Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 25, 2026.
Hurlburt Heating & Plumbing has completed 3,581 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to no cooling complaint on 5-year-old unit experiencing evaporator coil freezing. Diagnosed system as low on R-410A refrigerant, indicating a leak in the system. Discussed findings and repair options with homeowner, who authorized refrigerant recharge with UV dye for future leak detection. Added 2 pounds of R-410A refrigerant and fluorescent dye to system. Verified proper system operation with 15-degree temperature split across evaporator coil. Provided estimates for comprehensive leak repair services. System restored to normal cooling operation.
Responded to a bathtub drain obstruction causing slow drainage and complete backup. Successfully cleared the blockage by snaking the drain line and removing the drum trap assembly. Normal drainage flow was restored to the tub/shower fixture.
Responded to a water leak complaint where the basement PVC drain pipe was dripping when the main floor toilet was flushed. Upon inspection, determined the toilet was leaking due to a failed wax ring seal at the base. Removed and reset the toilet with a new wax ring, eliminating the leak and restoring proper drainage function.
Completed routine plumbing inspection for recurring service member. Performed comprehensive system evaluation, finding all fixtures and components in excellent, like-new condition. Serviced reverse osmosis water filtration system by replacing all three filters per manufacturer's maintenance schedule for unit installed approximately one year prior.
Responded to a bathroom lavatory drain issue where standing water remained in the sink following customer's P-trap cleaning attempt. Upon arrival, diagnosed a plugged lavatory drain line beyond the P-trap assembly. Utilized drain snake equipment to clear the obstruction in the lavatory pipe, restoring proper drainage function. Verified drain plug assembly was correctly installed and tested system to confirm water flow was operating normally with no standing water remaining in the fixture.
Completed comprehensive plumbing inspection of residential property, examining all accessible plumbing systems, fixtures, and components. Inspected utility closet mechanical space containing water heater or expansion tank with proper wall-mounted securing straps, verified multiple supply and drainage lines including flexible hoses and rigid piping with brass fittings for proper installation and connections. Evaluated exposed plumbing infrastructure in unfinished wall cavity, including vertical PVC drainage pipe with appropriate hangers and supports through insulated stud bays. All findings documented with photographic evidence for service records.
Completed heating system preventive maintenance on newer furnace found in good operating condition. Performed comprehensive tune-up including inspection of all components, combustion analysis, and safety checks with no deficiencies identified. Documented frost accumulation observed on flexible ductwork in confined space, indicating potential insulation or airflow concerns that may require future attention.
Responded to plumbing service call for water leak in master bathroom tub drain and loose faucet fixtures throughout the residence. Upon inspection, determined that the existing putty seal on the tub drain had deteriorated and failed, causing visible water leakage. Removed old putty material and applied fresh silicone sealant to the tub drain assembly to create a watertight seal. Additionally, addressed multiple loose widespread faucet installations in both the master bathroom and lower level bathroom, including loose mounting hardware and misaligned handles. Tightened all faucet components, realigned handles for proper operation, and secured mounting hardware on all affected fixtures. Tested all repairs to ensure proper function and verified leak resolution.
Completed scheduled bi-annual preventive maintenance on commercial rooftop HVAC unit. Replaced eight 20x20x2 filters and installed new A48 belt per maintenance agreement specifications. Cleaned routine components, cleared and repaired blocked condensate drain line to restore proper drainage function. Unit tested and operating within normal parameters upon completion.
Responded to a leaking kitchen sink drain caused by severely deteriorated galvanized piping. The galvanized pipe connecting the kitchen sink drain to the branch drain had disintegrated and was heavily pitted with rust corrosion. Removed several feet of failed cast iron and galvanized pipe from the basement area. Installed new PVC waste line routed through the bottom of the kitchen sink cabinet, establishing proper connection to the kitchen sink drain and existing drainage system. New installation includes PVC P-trap configuration under double sink basin, ensuring proper drainage and long-term reliability. All affected piping replaced with code-compliant PVC materials to prevent future corrosion issues.
