Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
See what your neighbors say about Hurlburt, and our much-loved team of HVAC contractor experts. With 24/7 service, we can heat your home day or night. Whether you need our help with a furnace repair or require a new furnace installation, we can care for your immediate home comfort needs and maintain your HVAC with our furnace maintenance plan. Turn to us for heating repair , maintenance, and heating installation!
Is your home heated with a boiler? We have boiler heating services, boiler repair, maintenance, and boiler replacement capabilities. We can even help with wood boilers! Don’t trust just anyone for your heating service needs in Eau Claire.
When it is time to buy a new air conditioner to cool your Eau Claire, WI home, you want to take out the guesswork and make sure that the AC installation and home HVAC service are above and beyond your expectations. Trust Hurlburt to serve you and your family’s air conditioning needs.Call us now for:
If you have a smaller space or home gym, you might consider having a ductless mini split for zoning your HVAC system and providing a more custom cool for your space.
An air conditioner that is leaking water can be caused by a few different factors:
If you’re experiencing an AC leak, it’s important to have a licensed HVAC technician inspect your unit to determine the root cause of the problem and make any necessary repairs.
The specific steps to fix a leaking water line depend on the type of pipe and the location of the leak. Generally, the first step is to turn off the water supply to the affected area. This can usually be done at a shut-off valve located near the leak or at the main water supply valve. Locate the source of the leak and assess the damage to determine the extent of the repair needed.To avoid any water damage or further leaks, drain the water from the pipes by turning on a faucet at a lower elevation than the leak. Depending on the extent of the damage, you may be able to repair the pipe with a patch or sealant. If the damage is more extensive, you may need to replace the damaged section of the pipe. Once the repair is complete, turn the water supply back on and check for any leaks or water damage.
If you’re not comfortable making these repairs yourself, it’s always best to contact a licensed plumber to ensure the repair is done safely and effectively.
Hurlburt in Wisconsin offers comprehensive electrical services designed to ensure your home’s electrical systems operate safely and efficiently. From meticulous electrical repairs that address immediate issues to the installation of whole-home generators for uninterrupted power during outages, their skilled technicians ensure top-tier service and reliability.
Additionally, their electrical panel services are crucial for maintaining the heart of your home’s electrical system, safeguarding against potential hazards, and improving overall electrical performance. Whether you’re upgrading your old panel to accommodate new appliances or simply ensuring your current setup meets safety standards, Hurlburt‘s expert team provides peace of mind with every service call.
Their commitment to quality and customer satisfaction makes them a trusted partner in maintaining and enhancing your home’s electrical infrastructure.
Hurlburt in Wisconsin expertly handles a wide range of electrical installation services to enhance the functionality and comfort of your home.
Whether you’re looking to modernize your space with new lighting installations that transform the ambiance of your rooms or need practical solutions like additional electrical outlets to accommodate your growing array of devices, Hurlburt’s professional team is equipped to meet your needs. They also specialize in ceiling fan installations to help you maintain a comfortable temperature year-round while improving energy efficiency.
With a commitment to safety and precision, Hurlburt ensures that every installation, big or small, is executed flawlessly to provide you with reliable and efficient electrical solutions that seamlessly integrate into your daily life.
Hurlburt in Wisconsin offers professional duct cleaning services designed to enhance both your air conditioning performance and indoor air quality. Over time, ductwork can accumulate dust, allergens, and various debris, which can impede airflow and reduce the efficiency of your HVAC system.
By choosing Hurlburt’s duct cleaning services, you can restore optimal airflow, ensuring your air conditioning system operates at peak efficiency. This not only helps in reducing energy costs but also in extending the lifespan of the system. Additionally, clean ducts significantly improve the quality of air inside your home, minimizing respiratory irritants and creating a healthier living environment.
Hurlburt’s thorough cleaning process removes contaminants effectively, providing you with cleaner, fresher air, and a more comfortable home environment.
We specialize in a variety of HVAC plumbing services, and electrical services including those mentioned above and more:
We understand the importance of keeping your home comfortable and operational all year, which is why we created our Hurlburt Family Rewards Club to help you keep your systems maintained. Additionally, we offer emergency services to ensure that you can get HVAC and plumbing services immediately.
To learn more about our expert HVAC and plumbing services, contact us today. If you want to find out what other customers are saying about our quality services, check out the reviews below!
