Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 24, 2026.
Hurlburt Heating & Plumbing has completed 3,581 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to no hot water complaint and determined the original 40-gallon natural gas water heater had reached end of life and required replacement. Removed existing failed unit and installed new Bradford White 40-gallon natural gas water heater. Connected hot and cold water supply lines with proper brass fittings, installed pressure relief valve with discharge piping, and attached galvanized vent pipe for proper exhaust ventilation. Verified all connections for leaks, tested unit operation, and confirmed hot water delivery. Installation completed in unfinished utility area with all plumbing connections secured and system fully operational.
Performed camera inspection of main sewer line in response to toilet leak causing flooding in bathroom and basement. Inspection revealed significant root intrusion with balls of roots obstructing the sewer line. Cleared blockage using rigid cable machine to restore proper drainage and flow.
Installed a Honeywell Home ProSeries T4 programmable thermostat to replace the existing unit. Removed the old thermostat, mounted and leveled the new wall plate, connected the wiring, and secured the new thermostat to the wall. Verified proper operation of heating, cooling, and fan modes upon completion.
Completed annual maintenance on a 5-year-old Lennox EL296 two-stage gas furnace. Verified proper operation of hot surface igniter, flame sensor, capacitor, and gas pressure. Removed and inspected gas manifold, confirming burners were clean and free of debris. Test-fired unit and confirmed proper operation in both stage one and stage two heating modes. Inspected blower wheel and verified cleanliness. Resecured loose return ductwork to prevent air leakage. Flushed condensate trap with 40 oz of water, clearing minor debris accumulation through drain line. Identified non-operational UV bulb requiring replacement, which homeowner will provide. Advised homeowner has ordered new MERV 16 filters for installation. All systems operating within manufacturer specifications with no additional issues found at time of service.
Performed comprehensive cooling maintenance on a Lennox air conditioner installed approximately one year ago. Tested the dual run capacitor rated at 35/5 µF, which measured 35.1/5 µF and is operating within acceptable parameters. Verified refrigerant charge levels are correct with no adjustments needed. Cleaned heavily debris-packed condenser coil using soap and water to restore proper airflow and heat transfer efficiency. Replaced the 25 x 20 x 1 air filter with a new unit. Conducted operational testing of the complete system to verify proper cooling performance. All components are functioning as designed and the system is cooling effectively. Unit is ready for continued service.
Responded to repair request for HVAC drain pan replacement. Upon inspection, discovered three cracks in the existing drain pan that were causing water leakage. Removed the damaged drain pan and installed a new replacement unit. Performed thorough water testing on the newly installed drain pan to verify proper water retention and drainage functionality. Confirmed all water flows correctly through the drain system without leakage. Job required two technicians due to equipment access and positioning requirements.
Responded to a no hot water complaint affecting the entire residence. Upon arrival, diagnosed an electric water heater with a tripped breaker and failed lower thermostat causing inadequate water heating. Reset the breaker and tested both upper and lower thermostats to confirm malfunction. Replaced both the upper and lower thermostats as a preventative measure to ensure reliable operation and restore full hot water capacity to the home.
Responded to main floor bathroom drainage issues affecting both shower and sink fixtures. Removed significant accumulation of hair from bathtub drain and cleared heavy buildup of organic debris from bathroom sink drain. Performed thorough cleaning of both drain assemblies and conducted extensive water flow testing to verify proper drainage restoration and confirm blockages were completely eliminated.
Completed comprehensive air conditioning tune-up and maintenance service on Lennox condenser unit. Performed standard seasonal maintenance procedures including system inspection, cleaning, and performance verification as outlined in maintenance agreement protocol.
Responded to return visit for frozen air conditioning system approximately one year after installation. Connected manifold gauges and placed unit in charge mode to diagnose issue. Discovered severely leaking Schrader core on liquid line service port that was dripping refrigerant, which was replaced. Verified refrigerant charge levels were within proper range after core replacement. Adjusted airflow and dehumidification settings that had been modified during previous visit, which likely contributed to freezing condition. Recommended installing discharge air temperature sensor if freezing issues persist.
Responded to emergency call for reported toilet leak causing flooding in bathroom and basement of 80-year-old residence. Upon arrival, conducted thorough inspection of all bathroom fixtures including toilet, sink, tub, and shower. Performed water flow tests on each fixture while monitoring basement area for active leaks or water intrusion. No active leaks were detected during inspection period. Unable to replicate reported flooding conditions at time of service call.
Completed preventive maintenance on residential furnace system per maintenance agreement. Performed comprehensive inspection of all mechanical and electrical components, including blower motor assembly, control boards, wiring connections, and PVC condensate drainage system. Cleaned routine components, verified all operational parameters within manufacturer specifications, and confirmed proper system operation with no deficiencies noted.
Completed comprehensive annual maintenance on both air conditioning and furnace systems, both approximately one year old. Performed thorough preventive maintenance on furnace unit, including inspection and cleaning of all routine components such as burners, heat exchanger, blower assembly, and flame sensor. Verified proper operation of gas valve, ignition system, and safety controls. All measurements and operational parameters found to be within manufacturer specifications. Conducted visual inspection of condensing unit that was serviced during previous AC maintenance in July. Both HVAC systems operating efficiently with no issues identified.
Responded to a callback for a Moen shower valve with a loose cartridge causing the handle to drift from the vertical position to full hot on its own, resulting in temperature fluctuations. Initially attempted replacement with a new cartridge, which exhibited the same issue due to excess factory grease on the internal barrel component. Resolved the problem by removing the barrel from the cartridge, wiping off the excess grease, and reinstalling, which restored proper friction and handle stability.
Responded to basement water leak occurring when air conditioning system was in operation. Upon inspection, identified severely corroded cast iron drain pipe under basement stairs with visible hole causing water discharge. Extensive rust damage and deterioration observed on cast iron plumbing connections and fittings. Documented condition of compromised piping system with photographs showing advanced corrosion on metal components and deteriorated pipe connections. Customer also reported water pooling in basement after using kitchen and bathroom sinks, consistent with failed drain line. Advised customer of need for cast iron pipe replacement due to extent of deterioration and recommended obtaining estimate for complete cast iron repipe to address systemic corrosion issues throughout drainage system.
Responded to kitchen drain backup issue where water was backing up through pipe under sink during use. Successfully cleared clogged kitchen drain by running snake through drainage system to remove obstruction. Documented existing plumbing configuration including PVC drainage pipes, coupling connections, and insulated supply lines in crawlspace area beneath sink for service records.
Completed routine furnace tune-up and preventative maintenance inspection as part of recurring heating system service agreement. Performed comprehensive system evaluation including safety checks, combustion analysis, and component testing. All equipment operating within normal parameters with no deficiencies identified; detailed findings documented on service form.
Completed scheduled air conditioning tune-up on 7-year-old Goodman cooling system as part of annual maintenance agreement. Performed comprehensive inspection of outdoor condenser unit including cleaning of coils, verification of refrigerant levels, electrical connections check, and assessment of overall system operation. Unit found to be in satisfactory working condition with all components functioning within normal parameters.
Responded to main sewer line backup in basement. Located blockage at 28 feet in main line and cleared obstruction using professional drain cleaning equipment. Performed video camera inspection of line after cleaning to verify complete clearance and assess pipe condition. Customer able to resume normal use of plumbing system.
Completed comprehensive furnace and air conditioning tune-up on residential HVAC system. Performed full system inspection, washed outdoor condenser unit, and tested all electrical components on both heating and cooling equipment. Identified failing capacitor on AC unit requiring replacement and provided repair estimates to address this issue, with both systems currently operational.