Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 11, 2026.
Hurlburt Heating & Plumbing has completed 3,576 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to no-cooling complaint on 2015 ICP R-410A split system. Upon arrival, confirmed outdoor unit fan motor was operating but system produced no cooling. Diagnosed failed dual run capacitor rated at 30/5 µF, testing at 0.1/4.9 µF on compressor terminal and 4.9 µF on fan terminal. Replaced capacitor and verified compressor and condenser fan motor operation restored. During system operation assessment, identified severe crimp in suction line at point of exit from structure, creating significant refrigerant flow restriction. Performed system performance evaluation with outdoor ambient temperature at 87°F. Recorded suction pressure at 139.1 PSIG with corresponding vapor saturation temperature of 48.5°F. Liquid line pressure measured 317.3 PSIG with condensing saturation temperature of 99.7°F. Liquid line temperature recorded at 99.4°F, yielding subcooling of only 0.3°F versus manufacturer specification of 10°F, indicating severe undercharge or restriction. Indoor temperature split m
Responded to no cooling complaint with reported hissing noise from basement area. Upon inspection, found condenser fan motor seized, dual run capacitor testing out of specification on hermetic terminal, and contactor showing significant pitting. System pressure testing revealed critically low R22 refrigerant charge, indicating active leak in refrigerant circuit. Explained findings to homeowner including multiple component failures and refrigerant leak requiring repair. Recommended obtaining leak repair estimate and scheduling consultation to review repair options versus system replacement given age of equipment and R22 phase-out considerations.
Completed annual AC tune-up on 4-year-old residential system with no reported issues. Performed comprehensive maintenance including washing the outdoor condenser unit, testing all electrical components which measured within manufacturer specifications, and verifying proper airflow with a 19-degree temperature drop across the evaporator coil. System operating at optimal performance with clean filter in place.
Responded to callback regarding sewer gas odor and drain fly issues in basement following previous sump pump installation. Upon inspection, discovered the sewer pit cover was not properly sealed, allowing gases to escape into the living space. Removed the existing cover, applied silicone sealant around the entire perimeter of the pit rim, reinstalled and secured the cover with screws, and cleaned excess sealant. Advised property owner to monitor the area for resolution of odor and pest concerns.
Performed comprehensive AC tune-up as part of routine maintenance agreement. Inspected and verified blower assembly clean and operating within manufacturer specifications. Confirmed evaporator coil clean with proper drainage and clear condensate line. Conducted thorough inspection of outdoor unit components including capacitor and contactor, noting accumulation of environmental debris and vegetation growth inside cabinet. Tested system operation for 15 minutes, confirming proper function with 18-20 degree temperature split across evaporator coil. All components operating as designed. Recommended trimming vegetation around outdoor unit to maintain proper airflow and prevent debris accumulation. Provided replacement air filter on-site.
Responded to water leak on water softener line caused by failed solder joint on main line ball valve. Removed defective valve, prepared copper pipe connections, and installed new brass ball valve with proper soldering techniques to ensure leak-free operation. Tested system under pressure to verify repair integrity and confirmed no additional leaks in surrounding plumbing assembly.
Performed comprehensive AC tune-up on 5-year-old Trane cooling system. Completed full maintenance protocol including washing outdoor condenser unit, testing all electrical components to verify proper specifications, replacing air filter, and measuring temperature differential across evaporator coil. All system parameters confirmed within manufacturer specifications and unit operating properly.
Performed preventive maintenance on four 8-year-old ground-mounted air conditioning systems. Disassembled and thoroughly cleaned all four condensers. Verified all dual-run capacitors (45/5 MFD) were operating within acceptable tolerance range of +/- 5%. Inspected all contactors for proper low voltage amperage and physical condition—all within manufacturer specifications. Measured temperature differentials across all four units, confirming 17-19 degree splits indicating proper refrigerant charge and airflow. Flushed all condensate drain pans to ensure proper drainage. Inspected air filters throughout system; replaced one severely restricted filter and recommended replacement of remaining filters per maintenance schedule. All four systems operating properly with no deficiencies noted at time of service.
Completed preventive maintenance tune-up on 10-year-old residential air conditioning system per maintenance agreement. Performed comprehensive inspection finding filter in clean condition, evaporator coil and blower assembly clear of debris with proper condensate drainage, and all routine outdoor unit components functioning within normal parameters. Addressed significant wasp infestation in outdoor unit using insecticide treatment and cleaned condenser unit. System operational testing confirmed proper performance with 18-20 degree temperature split across evaporator coil.
Responded to service call for 50-gallon natural gas water heater experiencing pilot light failure. Upon inspection, pilot light would ignite but would not remain lit, indicating likely thermocouple or gas control valve malfunction. Given the unit's age of 16 years, which exceeds the typical service life expectancy for residential water heaters, replacement was recommended rather than repair. Proceeded with complete water heater replacement, installing a new Bradford White 50-gallon natural gas water heater. Installation included proper venting connections, gas line hookup, cold water inlet and hot water outlet copper piping connections, temperature and pressure relief valve installation, and verification of all connections for proper operation and safety compliance.
Completed pre-winter maintenance tune-up on geothermal heat pump system as part of membership agreement. Flushed condensate pan, inspected and tested capacitor and contactor (both showing signs of wear), verified 20° temperature differential across system, and confirmed proper operation of pump and dump configuration. Provided estimate for capacitor and contactor replacement with truck stock parts available if customer chooses to proceed with recommended repairs.