Completed comprehensive preventive maintenance on 2015 Goodman furnace and 2022 ICP air conditioning system. Performed thorough furnace inspection including heat exchanger examination, motor operation verification, and inducer capacitor testing—all components found in good working condition. Cleaned flame sensor and condensate trap, blew out pressure switch ports to ensure proper operation. Furnace operating within manufacturer specifications. During air conditioning evaluation, discovered existing Robertshaw thermostat causing short cycling issues. Tested 2022 ICP condensing unit with capacitor and contactor readings within acceptable range. Cleaned condenser coil and verified refrigerant charge. Temperature drop measured at 19 degrees, indicating proper system performance. Identified obsolete thermostat as primary concern affecting air conditioning operation and user functionality. Provided estimate for thermostat upgrade, which was declined for same-day installation. Recommended r
Responded to no cooling condition from previous visit and diagnosed failed control board caused by defective contactor. Replaced faulty contactor at condenser unit and installed new control board under manufacturer part warranty. Tested all system modes including heating, fan operation, and cooling to verify proper system operation restored.
Responded to kitchen sink drainage issue caused by failed garbage disposal unit. Upon inspection, found 20-year-old disposal had ceased operation after attempting to grind potato skins. Removed old disposal unit and installed new garbage disposal, restoring full functionality to kitchen sink drain system. Verified proper operation and drainage upon completion.
Completed gas line repairs by installing two flare caps and capping unused gas piping on fireplaces to ensure safe system operation. Performed comprehensive tune-up on furnace, inspecting burner assembly, heat exchanger, gas valve connections, and blower components. Conducted air conditioning tune-up including inspection of refrigerant lines, electrical connections, condenser unit, and overall system performance verification.
Responded to basement water leak complaint with unknown source. Upon investigation, identified 10-year-old water heater as the source of the leak. Assessed the unit's condition and determined replacement was necessary due to age and active leaking. Documented equipment condition with photographs and provided estimate for water heater replacement to homeowner.
Performed comprehensive air conditioning tune-ups on two York brand condenser units located at the residence. Conducted thorough inspections of all components on both systems, including electrical connections, refrigerant levels, and operational controls. Both units demonstrated proper functionality with 20-degree temperature splits across the evaporator coils, indicating optimal cooling performance with no deficiencies identified.
Performed annual cooling maintenance on 10-year-old residential air conditioning system. Verified supply air temperature at 22°F split, inspected attic-mounted air handler and noted absence of condensate overflow protection device. Flushed primary condensate drain line and confirmed proper drainage. Performed complete condenser unit inspection with all electrical components and refrigerant pressures reading within manufacturer specifications. Cleaned condenser coil, verified proper system operation, and completed all maintenance checklist items per membership agreement requirements.
Responded to no hot water complaint on A.O. Smith power vent water heater that would not ignite and displayed error code indicating faulty gas valve driver circuit. Upon arrival, unit successfully ignited and ran during diagnostic evaluation. Performed thorough inspection of burner assembly, confirmed proper flame characteristics and combustion. Verified power vent system operation and checked exhaust venting for obstructions—found no blockages. Unit cycled normally and restored hot water to residence. Due to intermittent ignition failure history and gas valve driver circuit error code, provided estimates for gas valve replacement and full water heater replacement as preventative options to avoid future failures.
Responded to no cooling complaint at commercial property with two separate AC systems. First unit (1418 side): Found older R22 Goodman system with locked condenser fan motor and severely damaged fan blade; unit inoperable and requires replacement. Second unit (1416 side): Trane AC system not running due to loss of 24V power at furnace; discovered tripped rollout switch caused by cracked heat exchanger. Reset rollout to restore AC operation temporarily. Found condenser coil heavily plugged with debris, restricting airflow. Performed complete coil cleaning on Trane unit per customer approval, restored system to proper operation with 21-degree temperature differential across evaporator coil. Furnace tagged out due to failed heat exchanger presenting safety hazard; recommended immediate furnace replacement. Advised customer that R22 system requires full AC replacement due to failed motor and refrigerant phase-out. Provided estimates for all necessary repairs and replacements; awaiting buil
Responded to no cooling call on 2005 Lennox system that had not been serviced in two years. Performed comprehensive tune-up and diagnostic evaluation as part of new membership enrollment. Conducted thorough inspection of both indoor and outdoor units, noting minor cosmetic damage to condenser from pet activity but overall good condition for age. Verified refrigerant charge using Lennox approach temperature method, confirming levels within manufacturer specifications. Tested all electrical components, airflow, and system operation. System cycled properly with no mechanical or performance issues identified. Completed full preventative maintenance service and cleared unit for continued operation.
