Since 1959, Hurlburt has made it our mission to keep your home comfortable and protected.

Our local HVAC technicians recognize just how tough the freezing Minnesota winters can be on a home’s heating system. High heating bills and occasional breakdowns are just some of the things you can encounter when living in the area. We have what it takes to properly take care of your furnace, heat pump, or boiler and ensure your home stays nice and toasty. We can also help you find ways to ensure you don’t have to pay an arm and a leg to keep your home warm.
See our specific HVAC and IAQ services.
Heating Services We Provide:
- Heating Repair: If your heating won’t come on or isn’t keeping your house warm, you can always turn to us for help. Our team has years of experience dealing with the full range of heating issues and can work on all makes and models of heating equipment.
- Heating Installation: Looking to save money this winter by replacing your outdated heating system? We offer a range of top-quality heating solutions.
- Heating Maintenance: Join the Hurlburt Family Rewards Program and get the help you need to keep your heating in tip-top shape. Our comprehensive maintenance services will make sure you have effective, long-lasting heating.
Does your home constantly feel overly hot and muggy during the summer months? With our professional air conditioning services, you can enjoy the feeling of a cool, comfortable home all summer long. From repairs and maintenance to a new installation, our AC experts are here to help.
Count On Us for These Cooling Services:
- Cooling Repair: From refrigerant leaks to electrical issues and everything in between, we’re always ready to fix AC issues whenever they arise. We work on central ACs, central heat pumps and ductless mini-split systems.
- Cooling Installation: Are you sick of running noisy, inefficient window air conditioners in the summer? Let us help get you the right cooling system so you can save on energy and stay more comfortable.
- Cooling Maintenance: As part of the Hurlburt Family Rewards Program, we’ll also fully maintain your cooling system every year. Joining the program also provides other excellent benefits like a 15% discount on repairs.
Don’t let plumbing issues in your home spiral out of control. Common issues like leaks and poor water quality can be a nightmare to deal with every single day. Whatever plumbing problem you’re dealing with, our experienced plumbers can handle it. We’re ready to put our expertise to work for you whenever your plumbing needs repair or you require any installations.
See our specific Plumbing services.
We offer customized electrical services perfectly suited to any home. The fact that many homes in the area were built around 40 years ago means that many of them have outdated, inefficient electrical systems. Whether you need to rewire an older home or are experiencing electrical issues with a newer house, we’re the company to turn to. Our electricians maintain the highest industry standards and make sure all the work they perform is up to code.
Let Us Perform Your Electrical Work:
- Electrical Repair: Have you noticed burn marks on an outlet or lights in your house that continually flicker? Many electrical issues can be extremely dangerous and potentially lead to a fire. That’s why we offer prompt repair services and can repair any problems to make sure your electrical system is safe.
- Electrical Installation: Want to upgrade your home with a backup generator or an EV charging station? Our electricians can install anything and everything from lighting and ceiling fans to smart home equipment and more.
Whether your house is near Flying Cloud Airport or Miller Park, you can always count on us to provide timely service. When you schedule an appointment, we’ll arrive when we said we would, with everything we need to get straight to work. Our local professionals know the area well and fully understand the unique challenges that can come with living in the big city suburbs.
Our motto is “Welcome to the Hurlburt Family!” Our goal is to create long-lasting relationships by performing exceptional work at fair prices and providing top-notch customer service. When performing any HVAC, plumbing, or electrical service, we’re always ready to go the extra mile and never rest until the customer is satisfied. Check out the thousands of five-star reviews we’ve received from previous customers over the years!
Call us today to get the help of the most trusted plumbing, electrical, and HVAC company in Eden Prairie, and experience the Hurlburt difference for yourself.
Hurlburt Heating & Plumbing has completed 20 jobs in Eden Prairie, MN between July 2026 and August 2026.
The most recent job was on August 5, 2026.
Hurlburt Heating & Plumbing has completed 162 jobs in Eden Prairie, MN in the last 12 months. The first job there was in September 2025.
