Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 17, 2026.
Hurlburt Heating & Plumbing has completed 3,576 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed comprehensive AC tune-up on 27-year-old unit, finding a heavily soiled filter while blower and evaporator coil remained clean with proper drainage. Electrical inspection of outdoor unit revealed capacitor reading 32 µF on compressor side, below the rated 35 µF specification, while all other components tested within normal parameters and condenser coil was clean. System operated successfully for 15 minutes with over 15° temperature split; provided estimate for capacitor replacement per homeowner's request.
Returned to complete circuit breaker installation for HVAC system. Successfully installed 20 amp double-pole Cutler Hammer breaker, replacing previous 30 amp breaker to meet proper electrical specifications for the air conditioning unit. Installation completed and system operational.
Completed annual AC tune-up on 15+ year old system. Replaced air filter and performed comprehensive inspection of indoor and outdoor units. Blower motor and evaporator coil found clean with proper drainage. Conducted electrical inspection on outdoor unit, confirming all connections secure and condenser coil clean. Ran system for 15 minutes to verify operation, measuring temperature differential exceeding 15 degrees across evaporator coil, indicating proper refrigerant charge and system performance. Identified damper in ductwork connected to humidifier and discussed non-operational humidifier with customer. Recommended scheduling humidifier inspection during fall furnace maintenance, as humidifier operates in conjunction with heating system. All AC components functioning within normal parameters.
Installed a whole home carbon filtration system with blue housing and white PVC piping connections mounted to the utility room wall. Added a blue expansion tank to the existing Gunderson water heater, securing it with metal clamps and integrating it into the plumbing system with proper brass fittings, valves, and flexible connectors to protect against thermal expansion and ensure code compliance.
Responded to clogged toilet with drainage issues. Upon removal of toilet fixture, discovered tree roots infiltrating through the drain line and severe floor rot beneath and around the toilet base. Extensive water damage observed on surrounding wall surfaces with visible mold growth near supply line connections. Corroded plumbing components and deteriorated metal fittings documented. Property requires flooring replacement by qualified contractor prior to continuation of plumbing repairs. Follow-up service scheduled to replace PVC drain piping, install cleanout access, address water supply line concerns, and apply trenchless pipe liner. Drain line cleaning also required to clear root intrusion.
Responded to no-cool complaint on dual-zone mini-split system. Found drain pan full and overflowing due to completely plugged condensate drain line causing water leakage from indoor unit. Cleared blockage by vacuuming drain line from exterior termination point with shop vac, then flushed drain pan and verified proper drainage restored. During inspection, observed both indoor air handler blower wheels and evaporator coils were heavily contaminated with debris buildup restricting airflow. System returned to normal operation after drain line service. Provided estimate for comprehensive cleaning of both indoor heads due to excessive dirt accumulation affecting system performance and efficiency.
Performed comprehensive air conditioning tune-up on 16-year-old Rheem system as part of Family Rewards preventative maintenance program. Conducted full system inspection including visual examination of furnace, air handler, electrical components, and ductwork connections. Provided replacement air filter (20x25) and verified all components operating within manufacturer specifications with no deficiencies noted. Tested complete AC operation including airflow, electrical connections at breaker panel, and refrigerant cycle performance—all systems functioning properly with no repairs required.
Responded to no cooling complaint on 2015 system where outdoor unit failed to engage overnight. Upon arrival, system was operational but performance testing revealed failed dual run capacitor reading 23 µF on compressor side (spec: 30 µF) and 3.5 µF on fan side (spec: 5 µF). Superheat measured 26°F indicating possible low refrigerant charge, with subcooling at 5°F confirming system was slightly undercharged. Replaced out-of-spec capacitor with proper 30/5 µF unit, restoring normal compressor and condenser fan operation. System tested and confirmed operational after capacitor replacement. Provided estimate for refrigerant charge adjustment to optimize system performance.
Responded to no cooling complaint on 25+ year old RUUD system. Upon arrival, found outdoor disconnect in unknown state due to ongoing siding replacement work in neighborhood. Discovered mouse nest in outdoor unit and chewed thermostat wires. Reset power at both exterior breaker and disconnect, system immediately functioned normally with proper cooling. Removed rodent nest debris, replaced damaged thermostat wiring, and cycled power multiple times to verify consistent operation. System operated without issues through all test cycles, achieving 17-degree temperature split across evaporator coil. Advised customer of unit's age and recommended obtaining replacement estimates given advanced age of equipment. Unit left in proper working condition.