Completed comprehensive tune-up on 3-year-old Lennox SL18XC1 two-stage air conditioning system. During diagnostic testing, identified that unit was not transitioning to second stage cooling (Y2) and remained at 800 CFM on first stage only. Jumped Y1 and Y2 terminals at furnace to force second stage operation, which successfully ramped airflow to 1200 CFM, confirming proper compressor and blower function at both stages. Performed condenser coil cleaning using water wash method and completed all standard maintenance procedures. Advised homeowner of staging issue correction to improve system performance and efficiency.
Performed comprehensive cleaning and inspection on 1-year-old air conditioning system responding to customer concerns about occasional grinding noises. Upon arrival, found condenser coil heavily obstructed with accumulated debris, which was thoroughly cleaned to restore proper airflow and system efficiency. Conducted complete system evaluation including electrical components, capacitor, blower motor, and all mechanical connections—all components tested within normal operating parameters. Customer reported hearing intermittent noises in ductwork rather than from the AC unit itself; advised customer to document noise location and capture video if sounds recur to facilitate accurate diagnosis on potential follow-up visit. System currently operating properly with no mechanical issues detected after cleaning and inspection.
Completed comprehensive AC tune-up on 10-year-old Daikin heat pump system. Performed full inspection of all condenser components, verified all parts operating within manufacturer specifications, and rinsed exterior condenser coil to remove debris. Removed evaporator coil cover for internal inspection, confirmed drain pan was clean and draining properly with no blockages present. Checked air filter condition and found it clean with adequate airflow. Monitored system during full operational cycle and measured 17-degree temperature split across the coil, confirming proper refrigerant charge and system performance. All components functioning correctly with no repairs needed.
Responded to water leak in basement on main service line located just after the water meter. Upon inspection, identified deteriorated galvanized water line with multiple pinhole leaks causing drips every few seconds along a 5-6 foot section of pipe. Assessed that permanent patching was not viable due to advanced corrosion of the galvanized material. Provided estimate for section replacement and received approval to proceed. Shut off water supply, removed failed galvanized pipe section, and installed new water line using appropriate materials and fittings. Pressure tested replacement section to ensure leak-free operation and restored water service to the home. Discussed future whole-house repiping project with property owner, who expressed interest in phased approach with fixture hookup assistance.
Responded to no hot water complaint with error code 12 displaying on tankless water heater unit. Per manufacturer guidance indicating potential blockage, performed complete system diagnostics, cleaned flame rod and temperature sensors, and executed full descaling flush of heat exchanger to remove mineral buildup and restore proper water flow and heating function.
Responded to water leak originating from dishwasher area with water damage extending to basement ceiling. Upon inspection, identified failed dishwasher supply line as primary leak source. Replaced faulty supply line and conducted operational test of dishwasher unit. Testing revealed secondary leak from dishwasher motor assembly. Observed significant water damage and mold growth on surrounding floor and wall structures. Documented internal appliance conditions showing mineral buildup and component deterioration. Advised homeowner to contact restoration specialists and appliance replacement vendors for water damage remediation and dishwasher replacement due to failed motor component.
Performed comprehensive duct cleaning service throughout the residence, removing significant accumulations of lint, dust, and debris from the ventilation system. Thoroughly cleaned all accessible vents and ductwork to restore proper airflow and improve indoor air quality.
Performed comprehensive tune-up service on multiple rooftop units at commercial facility. Completed filter replacements, belt changes, and condensate drain line installations on accessible units. Conducted preliminary assessment of remaining RTUs to determine specific belt sizes and filter dimensions required for future preventive maintenance completion. Follow-up visit scheduled with proper materials to finalize all outstanding PM work.
Performed preventative maintenance on rooftop unit including cleaning equipment and replacing air filters with 20x30x2 units. Inspected air handler, condensate drain lines, and associated piping systems with all components operating properly. Identified need to order additional filters and approximately 100 feet of hose for follow-up service visit to complete maintenance requirements.
Performed AC tune-up and addressed gas leak in furnace room. Upon arrival, detected natural gas odor that homeowner reported smelling since furnace installation. Located and repaired leaking union fitting on gas line that was previously installed. After completing gas leak repair, proceeded with scheduled air conditioning maintenance service. Cleaned outdoor condenser unit and verified system operation. Measured 22° temperature split across evaporator coil with 55° ambient outdoor temperature, confirming proper cooling performance. System operating within normal parameters; no refrigerant pressure testing required due to satisfactory temperature differential and overall system performance.