerant with failed compressor. Performed insulation resistance test on compressor which confirmed electrical failure. Also discovered blown fuses in disconnect. Due to age and condition of equipment with multiple failed components, recommended and completed full system replacement of outdoor condensing unit.
Responded to no cooling complaint on 2-year-old Carrier air conditioning system for third-party evaluation of reported refrigerant leak. Upon arrival, discussed diagnostic approach involving refrigerant charge verification, dye injection, and leak detection process with property owner. Customer declined further diagnostic services, opting instead to proceed with original installing contractor who offered coil replacement under existing warranty coverage.
Responded to service call for corroded union fitting on top of recently installed A.O. Smith water heater. Upon inspection, identified corrosion on one of the upper unions connected to the copper supply lines. Successfully replaced the corroded union fitting with new brass union, ensuring proper seal and connection integrity. Tested system for leaks and verified proper water flow and pressure upon completion.
Responded to service call for HVAC zoning system malfunction where dampers were not opening fully, restricting airflow throughout the home. Replaced defective Honeywell Home zone control board with new unit sourced from local supply house. After installation, verified all zone dampers now operate and open to full position. However, upon completion testing identified secondary issue with inadequate airflow to master bedroom despite proper damper operation, indicating potential ductwork restriction or additional system component requiring further diagnosis.
Performed comprehensive AC tune-up on system experiencing poor cooling performance with weak temperature split. Found outdoor condenser coil extremely dirty with 2 dead mice and large wasp nest inside unit, severely restricting airflow and heat transfer. Cleaned condenser coil, removed debris and pest contamination, replaced failed capacitor, addressed refrigerant system issues, and replaced deteriorated suction line insulation to restore proper system efficiency and cooling capacity.
Responded to no cooling complaint on 12-year-old Lennox air conditioning system. Upon inspection, diagnosed three primary issues: low refrigerant charge, severely restricted airflow due to plugged air filter, and blocked outdoor condenser coil restricting heat transfer. Cleaned outdoor coil to restore proper airflow and heat rejection capacity. Replaced dirty air filter with new filter to ensure adequate system airflow. Added refrigerant to bring system charge to manufacturer specifications. Verified proper system operation with normal cooling restored upon completion.
Replaced leaking backyard hose bib and interior shut-off ball valve. Removed existing outdoor faucet and installed new hose bib with proper connections. Replaced faulty interior ball valve controlling the exterior water line. System was pressurized and tested for 10 minutes under full flow conditions with no leaks detected. Work area cleaned and all connections verified secure upon completion.
Responded to no cooling complaint on 22-year-old R22 air conditioning system. Upon inspection, discovered system was low on refrigerant and assessed overall condition of aging unit. Due to the system's age, R22 refrigerant type, and current refrigerant loss, recommended full system replacement and assisted in scheduling estimate appointment for new equipment installation.
Responded to no cooling call on 13-year-old system. Thermostat was set to cool with fan on auto; indoor blower was operational but outdoor condensing unit failed to start. Diagnosed no voltage present at outdoor unit, indicating electrical supply issue beyond HVAC equipment. Recommended electrician for further diagnosis and repair of electrical circuit.
Responded to service call for leaking laundry faucet connections. Successfully replaced both hot and cold water supply valves with new shut-off valves featuring cross-handle controls, resolving the leak issue. Installation completed with proper connections to existing plumbing infrastructure, restoring full functionality to the washing machine water supply system.
Responded to no cooling complaint in master bedroom on 10+ year old zoned HVAC system. Upon inspection, diagnosed failed Honeywell HZ311 zone control board causing all dampers to remain open simultaneously, resulting in inadequate airflow distribution to master bedroom. Replaced defective zone control board and damper motor to restore proper zone operation and airflow control throughout the system.
Completed seasonal AC tune-up on dual Bryant HVAC system under preventative maintenance agreement. Performed comprehensive inspection of both indoor furnace unit and outdoor condenser, verified proper operation of all components, and cleaned outdoor condenser coils to ensure optimal airflow and efficiency for cooling season.
Performed annual cooling maintenance on two 17-year-old air conditioning systems, both of which were found to be non-operational during inspection. Conducted comprehensive tune-up procedures including system diagnostics, refrigerant line inspection, and condenser coil evaluation. Customer advised that both units require replacement due to age and operational failures; estimate provided for system replacement options.
Completed biannual plumbing inspection including flushing three water heaters, inspecting water softener, sump pump, and laundry hoses. Performed comprehensive leak detection throughout the property and checked all exterior faucets for seasonal operation. All systems found to be functioning properly except the main shut-off valve, which requires replacement. Submitted estimate request for valve replacement. Documentation includes photos of shower fixtures and pressure testing equipment.
Completed annual cooling maintenance on two air conditioning systems. Performed comprehensive tuneups on both units, installed customer-supplied 16x25x4 furnace filters, verified humidifiers were properly shut down for the season, and confirmed proper operation of the zone control system. Both AC units tested and operating within normal parameters at time of service completion.
Completed annual cooling maintenance and tuneup on residential air conditioning system. Upon inspection, identified failing contactor with low voltage readings and severe corrosion on compressor terminal housing with heavy debris accumulation. Replaced defective contactor to restore proper system operation. Verified thermostat programming and setpoints functioning correctly at 66°F heat and 78°F cool settings.
Completed annual cooling tune-up on residential air conditioning system. Performed comprehensive inspection including thermostat operation, air filter, blower assembly, condenser coil condition, electrical connections, contactor, capacitor, condensate drain, refrigerant performance, and temperature split. All readings within normal operating range with no mechanical or safety issues identified. System operating properly and performing as designed with no repairs needed at this time.