Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 10, 2026.
Hurlburt Heating & Plumbing has completed 3,573 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to emergency call for severely clogged toilet causing active overflow and water damage in bathroom area. Upon arrival, assessed the situation and determined complete blockage in toilet trap. Utilized toilet auger to effectively clear the obstruction and restore proper drainage function. Verified toilet flushed properly with no further leaking or overflow issues. Left fixture in operational condition.
Responded to emergency water leak in basement with active flooding. Upon arrival, found supply line had completely detached from shut-off valve, causing continuous water discharge through basement vent despite main water supply being shut off to home. Secured the disconnected supply line and properly reconnected it to the shut-off valve, restoring proper connection and stopping the leak. Verified system integrity and confirmed no further water discharge. Documented conditions of affected bathroom area and basement with photographs showing finished bathroom space and unfinished basement with exposed joists and mechanical systems.
Completed routine air conditioning tune-up and maintenance as part of Family Rewards membership program. Performed comprehensive inspection of all routine components, thoroughly cleaned outdoor condenser unit, and conducted operational testing to verify proper system performance. No issues were identified during the service call, and equipment is operating within normal parameters.
Completed Family Rewards Program preventive maintenance visit on 2-year-old Lennox cooling system. Performed comprehensive tune-up including cleaning of routine components, flushing indoor condensate drain line, and testing all system components for proper operation. Addressed customer concern regarding increased noise levels during operation by conducting thorough inspection of both indoor air handler unit and outdoor condensing unit. Verified all electrical connections, refrigerant pressures, airflow, and mechanical components. System tested and confirmed cooling properly with all parameters within manufacturer specifications.
Completed return install visit to address insufficient cooling airflow. Increased blower speed settings by adjusting first and second stage speeds up one notch per customer request. Sealed openings on evaporator coil with caulk to improve system efficiency and adjusted pitch on drain pipe for proper condensate drainage. System tested and operating within normal parameters.
Responded to no cooling call on 3-year-old residential AC system. Upon arrival, found outdoor unit inoperative with evidence of catastrophic compressor failure - customer reported loud popping noise followed by black liquid discharge from unit. Inspection confirmed compressor had mechanically failed and blown out a retaining pin, rendering system unable to operate. Documented equipment condition with photos showing outdoor condensing unit and internal electrical components including capacitor. Advised customer of compressor failure and initiated warranty claim process given unit is well within 10-year parts coverage period.
Responded to no cooling complaint and found outdoor condensing unit humming but not operating. Diagnosed and replaced failed capacitor, restoring unit operation. Upon further evaluation, discovered system achieving only 10-degree temperature split and determined refrigerant charge was low on R-410A. Advised customer of refrigerant leak requiring repair and provided recommendations for leak detection service and system replacement options given age of equipment. Unit left operational but requiring future leak repair to restore full cooling capacity.
Responded to a dripping shower complaint and diagnosed a faulty shower cartridge as the source of the leak. Removed the existing chrome shower handle assembly, extracted the defective cartridge, and installed a new replacement cartridge to restore proper function and eliminate the water leak.
Performed comprehensive tune-up on mini-split system, including thorough washing of outdoor condenser unit and verification of all electrical connections and components. Removed and cleaned heavily soiled indoor air filters, which showed significant dust and dirt accumulation. Documented equipment make, model, and serial number information with photographs, completed operational testing of system, and confirmed unit is functioning properly.
Responded to service call for toilet with continuous running and no water entering bowl. Upon inspection, discovered malfunctioning fill valve, defective supply shut-off valve, and supply line containing an obstruction resembling a check valve preventing proper water flow. Removed old supply shut-off valve and supply line. Installed new shut-off valve and supply line to restore proper water flow to toilet fill valve, resolving the issue and returning toilet to normal operation.
