Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in October 2026.
The most recent job was on October 5, 2026.
Hurlburt Heating & Plumbing has completed 3,568 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Returned to complete leak search on mini-split system serving server rooms after previous inspection two months ago yielded no findings. Performed comprehensive leak check using UV dye and detection equipment on both mini-split units. Successfully identified refrigerant leaks on both indoor air handler coils. UV inspection revealed active leak points on evaporator coils of both heads. Units remain operational and providing cooling at this time. Submitted parts order for replacement indoor coil assemblies for both units and scheduled follow-up estimate appointment for complete mini-split system evaluation and repair options.
Responded to a water leak originating from the kitchen sink area with visible water intrusion in the basement. Upon inspection, identified deteriorating cast iron drain piping in the basement as the source of the leak. Observed that multiple sections of the cast iron drainage system had been previously replaced due to prior leak failures, indicating systemic corrosion and degradation of the remaining original piping. Documented the condition of the existing plumbing infrastructure with photographs and provided an estimate for complete replacement of the remaining cast iron drain lines throughout the residence to prevent future failures.
Completed furnace tune-up on a 5-year-old unit. Cleaned the flame sensor, tested all electrical components which were found to be within specification, and inspected the heat exchanger and burners which are in good condition. Unit is operating properly with no issues found.
Performed fall maintenance on rooftop units and responded to reported rattling noise complaint. Upon inspection of furnace system, identified failing blower motor causing excessive vibration transmitted through floor and structure. Further diagnostic revealed compromised heat exchanger with visible eyelets present, creating unsafe operating condition. Unit was immediately tagged out of service per safety protocols. Documented findings with photographic evidence showing Heil furnace installation and internal components including capacitor. Provided customer with options for repair including heat exchanger and blower motor replacement versus complete equipment replacement, as property is not customer-owned requiring landlord approval for major expenditure decisions.
Responded to a clogged bathroom sink with slow drainage and backup issues. Removed accumulated hair and debris from the drain line, restoring proper water flow and drainage function.
Responded to alarm activation reported as sump pump issue. Upon inspection, determined alarm was originating from a CyberPower battery backup unit installed in crawl space, which provides power to the property's security camera system rather than the sump pump. Unit contains dual B.B. Battery BP20-12 sealed lead-acid batteries with proper wiring connections intact. No plumbing or sump pump issues identified. Advised property owner to contact their telecommunications or security camera service provider for alarm diagnostics and resolution of the backup power system alert.
Responded to service call for leaking toilet and diagnosed failed wax ring as primary cause of leak. Removed tub stopper as requested during initial visit. Scheduled follow-up appointment to replace toilet flange, plumbing stack, and tub drain assembly to complete necessary repairs and resolve all identified plumbing issues.
Responded to no heat call on 22-year-old furnace displaying error code. Performed diagnostic inspection and determined blower motor operational but heating system non-functional. Conducted safety inspection of heat exchanger which passed visual examination. Identified failed pressure switch as root cause preventing furnace ignition sequence. Discussed repair options with homeowner who elected to purchase replacement pressure switch and perform installation independently.
Completed comprehensive furnace tune-up on 20-year-old heating system in preparation for winter season. During inspection, identified blower capacitor reading out of specification and replaced with new capacitor rated at 10ÎĽF, 370VAC. Unable to perform complete heat exchanger inspection due to silicone sealant on limit switch area. Reset furnace controls and verified proper system operation. Observed significant dust and debris accumulation on blower wheel and housing. All accessible components inspected and system confirmed operational following capacitor replacement.