Performed comprehensive inspection of in-floor radiant heating system for real estate transaction. Evaluated manifold distribution system, pressure gauges, zone valves, and all associated piping and controls, confirming proper operation of all components. System found to be in good working order with no deficiencies noted at this time.
Completed spring maintenance on 20 commercial rooftop units including filter replacement with MERV-7 filters (various sizes), condenser coil cleaning, belt tension adjustments on belt-driven units, and full cooling/blower operational checks. All units tested and operating properly. Return visit required to install four 20x20x2 filters on RTU #19 which were not available on-site at time of service.
Responded to commercial HVAC service call for furnace malfunction. Diagnosed failed single-stage ignition control board preventing proper furnace operation. Sourced replacement control board from Johnstone supply in Bloomington. Removed defective ignition control board from furnace cabinet and installed new single-stage ignition control board. Verified all electrical connections were secure and properly seated. Tested furnace operation through complete heating cycle to confirm proper ignition sequence and flame sensing. Unit returned to normal operation with proper ignition timing and burner function.
Responded to no cool condition on rooftop residential unit. Diagnosed control board failure preventing power delivery to blower motor. Replaced defective control board, restoring proper system operation and cooling functionality.
Replaced flammable vapor sensor and complete flame assembly on gas-fired water heater. Verified proper operation of all components following installation to ensure safe and reliable unit function.
Completed routine plumbing inspection as part of recurring maintenance program. All plumbing systems, fixtures, and connections were visually examined and found to be in proper working order with no immediate concerns identified.
Responded to intermittent water leak in basement with standing water located behind furnace/AC unit near main plumbing stack. Conducted thorough inspection of area and documented conditions with photographs. Determined leak pattern to be inconsistent and phantom in nature, with water accumulation near HVAC equipment and ductwork. Based on location and leak characteristics, identified possible dapping issue from upstairs tub as likely source requiring further investigation by HVAC technician to assess potential condensation or drainage concerns related to mechanical systems.
Completed annual spring tune-ups on three AC systems across multiple properties, including installation of customer-supplied furnace filters and verification that humidifiers were properly shut down for the cooling season. During inspection, discovered the middle condenser/furnace system in the larger mechanical room was significantly low on refrigerant charge, indicating an active leak; added 3 lbs of R410A refrigerant and injected leak detection dye to facilitate future leak location identification. All three systems are currently operating properly, with follow-up recommended once the system loses charge again to allow sufficient dye migration for effective leak detection and repair.
Responded to callback for HVAC unit less than 10 years old with worsening condensation issues on supply air ducts. Upon inspection, confirmed extensive condensation and frost buildup on supply ductwork in attic space, indicating excessive humidity levels and inadequate insulation. Verified system operation and documented conditions with photographs showing moisture accumulation on metal ductwork and active system components with green LED indicator confirming power. Provided recommendations to customer including installation of whole-home dehumidifier to control indoor humidity levels and temporary use of lower MERV-rated air filter to improve airflow and reduce system strain until permanent solution implemented.
Completed annual spring maintenance visit on three standard air conditioning systems with three air handlers. Performed comprehensive tune-ups including system inspections, operational testing, and verification of proper refrigerant levels and electrical connections. Conducted operational checks on two mini-split systems to ensure proper performance. Serviced and cleaned the heat recovery ventilator (HRV) unit, which had been non-operational for several years, and restored it to working condition by reconnecting power supply. Installed customer-provided air filters in two of the three air handler units. All systems tested and confirmed operating within manufacturer specifications with no deficiencies noted.
Responded to no hot water complaint on a 2012 Premier Plus natural gas water heater. Diagnostic revealed a failed flammable vapor sensor triggering an error code that prevented the unit from operating. Accessed the combustion chamber, removed the defective sensor, and installed a new flammable vapor sensor. Restored power to the unit, verified proper ignition sequence, and confirmed hot water production. System tested and returned to normal operation.
Completed annual spring cooling maintenance on two air conditioning systems as part of recurring preventive maintenance agreement. Performed comprehensive tune-ups on both units, including inspection of all major components, refrigerant levels, electrical connections, and operational performance testing. The newer system's air filter was inspected and found to be in acceptable condition for continued use. The older system's air filter required removal and is scheduled for replacement by another technician. Verified proper operation of both Carrier condensing units, confirmed appropriate airflow, and tested thermostat functionality. Both systems are currently operating within normal parameters and providing adequate cooling performance.