Performed comprehensive cleaning service on seven rooftop and split system units at commercial facility. Washed condenser coils on five RTUs without chemical application to restore proper heat transfer and system capacity, completing work without requiring unit disassembly. Additionally cleaned two residential-style split systems serving office spaces. Inspected dual compressor configurations, refrigerant lines, and electrical connections during service. Verified proper operation of all units following cleaning procedures. All equipment tested and confirmed operational upon completion.
Completed scheduled AC tune-up and preventative maintenance on Amana HVAC system. Performed outdoor condenser coil cleaning, verified all electrical components and connections within manufacturer specifications, and confirmed proper system operation. Inspected air filter condition and determined adequate remaining service life before replacement required.
Completed comprehensive annual maintenance on both air conditioning and furnace systems under preventative maintenance agreement. Performed full tune-up procedures on outdoor condensing unit and indoor gas furnace, including system cleaning, operational testing, and safety inspections. Both HVAC systems confirmed to be functioning properly with no deficiencies noted.
Responded to no-water condition at property where main water supply valve had been shut off. Upon arrival, confirmed valve supplying water to home was in closed position. Opened main supply valve to restore water flow to entire residence, resolving issue with tub and whole-house water service.
Responded to kitchen faucet leak complaint. Diagnosed black gooseneck-style faucet with two-handle configuration leaking from spout while in closed position, indicating internal valve failure. Documented existing installation with double-basin stainless steel sink setup including separate side sprayer. Provided pricing options for faucet replacement. Customer declined service and elected to purchase and install replacement faucet independently.
Responded to service call for Lennox system displaying error code 700 with reported thermostat temperature sensor error. Upon arrival, performed comprehensive system inspection including verification of all wiring at thermostat, indoor unit, and outdoor condenser—all connections found secure and properly terminated. Conducted full AC tune-up due to lack of previous maintenance history. Condenser coil was heavily obstructed with debris and required thorough cleaning to restore proper airflow. Verified all electrical components including contactors, capacitors, and compressor amperage—all readings within manufacturer specifications. Replaced dirty air filter and cleared condensate drain line. System achieved 20-degree temperature differential across evaporator coil, confirming proper refrigerant charge and heat exchange. Cycled thermostat through multiple operations with no error codes reproduced or temperature sensor faults detected. System restored to full operational status with prope
Completed Family Rewards preventive maintenance cooling tune-up on residential air conditioning system. Upon arrival, confirmed homeowner had recently replaced air filter with unit provided from previous service visit. Performed comprehensive inspection of indoor air handler components, verifying blower assembly was clean, properly balanced, and operating efficiently. Inspected evaporator coil and confirmed clean condition with proper condensate drainage function. Conducted electrical inspection of outdoor condensing unit, testing all routine electrical components and connections. All measurements found to be within manufacturer specifications. Homeowner reported unit operating louder than normal. Investigation revealed condenser coil heavily plugged with debris and requiring cleaning to restore proper airflow and heat transfer efficiency. Performed operational testing of complete air conditioning system, monitoring performance for 15 minutes under normal operating conditions. System
Completed comprehensive tune-up maintenance on both air conditioning and furnace systems per scheduled maintenance agreement. Performed full system inspection, cleaned components, and verified operational parameters on outdoor condenser unit and indoor heating equipment. Identified improperly configured filter rack requiring replacement and arranged for service advisor to provide quote for new filter rack installation to ensure proper air filtration and system efficiency.
Performed comprehensive HVAC maintenance agreement service on both air conditioning and furnace systems at a newly constructed 2024 residence. Conducted exterior AC condenser inspection and cleaning, verified refrigerant charge levels within manufacturer specifications, and tested all cooling system components for proper operation. Connected 100-foot hose to irrigation system water source in mechanical closet for condensate drain testing. Performed furnace operational test and visual inspection of all heating components, burners, and safety controls. All equipment functioning properly with no deficiencies noted. Recommended follow-up furnace inspection during heating season for comprehensive cold-weather performance verification.