Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 19, 2026.
Hurlburt Heating & Plumbing has completed 3,576 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed first-call confirmed 8-12FR AC tune-up on 6-year-old unit. Replaced both 16x20x1 filters, verified blower and evaporator coil were clean with proper drainage, and inspected all routine components on the outdoor unit with all measurements within manufacturer specifications. System tested for 15 minutes with proper operation confirmed, achieving over 20-degree temperature split across the evaporator coil.
Performed City of EC cross connection and backflow prevention inspection. Identified non-compliant Hydro FM 804 chemical mixing device lacking ASSE certification. Documented existing backflow assembly condition showing significant aging and corrosion on brass valves and fittings. Advised that chemical mixing company must replace non-certified device before reinspection can be completed.
Responded to service call on commercial Bryant rooftop unit and diagnosed failed compressor 1 (Emerson Copeland Scroll Compressor model ZR72KCE-TF5-950). Successfully restored temporary cooling by bringing compressor 2 online while awaiting parts approval for compressor 1 replacement. Completed sold repairs including removal and replacement of plugged liquid line filter drier and replacement of faulty high pressure switch to restore proper refrigerant flow and system protection. Unit operational on single compressor pending authorization for failed compressor replacement and additional required components.
Responded to service call for water leaking from two of three mini-split head units during cooling operation on an 8-year-old system. Inspected attic space and located one accessible condensate line serving the 35-foot line set; second problematic unit on 55-foot line set has inaccessible condensate routing. Confirmed through wiring diagram review and model specifications that these units lack factory-installed condensate pumps. Determined both condensate lines currently route upward and outward through attic space, causing drainage issues. Documented conditions with photos and recommended plan to reroute condensate lines downward and exit through side of brick exterior to resolve leaking problem.
Responded to clogged floor drain with backup issue. Upon arrival, found standing water in the pipe and debris buildup around the floor drain opening. Used high-pressure camera equipment to inspect the line running to the main sewer connection. Successfully cleared the obstruction and restored proper drainage flow.
Completed comprehensive furnace and air conditioning tune-up on 7-year-old gas furnace system as part of recurring maintenance agreement. Performed full system inspection of both heating and cooling components, replaced customer-supplied air filter, and verified blower assembly and evaporator coil were clean with no debris accumulation. Conducted thorough inspection of furnace including heat exchanger examination and gas pressure verification to ensure proper combustion. Checked all routine electrical components, safety controls, and operational sequences. Tested furnace operation with 15-minute run cycle, confirming proper performance with 55°F temperature rise across heat exchanger. Performed air conditioning system inspection and found capacitor on outdoor condenser unit showing signs of deterioration requiring replacement. All other AC components inspected and found operational. Tested cooling system with 15-minute run cycle, verifying proper refrigerant charge and system perform
Completed comprehensive AC tune-up and maintenance on 4-year-old residential cooling system. Performed thorough inspection of outdoor unit electrical components including contactor, capacitor, and wiring connections, all found to be in proper working condition. Replaced air filter and verified system operation for optimal performance.
Completed routine maintenance tune-up on 8-year-old Bryant air conditioning system and 20-year-old Tempstar furnace. During AC inspection, discovered failed dual capacitor and significant ice buildup on evaporator coil indicating restricted airflow or refrigerant issues. Replaced failed dual capacitor to restore proper compressor and fan motor operation. Assessed evaporator coil frost accumulation and identified underlying cooling system concerns. Performed comprehensive system evaluation including heat exchanger inspection on furnace unit. Coordinated with comfort advisor regarding system performance and recommended next steps for optimal operation.
Completed preventative maintenance on a 6-year-old residential air conditioning system experiencing reduced cooling performance. Performed comprehensive AC tune-up including pressure washing the outdoor condenser unit to remove debris and buildup, thorough electrical inspection of all connections and components, and verified proper operation. Confirmed air filter was recently replaced and in good condition, obtained satisfactory temperature differential across the evaporator coil, and verified system is now operating within manufacturer specifications.
Performed routine A/C maintenance on Lennox EL16XC1-024-230 unit under maintenance agreement. System operating properly with good temperature split and maintaining indoor comfort. Identified non-standard liquid line configuration with 6–8 foot reused section featuring transitions from 1/4" to 3/8" line near furnace and condenser; documented findings and submitted to install manager for review. Discovered moisture intrusion through PVC intake pipe causing condensate accumulation inside compartment; installed drain collar to divert water and prevent further internal moisture issues.