Responded to callback for two warehouse RTUs with no cooling following previous main board replacement. RTU #4: Identified incorrect settings and wiring from prior repair; consulted with technical support and corrected control parameters and electrical connections to restore proper operation. RTU #5: Performed diagnostic check with no fault codes present; power cycled unit which restored normal operation; verified unit cycling through 2nd stage cooling multiple times with acceptable refrigerant pressures on both circuits. Noted filters nearing end of service life; scheduled replacement during upcoming fall maintenance visit.
Responded to no cooling call on a 15-year-old air conditioning system. Upon diagnosis, identified a failed capacitor as the cause of the no-cool condition. Replaced the defective capacitor and restored normal system operation.
Completed service call on warehouse rooftop unit #4 (Carrier model 40TCED16K2A6A6NVSM0) and addressed thermostat issue on unit #5. Successfully installed new main control board (terminal board HK50AA051) in unit #4 and replaced six 18x24x2 air filters as part of maintenance plan coverage. Troubleshot programmable thermostat on unit #5 and resolved screen lock issue by accessing system settings, eliminating need for replacement. Tested both units post-repair and confirmed all systems operating properly and within manufacturer specifications.
Responded to leaking drain issue caused by clogged condensate line resulting in water backup into furnace heat exchanger. Cleared drain line obstruction and installed new condensate pump with drain line to prevent future drainage failures. Upon inspection, evaporator coil pitch was found to be adequate; blockage was the primary cause of system flooding and furnace cabinet water damage.
Completed annual cooling maintenance visit on 10-year-old central air conditioning system under membership agreement. Performed comprehensive tune-up including inspection of all major components, verified refrigerant levels, checked electrical connections, cleaned condenser coils, and tested system operation. Unit operating within normal parameters with no deficiencies identified or repairs required at this time.
Responded to callback for newly installed A/C system with no cooling on upper floors. Performed comprehensive system diagnostics including thermostat verification, airflow testing at vents, air handler inspection, blower motor operation check, and temperature split measurements. Found subcool reading at 8 degrees, indicating low refrigerant charge. Added 8.6 oz of refrigerant to system, bringing subcool to optimal 12 degrees. Verified system now cooling normally throughout all floors. Recommended filter replacement and scheduled comfort advisor appointment for zone system consultation.
Responded to no airflow complaint affecting four upstairs bedrooms. Diagnosed inadequate blower speed setting when system operated in fan-only mode—adjusted blower speed from low to mid-high setting, which restored airflow to three of four bedrooms. Investigated master bedroom supply vent with zero airflow and discovered supply vent was incorrectly connected to return ductwork rather than supply trunk line, confirmed by observing spider webs being drawn inward instead of expelled outward. Unable to trace ductwork routing from basement due to concealed chase with no access points. Located and repaired two disconnected duct sections in basement using foil tape to restore proper connections. Documented misrouted master bedroom ductwork requiring replacement to establish proper supply air path—recommended scheduling estimate for ductwork rerouting and installation of access panel for future serviceability.
# HVAC Maintenance and Repair Summary Responded to a no-cooling complaint on a 14-year-old residential air conditioning system installed with an indoor coil positioned atop a newer Lennox furnace. Upon inspection, identified multiple failing components presenting immediate operational concerns and potential secondary damage risks. ## Diagnostic Findings Comprehensive system evaluation revealed several critical issues requiring immediate attention. The contactor displayed signs of electrical degradation with visible pitting and arcing damage. Capacitor testing indicated values outside manufacturer specifications, contributing to reduced system performance. Condenser fan motor exhibited bearing wear and elevated operating temperatures. Compressor amperage readings measured significantly above nameplate specifications, indicating mechanical stress and potential imminent failure. System airflow analysis identified a restriction in the refrigerant circuit. The thermal expansion valve (T
©2026 Hurlburt. All Rights Reserved.