Completed annual air conditioning tune-up on 3-year-old Lennox condenser unit as part of maintenance agreement. Performed comprehensive inspection and preventive maintenance procedures per manufacturer specifications, including cleaning condenser coils, checking refrigerant levels, testing electrical components, and verifying proper system operation. Unit found to be in good working condition with no deficiencies noted.
Responded to slow draining bathroom sink. Upon inspection, found drain line heavily obstructed with accumulated buildup of hair, soap residue, and organic matter. Cleared blockage using appropriate drain cleaning equipment and restored proper drainage flow. Tested system to verify complete water evacuation and proper drain function. Advised property owner that drain line shows significant wear and recommended scheduling estimate for potential pipe replacement as part of planned bathroom remodeling project.
Completed comprehensive AC tune-up on Trane outdoor condensing unit. Performed full system inspection including blower motor, evaporator coil verification, and drainage system check—all components found clean and functioning properly. Conducted electrical testing on outdoor unit with all readings within manufacturer specifications. Cleaned condenser coil and ran operational test for 15 minutes, confirming proper system performance with temperature split exceeding 20 degrees across the evaporator. Customer reported no concerns and confirmed recent filter replacement. System operating efficiently with no deficiencies noted. Recommended continuing routine preventive maintenance schedule.
Performed comprehensive maintenance on 2006 Lennox R-22 split air conditioning system and matching gas furnace. Upon arrival, found outdoor condenser coil 100% blocked with cottonwood and debris, severely restricting heat rejection and causing abnormal operating pressures. Thoroughly cleaned condenser coil, removing all obstructions. After cleaning, system returned to normal operation with measured subcooling stabilizing between 4.9°F and 5.6°F, matching manufacturer specification of 5°F target. Conducted full furnace inspection and testing. Verified igniter, pressure switches, burners, and flame sensor all operating within specification. Confirmed ECM blower motor functioning properly. Noted system equipped with variable-speed blower technology. Observed visible wear and discoloration on multiple areas of heat exchanger; while not currently affecting operation, these areas require monitoring on future service visits due to potential safety concerns. Homeowner reported water dripping
Completed comprehensive plumbing inspection of residential property, including thorough evaluation of automatic storage natural gas water heater and associated plumbing connections. Documented all findings with photographic evidence, verified proper installation of copper supply lines and overhead plumbing infrastructure, confirmed presence of required safety equipment including wall-mounted fire extinguisher, and assessed overall system functionality and code compliance.
Completed comprehensive furnace tune-up on residential heating system, including full inspection per maintenance agreement protocol. Replaced defective collector box and gas valve to ensure safe and efficient operation. Documented equipment make, model, and serial number information with clear photographs for service records.
Responded to a reported water leak from the side of a powder bathroom toilet during flushing. Upon inspection, identified a failed tank-to-bowl gasket on a Kohler toilet as the source of the leak. Replaced the defective gasket with a new tank-to-bowl seal and securely tightened all water supply line fittings to ensure proper connections and prevent future leaks.
Responded to callback for floor drain flooding issue. Upon inspection, confirmed floor drain was not actively backed up at time of arrival. Identified that drainage pipe has improper pitch/back-pitch condition near sewer tank, causing recurring drainage problems. Advised customer that excavation and repitching of affected pipe section will be required to permanently resolve the issue.
Completed comprehensive HVAC maintenance agreement service including air conditioning and furnace tune-up. Performed thorough inspection of outdoor condenser unit, cleaning exterior coils and removing debris to ensure optimal airflow and heat transfer efficiency. Replaced air filter in furnace system with customer-provided filter to maintain proper indoor air quality and system performance. Conducted complete electrical testing on both heating and cooling systems, verifying all voltage readings, amperage draws, and connections are within manufacturer specifications. Washed down outdoor AC unit to remove accumulated dirt and debris from condenser coils. Verified proper operation of both furnace and air conditioning systems with all components functioning normally and no deficiencies noted. All equipment operating as designed with no repairs required at this time.
Completed comprehensive plumbing inspection of residential bathroom fixtures as part of family rewards program. Examined sink vanity area including chrome single-handle faucet, drain assembly, and under-sink plumbing connections including supply lines and P-trap configuration. All components found to be functioning properly with no visible leaks or drainage issues detected.