Responded to water leak complaint at kitchen sink drain. Upon inspection, identified severely corroded galvanized drain pipe extending from sink slip joint to wall connection. The galvanized tailpiece had rusted through completely, causing visible water leakage during drain usage. Verified that the drain pipe within the wall remained in serviceable condition and did not require replacement. Documented the extent of corrosion and deterioration of the exposed galvanized piping. Photographed the affected area and existing plumbing configuration for estimate preparation. Provided assessment of necessary repairs, which include removal of corroded galvanized drain assembly and replacement with modern corrosion-resistant materials. No water shut-off was required as leak was isolated to drain system rather than supply lines. Prepared detailed estimate for complete repair of kitchen sink drain tailpiece and connecting hardware as requested.
Responded to a toilet leak in the master bathroom caused by a failed tank-to-bowl gasket. Disassembled the toilet tank from the bowl, removed the deteriorated gasket, and installed a new tank-to-bowl gasket to create a proper seal. Reassembled the toilet and verified the repair eliminated the leak.
Installed comfort tee and recirculation pump system on tankless water heater to enable hot water circulation throughout the residence. Replaced T-fitting inside the boiler system to accommodate the new recirculator configuration. Installed closet flange for downstairs toilet, securing it properly to the subfloor, and noted that a 10-inch rough-in toilet may be required for proper fit in that bathroom. Tested recirculation system for proper operation and confirmed all components functioning correctly.
Completed annual air conditioning tune-up and preventative maintenance inspection. Replaced dirty air filter, verified blower and evaporator coil were clean and operating within specifications, performed electrical inspection on outdoor condensing unit, and cleaned condenser coil. System tested for 15 minutes with proper operation confirmed and temperature split exceeding 25 degrees across the evaporator coil.
Responded to low water pressure issue caused by heavily clogged iron filter. Upon inspection, found filter cartridge completely caked with sediment and iron buildup, restricting flow throughout the system. Removed and replaced the iron filter cartridge, restoring proper water pressure and system functionality.
Completed comprehensive seasonal air conditioning tune-up on 5-year-old residential unit. Performed thorough cleaning of outdoor condenser coil, conducted complete electrical testing with all readings within manufacturer specifications, replaced air filter, and verified system performance with temperature differential measurements confirming proper cooling operation.
Responded to service call at mobile home to assess HVAC system in closet location. Upon arrival, discovered significant structural damage with rotted flooring beneath 2018 90% efficiency furnace and evaporator coil assembly. Evaluated existing R-410A air conditioning system and furnace with PVC venting installed through metal roof. Documented extensive deterioration of subfloor requiring structural repairs before equipment can be safely supported. Photographed PVC vent terminations extending above roofline, internal furnace components including heat exchanger coils, refrigerant lines, gas line connections, and electrical wiring configurations. Assessed equipment removal requirements to allow access for floor replacement work. Equipment will need complete disconnection of gas supply, electrical connections, refrigerant lines, condensate drainage, and PVC vent piping for temporary removal. Prepared photographic documentation of existing installation configuration to facilitate proper rei
Responded to no-cooling complaint on 10+ year old R-22 air conditioning system. Upon arrival, found severely restricted air filter and outdoor condenser coil heavily blocked with debris, both significantly limiting airflow and heat rejection capacity. Cleaned outdoor unit, thoroughly rinsed condenser coil to restore heat transfer, and addressed airflow restrictions. After cleanup, verified system operation with refrigerant diagnostics showing 22.5°F temperature split, 10.9°F actual superheat against 12.2°F target superheat, confirming proper refrigerant charge and system performance. System restored to normal cooling operation with improved comfort levels.
Responded to no cooling callback and found indoor unit operating properly with good airflow, but outdoor condenser completely non-functional. Diagnosed failed dual-run capacitor (40/5 MFD) with failure on both common and fan terminals. Condenser fan motor exhibited elevated temperature and increased bearing resistance, indicating imminent failure. Replaced faulty capacitor and verified system operation with all components functioning correctly. Advised customer that fan motor shows signs of deterioration and recommended obtaining estimate for motor replacement, as current repair serves as temporary solution. Customer approved continuation of service with existing motor and agreed to pursue future motor replacement estimate.
Responded to service call for low water pressure in shower and stuck lavatory strainer. Removed and cleaned clogged flow restrictor from shower head, restoring proper water pressure. Replaced stuck lavatory strainer with new unit to restore proper drain function. Addressed bathtub diverter malfunction preventing switching from tub spout to shower mode, completing all necessary repairs to restore full functionality of bathroom fixtures.