Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI between September 2026 and October 2026.
The most recent job was on October 1, 2026.
Hurlburt Heating & Plumbing has completed 3,564 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to callback for persistent low water pressure issue. Upon inspection, found pressure switch set incorrectly at 36 psi and pressure tank at 48 psi, creating system imbalance. Adjusted and balanced entire system to proper operating pressure of 43 psi to restore adequate water pressure throughout the residence.
Performed scheduled furnace tune-up and system inspection. During routine maintenance, discovered critical safety issue: holes detected in heat exchanger. Documented condition with photographs showing evaporator coils and HVAC components. Advised that heat exchanger replacement or full unit replacement is required due to compromised heat exchanger integrity, which poses potential carbon monoxide hazard and renders unit unsafe for continued operation.
Completed comprehensive heating maintenance inspection on 3-year-old Lennox furnace system as part of scheduled preventive maintenance agreement. Performed thorough examination of all furnace components including blower assembly, heat exchanger, gas valve, ignition system, and ventilation piping. Inspected blower wheel and housing for proper operation and airflow, verified all electrical connections, and tested safety controls. All components found to be in good working condition with no deficiencies noted. System operating within manufacturer specifications with proper combustion and adequate airflow throughout.
Performed comprehensive furnace and air conditioning tune-up on approximately one-year-old HVAC system installed in utility closet. Upon arrival, homeowner reported no current concerns with system operation. Completed full maintenance protocol on both heating and cooling systems according to standard tune-up specifications. Replaced air filter with customer-supplied unit. Conducted extended operational testing by running both systems for 15 minutes each to verify proper performance. Furnace achieved 65-degree temperature rise, indicating optimal heat exchanger function and proper airflow. Air conditioning system delivered 22-degree temperature drop across the evaporator coil, confirming adequate refrigerant charge and efficient cooling operation. Inspected evaporator coil and noted some surface discoloration and minor oxidation consistent with normal system age and humidity exposure. All components including air handler, ductwork, refrigerant lines, and electrical connections operating
Completed routine heating maintenance tune-up on gas furnace system as part of recurring maintenance agreement. Performed comprehensive inspection of all heating components including heat exchanger, burner assembly, blower motor, ductwork connections, and venting system. All components found to be operating within normal parameters with no deficiencies identified. System tested and confirmed functioning properly.
Performed scheduled heating maintenance on a 20-year-old Bryant furnace system. Upon inspection, discovered a failed heat exchanger requiring immediate attention. Conducted comprehensive system diagnostics including blower motor inspection, capacitor testing with digital multimeter (reading 25.20), and thorough examination of burner assembly and internal components. Documented equipment condition with photos showing blower assembly, dual capacitor, control board, and wiring connections. Due to failed heat exchanger presenting safety concerns, recommended comfort advisor consultation for heat exchanger replacement and burner service evaluation.
Completed comprehensive boiler preventive maintenance and tune-up on three-year-old unit with hydronic heating distribution system. Performed full inspection per manufacturer specifications including combustion analysis, safety control testing, and verification of all zone circulation pumps and manifold valves. System tested and confirmed operational for winter heating season with all components functioning within normal parameters.
Responded to gas leak on exterior supply line at residential meter location. Utility company had already marked leak at elbow fitting and shut off gas meter for safety. Documented existing conditions with photos showing meter installation, connected piping, and leak location. Unable to establish contact with customer despite multiple attempts via phone and text to provide estimate and obtain approval for repairs.
Completed return visit to address code violations on furnace installation. Installed proper copper ground wire to furnace switch per electrical code requirements. Corrected intake venting that was positioned below the minimum 12" above grade requirement per SPS 323.14 (3)(b). Replaced all furnace venting and reconfigured system by swapping intake and exhaust termination locations to meet manufacturer specifications and proper clearance distances from other exhaust terminations. Documented all corrections with photos showing compliant exterior venting configuration and interior installation.
Performed comprehensive furnace tune-up with no customer concerns reported. Replaced air filter with customer-supplied unit, inspected all system components finding them clean and within manufacturer specifications, and conducted operational testing with 15-minute runtime confirming proper function and 50° temperature rise. Recommended covering outdoor AC unit during upcoming siding installation to prevent debris contamination.
