Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 30, 2026.
Hurlburt Heating & Plumbing has completed 3,564 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to water leak spraying from shower arm pipe extending from wall. Upon inspection, discovered damaged and smashed threads on existing shower arm preventing proper seal. Removed defective shower arm and found threads severely compromised, requiring partial thread removal to achieve clean connection surface. Installed replacement shower arm and restored proper water flow to dual-head black shower system without leakage.
Replaced flammable vapor sensor on gas-fired appliance and verified proper operation. Unit fired successfully and maintained ignition for ten minutes during testing. Noted excessive blower noise during operation but confirmed adequate airflow discharge at exterior termination point.
Responded to a water leak at the laundry box where the hot water shut-off valve was actively dripping. Upon inspection, found the valve exhibited severe corrosion, oxidation, and wear from long-term moisture exposure. Replaced the deteriorated shut-off valve with a new unit, resolving the leak and restoring proper water control to the washing machine supply line.
Completed fall maintenance tune-up on 26-year-old Ruud furnace system operating normally. During inspection, discovered small amount of water accumulation on top of unit and identified issues with draft motor and attached venting. Replaced draft motor and section of venting, then sealed connections with silicone to prevent future moisture intrusion. Inspected and documented condition of pleated air filters and blower motor assembly. System tested and left in proper working order, with homeowner advised to monitor for any recurring moisture issues.
Completed comprehensive seasonal tune-up on residential Lennox air conditioning system and gas furnace. Performed full system diagnostics, operational testing, and safety inspections on both units. All components operating within normal parameters with no deficiencies identified. Both heating and cooling systems functioning properly at time of service.
Completed comprehensive furnace tune-up and safety inspection on American Standard/Trane unit. Performed routine maintenance checks including filter inspection, blower assessment, and line clearance verification—all components found within normal operating specifications. Conducted operational testing with 15-minute run cycle, confirming proper system function with 50° temperature rise across heat exchanger. During safety inspection, identified cracking beginning at burner inlet on primary heat exchanger and early signs of leakage developing on secondary heat exchanger. Documented findings with photographic evidence showing heat exchanger condition and overall system installation. Provided on-site explanation of heat exchanger deterioration and areas of concern, noting that given the age and current condition of both heating and cooling equipment, evaluation of repair versus replacement options would be advisable. System currently operational but monitoring recommended due to heat exc
Completed comprehensive plumbing inspection of residential property. Evaluated bathroom plumbing installation including wall-mounted water supply connections with braided metal supply lines and access panel in hexagonal tile surround. Inspected whole-house water treatment system consisting of dual-tank water softening and filtration equipment with digital control units, verified proper operation of system components, and confirmed all plumbing connections and PVC piping were secure and functioning correctly.
Responded to code correction callback for HVAC intake venting that did not meet SPS 323.13 (3)(b) requirements. Installed snorkel extension on intake pipe to achieve minimum 12-inch clearance above grade level. Reconfigured venting terminations on exterior wall using proper PVC fittings and mounting brackets. Verified all terminations are properly secured to siding and meet code specifications. Documented completed work with photographs showing measuring tape confirmation of proper clearance height for inspector submission.
Responded to main sewer line backup causing multiple drains throughout the property to fail. Upon inspection, identified blockages at two locations: between 79-84 feet and at 125 feet in the main line. Successfully cleared and camera inspected the closer blockage point, documenting the condition of the line. Due to the severity and distance of the secondary obstruction at 125 feet, scheduled follow-up service with hydro-jetting equipment to properly address the deeper blockage. Photographed standing water and drainage issues in basement area, including floor drain conditions and affected plumbing infrastructure showing signs of moisture exposure and corrosion.
Completed recurring plumbing inspection of residential property. Identified and resolved whistling noise issue in toilet caused by defective fill valve; removed old fill valve and installed new replacement unit. Inspected and documented water filtration system consisting of three Culligan filter units with proper mounting and blue tubing connections in utility area, confirming operational status of all components.
Responded to callback for water heater with no hot water and tripping breaker. Tested water heater operation and inspected all electrical connections at unit, confirming proper voltage and secure wiring. Upon restoring power to 30-amp circuit, observed abnormal humming and popping sounds originating from main electrical panel. Determined issue extends beyond plumbing scope to electrical system. Referred to licensed electrician for breaker and panel inspection to resolve power supply issue before proceeding with water heater service.
Completed preventative maintenance on two 4-year-old furnaces per maintenance agreement. Performed comprehensive tune-up on both units including flame sensor cleaning, electrical testing with all readings within manufacturer specifications, and camera inspection of heat exchangers with no defects or concerns noted. Both systems operating properly with no issues identified.
Replaced faulty Moen cartridge and installed new Moen valve assembly to restore proper water flow and shutoff functionality. Applied caulking around trim plate to ensure proper seal and prevent water infiltration. Tested system operation to verify complete repair and proper valve function.
Completed annual furnace tune-up on Lennox heating system. Performed comprehensive inspection per maintenance specifications, finding filter and humidifier pad recently replaced and all components clean and within manufacturer specifications. Tested furnace operation for 15 minutes, confirming proper functionality with 60° temperature rise across heat exchanger. All systems operating normally with no deficiencies noted.
Installed a pressure reducing valve assembly to regulate and maintain safe system water pressure throughout the plumbing system. The installation included a BlueFin pressure gauge with brass fittings and compression connectors, mounted with appropriate shut-off valves for system control and maintenance access. All connections were secured using proper copper piping and brass fittings to ensure leak-free operation and accurate pressure monitoring.
Replaced blower motor under parts warranty on Ruud residential furnace unit. Additionally installed new thermostat to complete the repair. System was tested in heating mode and verified operational with all components functioning properly.
Completed comprehensive furnace tune-up on Janitrol Dependable Ninety Plus high-efficiency unit. During routine maintenance inspection, identified failed blower capacitor affecting system operation. Replaced defective blower capacitor with new component and verified proper blower motor function and airflow upon completion.
Responded to leak between floor and toilet. Upon inspection, identified failed wax ring gasket and corroded closet bolts as source of water infiltration. Removed toilet from flange, cleaned mounting surface, and replaced deteriorated wax ring gasket with new seal. Installed new closet bolts and hardware. Reset toilet to flange, ensuring proper alignment and secure mounting. Tested flush operation and verified leak resolution with no water seepage at base.
Responded to emergency water leak call involving deteriorated toilet causing extensive water damage to bathroom flooring and subfloor structure. Upon inspection, found very old toilet with active leak that had been present for extended period, resulting in severe moisture damage to wooden floor, subflooring, and adjacent crawl space area. Documented extensive deterioration including heavily stained flooring, compromised structural wood members, and water infiltration beneath bathroom. Assessed damage and provided recommendations for necessary repairs including toilet replacement and floor reconstruction. Waived diagnostic fee due to customer circumstances.
Responded to a dripping water leak originating from a valve on the main water supply line in the basement. Upon inspection, identified a faulty angle valve in the plumbing assembly requiring replacement. Temporarily shut off the main water service to prevent further water damage and documented the existing configuration, which included a red-handled gate valve and multiple connection points showing signs of age and oxidation. Researched and sourced appropriate replacement part—a NIBCO NL-NK008 T-311-Y bronze angle valve with 3/4" NPT threading and handwheel actuator—and prepared a detailed estimate for the valve replacement work.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.