Completed comprehensive air conditioning maintenance agreement service including full system tune-up. Replaced air filter with customer-supplied unit, verified blower assembly was clean and properly balanced, and confirmed evaporator coil was clean with proper condensate drainage. Inspected all routine components on outdoor condenser unit, verified electrical connections and capacitor condition, and confirmed unit cleanliness. Conducted operational test with 15-minute runtime, measured temperature split exceeding 20 degrees, and verified all system parameters were within manufacturer specifications. System operating properly with no deficiencies noted.
Completed membership maintenance tune-up on three geothermal units, one water-to-water geothermal system, one boiler, and steam humidifier system. Performed comprehensive inspection and servicing of all geothermal units, with particular attention to System 1 in basement serving the main living area, which showed diminished performance despite maintaining acceptable 20° temperature drop across coil. Conducted leak detection on underperforming unit with no leaks identified. Added water to geothermal loop due to low fluid levels. Cleaned and flushed all condensate drains and traps across all systems. Investigated upper-level humidity concerns reported by homeowner. Replaced air filters throughout system. Noted System 1 requires monitoring for potential low refrigerant charge, though unit remains operational within acceptable parameters at this time. Provided estimates for three geothermal system contactors showing signs of pitting and wear, as well as replacement steam humidifier canister
Completed comprehensive tune-up on 5-year-old AC and furnace systems, verifying proper operation of both units. Identified and corrected improper PVC condensate drain slope that was causing water to roll back onto the pipe; cut and reinstalled piping with proper pitch toward drain to ensure effective drainage. Discovered water in furnace room originating from water softener and coordinated plumbing contractor for same-day service to address the issue.
Completed comprehensive AC tune-up on 5-year-old Lennox system as part of family rewards maintenance agreement. Performed full system inspection with all parameters measuring within manufacturer specifications. Thoroughly cleaned outdoor condenser coil to restore optimal heat transfer efficiency and airflow through the unit.
Completed scheduled maintenance plan furnace inspection on 16-year-old Ruud and 50-year-old York HVAC systems with no reported issues. Replaced air filter and cleaned flame sensor with scotch bright pad to ensure optimal ignition performance. Verified inducer capacitor operation and inspected heat exchanger and pressure switch tubing for proper function. Checked outdoor unit terminations for debris, spiderwebs, and vegetation obstruction, removing one small tree growing near the exhaust vent to maintain proper clearance. Verified both first and second stage heating operation, confirming all systems functioning within normal parameters.
Responded to no cooling complaint on residential air conditioning system. Upon inspection of outdoor condensing unit, found compressor with severely deteriorated terminals and significant internal corrosion. Compressor terminals were non-existent due to age and environmental damage. Given the extent of deterioration, age of existing equipment (10+ years), and cost-effectiveness of repair versus replacement, recommended complete system replacement rather than compressor replacement alone. Customer approved full unit replacement. Removed old condensing unit and installed new outdoor air conditioning unit. Completed all refrigerant line connections, electrical wiring, and system startup. Verified proper operation of new equipment with system running and cooling effectively. System now operational and providing adequate cooling to residence.
Completed annual cooling maintenance on residential AC system as part of rewards membership agreement. During inspection, discovered significant long-term condensate intrusion issue on 2015 Rheem furnace originating from combustion air intake piping, causing moisture accumulation in blower compartment affecting blower deck and control board. Previous technician had recommended complete vent re-piping; instead installed Fernco-style drain-enabled fitting on intake pipe with braided drain tube and verified proper drainage function by water testing at outdoor intake. AC system (replaced 2022 or 2024, exact year unconfirmed) showed acceptable performance at time of service with normal operating pressures and 19-20°F temperature split across evaporator coil. However, homeowner reported annual refrigerant loss requiring repeated additions, with previous service company identifying suspected evaporator coil leak. Despite normal readings during current visit, historical refrigerant loss patter
Responded to emergency no-cool call at commercial auto body shop with water leaking through ceiling tiles in main office area. Found approximately 30-year-old RUUD unitary R-22 rooftop system with completely frozen suction line and evaporator coil causing active water damage to ceiling tiles and flooring. Initial diagnostic readings at 93°F outdoor ambient showed abnormal 120 psig on both suction and liquid lines. Inspection revealed condenser coil heavily plugged with grass clippings and debris, severely restricting heat rejection, along with dirty 20x20x1 filter that had not been serviced in approximately three months, causing critical airflow restriction. Performed thorough condenser coil cleaning to remove debris buildup and replaced dirty air filter. Allowed frozen coil to thaw completely before restart. Upon system restart, monitored performance and recorded only 12-13°F temperature split after 15-minute runtime, confirming significant underperformance typical of aged equipment
Completed scheduled cooling system tune-up and preventive maintenance on 7-year-old Nordyne system per Family Rewards Club agreement. Performed comprehensive inspection of outdoor Frigidaire-branded condenser unit and indoor furnace system. Conducted standard maintenance procedures including refrigerant level verification, electrical connection inspection, condenser coil cleaning, and airflow assessment. All components operating within normal parameters with no deficiencies noted. System tested and confirmed ready for cooling season operation.