Completed scheduled heating maintenance on 6-year-old Arcoaire furnace system per maintenance agreement. Performed comprehensive furnace tune-up including inspection of internal components, blower motor, gas valve assembly, electrical connections, and burner operation. System found to be operating within manufacturer specifications with all safety controls functioning properly. Noted moderate dust accumulation beginning to build up in ductwork throughout system. Provided quote for professional duct cleaning service to improve air quality and system efficiency. Additionally provided quote for humidifier installation to address indoor air quality concerns during heating season. All wiring connections secured, combustion components inspected, and air filters evaluated. Documented system condition with photographic records of internal mechanical compartment and ventilation components. Unit left in proper working order with no immediate service needs identified.
Completed comprehensive plumbing inspection as part of recurring maintenance program. Inspected under-sink plumbing including P-trap assembly, PVC drain lines, and flexible braided supply lines, confirming proper connections and absence of leaks. Examined basement utility area plumbing systems including PVC drainage pipes, mounting hardware, and floor conditions around water heater and mechanical equipment. All plumbing components found to be functioning properly with no immediate service needs identified.
Completed annual maintenance on a 3-year-old Lennox furnace system. Performed comprehensive tune-up including cleaning of routine components, thorough testing of all operational parts, and verification of proper system function through thermostat operation. System found to be operating within normal parameters with no deficiencies noted at time of service.
Completed scheduled furnace tune-up on 2-year-old Lennox heating system as part of maintenance agreement. Performed comprehensive inspection and testing of all furnace components, verified all specifications were within manufacturer requirements, and confirmed proper system operation. All components found to be clean and operating correctly, with temperature rise measuring approximately 45° across the heat exchanger. Allowed system to run for 15 minutes under operating conditions with no issues observed. Customer had recently replaced air filter prior to visit. No concerns reported and no corrective actions required at this time.
Completed comprehensive oil furnace maintenance on older Ruud unit. Replaced oil nozzle, thoroughly inspected heat exchanger for cracks or deterioration, and cleaned spark rod to ensure proper ignition. System was run and tested to verify proper operation and safe functionality following all maintenance procedures.
Performed preventative maintenance on two furnace systems for new customer. Downstairs unit (26-27 years old) failed to ignite during testing. Inspection revealed significantly rusted burners and two cracks on heat exchanger face plate at flame entry point. Customer was shown the heat exchanger damage. Due to age and safety concerns, complete system replacement with new furnace and air conditioning unit is recommended for downstairs system. Upstairs unit (25 years old, installed with home addition) showed acceptable heat exchanger condition with all operational parameters within specification except for the inducer motor. Motor is producing excessive noise and drawing amperage above rated capacity, indicating bearing failure. Prepared parts pricing information for inducer motor replacement on upstairs system. Scheduled follow-up appointment to discuss replacement options for downstairs furnace system.
Responded to no heat call on 18-year-old furnace system. Upon arrival, confirmed blower fan was activating but furnace failed to ignite. Performed diagnostic inspection and identified failed draft inducer motor as root cause of system failure. Draft motor showed no operation when heating cycle was called for, preventing proper venting and safety lockout of ignition sequence. Documented existing system conditions including significant corrosion on gas piping and general age-related wear throughout unit. Explained findings and repair options to property owner via phone communication, as this was a rental property with owner off-site. Given the age of the equipment at 18 years and the cost of draft motor replacement, recommended comfort advisor consultation to evaluate repair versus replacement options. Provided photographic documentation of failed component and overall system condition for owner review and decision-making purposes.
Completed comprehensive furnace tune-up on 2-year-old Lennox system, performing full inspection of all components including blower assembly, motor, and heat exchanger with all equipment operating within normal parameters. Investigated homeowner's report of basement noise, identified source as hissing toilet rather than HVAC equipment, and temporarily resolved issue by shutting off water supply to fixture. Provided thermostat operation instruction to address homeowner's questions about system controls.
Responded to commercial property for non-flushing toilet backup. Inspected septic system and found first chamber at capacity. Ran camera line 140 feet from affected toilet fixture through drainage system with no obstructions or blockages detected in piping. Advised property management that septic tank requires pumping service to restore proper system function.
Performed furnace maintenance on a natural gas heating system over 25 years old. During inspection, discovered a cracked heat exchanger using video inspection equipment. Replaced air filter and documented findings with photographic evidence. Due to safety concerns with the cracked heat exchanger, recommended immediate replacement and coordinated with comfort advisor for system replacement options.