Responded to no heat call on 15-year-old furnace blowing cold air. Upon inspection, confirmed gas supply present but burners failing to ignite. Found burner assembly severely rusted and corroded, preventing proper gas flow through orifices. Inducer motor bearings exhibiting excessive wear and noise, indicating imminent failure. Discovered cracked inducer transition plate behind inducer assembly with active water leakage, causing significant corrosion damage to surrounding components and base pan. Extensive rust and mineral deposits observed throughout heat exchanger compartment. Documented conditions with photos showing deteriorated mounting bracket, corroded base panel, and compromised gasket seal. Due to age of unit and extent of multiple component failures, provided customer with repair estimate requiring new inducer motor assembly, complete burner replacement, and inducer transition plate. Completed parts order form and scheduled equipment advisor consultation to discuss furnace re
Completed comprehensive plumbing inspection of residential property, including evaluation of Bradford White water heater installation and water quality testing using total hardness test strips in crawl space or attic area. Documented findings with photos and provided detailed estimates for recommended repairs or improvements identified during inspection.
Completed scheduled heating maintenance tune-up on Lennox furnace system as part of Family Rewards program. Cleaned routine components, tested all system operations via thermostat, and verified humidifier functionality with no issues found. All equipment operating within normal parameters.
Responded to basement floor drain backup with water accumulation in laundry area. Located soft plug obstruction approximately 10 feet from access point in drainage line. Successfully cleared blockage using mechanical snake equipment, restoring proper drainage flow. Obstruction was positioned beyond 90-degree pipe bend, requiring specialized technique to navigate turn and reach clog. Water damage visible on laundry room floor from backup prior to service. Drain tested and confirmed flowing freely after clearance completed.
Responded to service call for leaking garbage disposal unit. Upon inspection, determined the disposal had reached end of life and was actively leaking from the bottom housing, creating potential water damage risk to cabinet interior. Removed failed disposal unit, disconnected electrical connection and drain lines, and installed new replacement garbage disposal with proper mounting assembly, PVC drain connections, and electrical hookup to restore full functionality.
Completed comprehensive furnace tune-up on 8-year-old heating system. Performed full inspection and testing of all components including heat exchanger, burners, ignition system, blower motor, and safety controls. Inducer motor exhibited slight noise during operation but remained within manufacturer specifications and acceptable operating parameters. All electrical connections verified secure, gas pressure confirmed at proper levels, and combustion analysis showed efficient operation. System currently functioning properly with no immediate service needs identified.
Responded to floor drain backup in commercial facility. Upon arrival, found floor drain actively backing up with standing water present on tiled surface. Inspection revealed drain screens completely obstructed with accumulated debris, preventing proper drainage. Removed drain cover and strainer basket to access blockage. Cleared screens of all debris and deployed small drain snake through floor drain line to remove obstruction and restore flow. Verified proper drainage function upon completion. Area left clean and operational.
Completed comprehensive plumbing inspection on 1921-built residence as part of recurring maintenance service. Inspected shower valve assembly with brushed nickel trim and shut-off valve installation with flexible braided supply lines in recessed wall box. Documented current conditions and recommended water heater replacement due to age of existing unit.
Responded to return visit to complete toilet repair. Installed new toilet tank-to-bowl gasket to resolve leaking issue. Tested toilet multiple times following installation to verify proper seal and confirm no leaks present.
Responded to Unit 2 for water leak and moisture damage to surrounding wood paneling and sheetrock. Upon inspection, found condensate drain pan severely blocked with spiders and debris, preventing proper drainage. Flushed pan multiple times with over two gallons of water to clear blockage and verify proper flow through condensate pump. Water had entered furnace blower compartment during leak; operated fan to dry out affected area. Replaced thermostat batteries per low battery indicator. Inspected heat exchanger and venting for potential leak sources—no issues found. Tested condensate pump operation and confirmed proper function after clearing blockage.
Performed comprehensive furnace tune-up on 8-10 year old Trane unit. Cleaned flame sensor and verified proper condensate drainage. Upon inspection of heat exchanger, discovered early-stage hairline cracks typical of Trane models in this age range. Informed homeowner of findings and explained that while cracks are in beginning stages and unit is currently operating safely, heat exchanger or full furnace replacement may be needed within the next couple years. All other components checked and confirmed in good working condition. Recommended continued regular maintenance to monitor heat exchanger deterioration.