Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 20, 2026.
Hurlburt Heating & Plumbing has completed 3,576 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed comprehensive AC tune-up and maintenance inspection in response to concerns about nighttime noise from outdoor unit. Replaced dirty air filter, verified blower and evaporator coil cleanliness, confirmed proper condensate drainage, and performed routine electrical inspection on outdoor unit with all readings within manufacturer specifications. System tested for 15 minutes with normal operation confirmed, achieving over 23° temperature differential across the coil, and outdoor unit operating quietly with no abnormal sounds detected.
Responded to no hot water complaint on A.O. Smith tanked water heater. Upon arrival, confirmed unit was not producing hot water. Control board displayed 3-flash error code indicating TCO or pressure switch failure in open position. Attempted reset and observed blower motor startup, but ignition sequence failed to initiate. Unit cycled through attempted ignition 3-4 times before shutting down, confirming communication failure between blower assembly and control board. Diagnosed blower motor assembly malfunction preventing proper signal transmission to ignition system. Documented equipment condition with photos and provided customer with repair options and cost estimates for blower motor replacement and associated components to restore proper operation.
Completed comprehensive whole-house duct cleaning in preparation for upcoming furnace replacement. Removed accumulated lint, dust, and pet dander from main trunk lines and branch ducts throughout the system, with particular attention to debris buildup from household cats. Cleaned all supply and return vents, inspected ductwork interior for contamination, and ensured system was free of obstructions prior to new equipment installation scheduled for the following week.
Performed comprehensive annual tune-up on both air conditioning and furnace systems at residential property. Completed routine maintenance including cleaning of essential components, thorough testing of all system controls and safety devices, and operational verification of equipment. Serviced Lennox outdoor condenser unit, confirming proper airflow through louvers, fan operation, and electrical connections at disconnect. All systems tested and running within normal operating parameters upon completion.
Completed annual maintenance on residential Lennox furnace and Lennox Elite air conditioning system. Performed comprehensive tune-up including cleaning of routine components on both units, thorough system testing, and operational verification. All equipment found to be functioning properly with no issues identified during inspection.
Completed comprehensive maintenance tuneup on both air conditioning and furnace systems, both less than five years old. Performed full system inspection and testing on indoor air handler and outdoor condenser unit, verifying all electrical connections and measurements were within manufacturer specifications. Cleaned outdoor condenser coil, confirmed air filter condition, and conducted operational testing of both heating and cooling modes with satisfactory performance results.
Responded to service call for water heater not producing hot water. Upon inspection, confirmed active leak from tank indicating internal failure. Assessed unit age and condition, documented existing installation in unfinished basement area with overhead utilities and electrical panel proximity. Provided replacement options and estimates to customer for new water heater installation due to failed tank beyond repair.
Completed annual Family Rewards cooling tune-up on residential air conditioning system. Replaced dirty air filter, verified blower assembly and evaporator coil were clean with proper condensate drainage. Performed electrical inspection on outdoor condenser unit and identified capacitor reading 28 MFD on compressor terminal, below specification for 40/5 MFD dual run capacitor. Cleaned condenser coil and tested system operation, confirming proper functionality with temperature split exceeding 20 degrees across evaporator. System ran continuously for 15 minutes without issues. Provided findings and recommended capacitor replacement; customer requested estimate for repair.
Responded to a drain stoppage issue in a sewer line up to 4" diameter. Upon arrival, performed mechanical root removal from the main sewer line using drain cleaning equipment, extending up to 150 feet. Located and addressed a critical junction point where the lateral sewer line connects to the main, which had significant root intrusion causing the blockage. Successfully cleared all root obstructions from the entire pipe run using mechanical cable machines, restoring proper drainage flow. This follow-up service was coordinated to allow for planned flooring installation work to proceed.
Responded to callback regarding two toilets experiencing slow fill times following recent fill valve replacements. Upon inspection, found one 55-year-old toilet and one 30-year-old toilet with heavily discolored tank water, significant sediment buildup, and extensive staining on interior tank components. Determined that age-related deterioration and mineral deposits were compromising system performance despite new fill valves. Recommended full toilet replacements rather than continued repairs due to advanced age and condition of fixtures. Provided replacement options and pricing for homeowner consideration.
Completed preventative maintenance on a 3-year-old air conditioning system. Condenser coil was heavily obstructed with cottonwood debris and thoroughly rinsed clean to restore proper airflow. Verified thermostat settings, installed customer-supplied filter, and reset maintenance reminder for six-month interval.