Responded to plumbing service call at a restaurant with attached apartment unit. Assessed leaking upstairs drain and provided estimate for faucet replacement. Successfully replaced bathroom faucet and drain assembly with new fixtures. Installed new stainless steel double-basin kitchen sink with single-handle chrome faucet, including all supply lines and drainage connections. All water supply connections secured with braided flexible supply lines and shut-off valves. Tested all fixtures for proper operation and verified no leaks present upon completion.
Completed annual cooling maintenance visit on 3-year-old residential air conditioning system. Performed comprehensive AC tune-up including washing outdoor condenser unit, testing all electrical components and connections, and verifying system performance. All measurements within manufacturer specifications with 20-degree temperature drop across evaporator coil, existing filter in satisfactory condition, and unit operating properly.
Performed quarterly preventive maintenance on rooftop unit A58. Replaced worn belt (4L 20x258x2 specification) and installed new filters. Tested system operation and verified proper cooling function, allowing unit to run back to setpoint temperature. Confirmed satisfactory performance with on-site staff upon completion.
Completed comprehensive air conditioning tune-up on 3-year-old outdoor condenser unit. Performed thorough washing of exterior cabinet and coils, conducted complete electrical testing with all readings within manufacturer specifications, and verified proper system operation. Unit is functioning optimally with no issues identified.
Responded to a water leak complaint at the front exterior hose bib that was recently installed. Upon inspection, identified that the bonnet nut on the brass hose bib was loose, causing water to leak when the faucet was turned on. Tightened the bonnet nut to manufacturer specifications, resolving the leak issue and restoring proper function to the outdoor faucet.
Responded to service call for natural gas water heater that would not start and continuously entered vacation mode. Upon arrival and diagnostic inspection, determined that the 10-year-old unit failed to maintain ignition and would not stay lit. Due to age of equipment and failure to operate reliably, recommended and performed complete water heater replacement. Removed existing failed unit and installed new 40-gallon power vent natural gas water heater. Connected all water supply lines, gas line, and venting system per manufacturer specifications and local code requirements. Tested new installation for proper ignition, combustion, and venting operation. Verified all connections for leaks and confirmed unit cycled properly through heating modes. System restored to full operation with reliable hot water delivery.
Performed follow-up water quality testing two months after initial water treatment system installation. Testing revealed elevated pH levels caused by inadequate well pump flow to the neutralizer tank, resulting in stagnant media bed and potential clumping. Flushed both the neutralizer and water softener units to address the issue. During system evaluation, observed stable pressure during softener operation, but insufficient media movement and pressure loss when neutralizer was flushing, confirming inadequate water supply from well pump. Left neutralizer in bypass mode to restore system functionality. Retested water pH levels, which returned to raw water baseline of 6.0-6.5 pH. Recommended evaluating well pump capacity, considering installation of smaller capacity neutralizer tank requiring reduced water volume, or removing neutralizer from system entirely to match available water supply.
Responded to service call for continuously leaking shower head in residential property. Upon inspection, identified dirty shower head as source of leak and performed necessary cleaning and maintenance to resolve issue. Assessed overall plumbing system and recommended installation of whole home water filtration system and thermal expansion tank to protect plumbing fixtures and extend their lifespan, which homeowner approved for future installation.
Responded to service call for gas line consultation related to fireplace installation. Inspected existing flexible gas line and metal supply piping for damage and serviceability. Confirmed that the 5 PSI rated flex line and all associated metal piping were in good condition with no visible damage or defects. Advised customer that existing gas line infrastructure is suitable for reconnection and to contact for assistance if fireplace installation contractor encounters any issues during connection process.
Responded to water leak emergency in basement area. Upon investigation, identified pinhole leak in copper water supply line running from basement to master bathroom. Isolated affected section of compromised copper piping in crawl space area among wooden floor joists. Cut out damaged section of copper pipe containing pinhole perforation. Installed new copper pipe section using proper compression fittings to ensure watertight seal. Tested repaired line for leaks and verified proper water pressure throughout system. Coordinated with restoration company regarding water damage mitigation. All work completed to code standards with system fully operational upon completion.
Responded to laundry room plumbing issue where hot and cold water supply valves serving the washing machine were frozen in the open position and actively leaking. Upon inspection, determined that the existing gate valves were seized and could not be repaired. Replaced both laundry supply valves with new shut-off valves featuring black wheel handles, ensuring proper water flow control and eliminating the leak. Tested both hot and cold water lines for proper operation and verified no additional leaks were present at connections.