Completed annual maintenance on both furnace and air conditioning systems. Performed comprehensive inspection and testing of all electrical components on both units, confirming all readings were within manufacturer specifications. Verified air filter had been recently changed and inspected blower wheel, which was found to be clean. Tested furnace operation with successful startup and confirmed proper heating performance with 50-degree temperature rise across heat exchanger. Proceeded to air conditioning system and removed access panels for inspection. Cleaned condensate drain line and discovered bee nests within unit, which were removed and area cleaned thoroughly. Verified all electrical connections and components were secure and functioning properly. Confirmed evaporator coil drain line was draining correctly without blockages. Started air conditioning system and verified proper operation with 20-degree temperature drop across evaporator coil, indicating adequate refrigerant charge
Completed kitchen faucet replacement over two service visits. During the first visit, disconnected existing kitchen sink plumbing and prepared the workspace for new fixture installation. Returned the following day to install customer-supplied kitchen faucet, reconnected all sink plumbing including drain assembly and P-trap configuration, and verified proper operation of the disposal unit connections. All work completed per the original estimate with no leaks detected upon final inspection.
Completed comprehensive maintenance inspection on 2022 American Standard split system. Cooling system operating within specifications—TXV subcooling maintained steady at 10°F (range 9.8°F–11.2°F) over 10-minute observation period with 72°F outdoor ambient temperature; all electrical components tested and verified operational. Heating system evaluation revealed ignition failure with only one of three burners lighting despite proper HSI glow and gas valve operation. Diagnosed cause as rust and debris obstruction in burner carryover channels preventing flame propagation. Removed burner assembly, thoroughly cleaned all carryover ports, reinstalled burners, and verified full ignition sequence across all three burners with normal operation restored.
Responded to report of mystery water leak with thumping sound, suspected plumbing pipe leaking onto ductwork. Investigated ceiling leak by creating access openings to inspect area. Found evidence of active water leak affecting ceiling and structural components, but unable to determine exact source location without additional investigation. Observed PVC piping, wooden structural beams, and insulation within ceiling cavity. Documented conditions with photographs. Due to homeowner's unavailability until following Monday, shut off main water supply to home to prevent further damage. Follow-up visit scheduled upon homeowner's return to utilize inspection camera equipment, pinpoint exact leak location, and complete necessary repairs.
Responded to refrigerant leak on mini-split system where UV dye from previous service indicated leaking flared fittings at the outdoor unit. Properly tightened flare connections, performed nitrogen pressure test to verify leak repair, and evacuated system to manufacturer specifications. Recharged system to factory specifications and performed operational testing to confirm proper function of equipment.
Completed comprehensive duct cleaning service addressing significant dust and lint accumulation throughout the HVAC system. Cleaned and serviced 15 openings including both supply and return ducts, removing heavy debris buildup and discoloration from interior duct surfaces. All vents were thoroughly cleaned and cleared to restore proper airflow and system efficiency.
Replaced defective generator control board under parts and labor warranty. Upon installation, discovered the failed control board had drained the battery completely, requiring battery replacement. After control board reset, attempted Wi-Fi reconnection but system would not connect. Contacted technical support who recommended installation of a Wi-Fi extender to resolve connectivity issue. Performed scheduled generator maintenance while on site. Follow-up visit required to complete Wi-Fi reconnection once extender is installed.
Performed comprehensive AC tune-up on 5-year-old Lennox system. Inspected blower assembly, found clean and balanced; evaporator coil clean with proper drainage. Discovered humidifier incorrectly set to on position and damper in winter position, adjusted both to summer settings. Conducted electrical inspection on outdoor unit, all readings within manufacturer specifications. Replaced air filter per customer request. System tested and operational with 20-degree temperature differential across coil, confirming proper cooling performance.
Completed comprehensive cooling maintenance on a 5-year-old Lennox XP16 heat pump system. The outdoor condenser coil was severely obstructed with cottonwood debris on all four sides, restricting airflow; performed thorough coil cleaning to restore proper operation. Inspected control board, electrical wiring connections, and verified refrigerant charge—all parameters within normal operating specifications. Indoor inspection revealed a MERV 16 filter that had been in service since June 2025, exceeding recommended replacement intervals; provided guidance on proper filter sourcing and replacement schedule. Replaced humidifier pad as part of routine maintenance and confirmed UV bulb replacements have been ordered by homeowner. Verified evaporator drain line is clear and draining properly with no blockages present. All system components tested and operating within manufacturer specifications at time of service. Fall furnace inspection scheduled for heating season preparation.